PubMed Health⌕ Search

Biomedical subjects

N J Dunne

Publications and source records attributed to N J Dunne.

10 recordsLinked to original sources

Validation of the small-punch test as a technique for characterizing the mechanical properties of acrylic bone cement.

This paper examines the validity of using the small-punch test technique as a means of quantifying the mechanical properties of acrylic bone cement under different test conditions. The elastic moduli calculated using the small-punch test method were compared with data measured using the international standard for acrylic bone resin, ISO 5833. Conclusions from the study indicate that the small-punch test is a reproducible miniature specimen test method that can be used to characterize the mechanical properties of retrieved acrylic bone cement as used in total joint replacement surgery. Moreover, the test conditions were found to influence the elastic modulus of acrylic bone cement. The test temperature had a greater effect on the elastic behaviour of the bone cement than the test medium.

Bone Cements↗

Assessment of cement introduction and pressurization techniques.

The objective of this study was to measure the medullary pressures generated during bone cement injection, pressurization and femoral prosthesis insertion. The measurements were recorded throughout the length of an in vitro femoral model while implanting a series of prosthetic hip stems using different pressurization techniques. The prostheses used were a Charnley 40 flanged stem (Johnson & Johnson DePuy International Limited), an Exeter No. 3 stem (Stryker Howmedica Osteonics, Howmedica International Limited), and a customized femoral component (Johnson & Johnson DePuy International Limited). The following parameters were derived from the pressure data recorded: peak pressure, decay pressure and duration above optimum pressure of 76 kPa to predict adequate penetration. The custom and Exeter stems generated cement pressures throughout the length of the cavity model that were predicted to achieve adequate bone cement interdigitation into cancellous bone. For all the conditions investigated in this study, when using the Charnley femoral component, an adequate level of cement pressurization was generated in the medial-distal portion of the femoral cavity. It is postulated that this could result in reduced integration of the cement mantle with bone and less effective transmission of functional loads applied during a patient's normal activity, postoperatively.

Arthroplasty, Replacement, Hip↗

The relationship between porosity and fatigue characteristics of bone cements.

In this study, the fatigue strengths of acrylic cement prepared by various commercially available reduced pressure mixing systems were compared with the fatigue strength of cement mixed by hand (control) under atmospheric conditions. The following observations were made from this investigation. The mean fatigue strength of reduced pressure mixed acrylic bone cement is double that of cement mixed by hand using an open bowl, 11,354+/-6,441 cycles to failure for reduced pressure mixing in comparison with 5,938+/-3,199 cycles for mixing under atmospheric conditions. However, the variability in mean fatigue strengths of reduced pressure mixed bone cement is greater for some mixing devices. The variation in fatigue strengths for the different mixing techniques is explained by the different porosity distributions. The design of the reduced pressure mixing system and the technique employed during mixing strongly contribute to the porosity distribution within the acrylic bone cement. The level of reduced pressure applied during cement mixing has an effect on the fatigue strength of bone cement, but the mixing mechanism is significantly more influential.

Biocompatible Materials↗

Shrinkage stresses in bone cement.

Shrinkage of bone cement is reported primarily as a consequence of polymerisation, however thermal shrinkage also occurs as a result of its exothermic reaction. It is proposed that the latter effect is important, since it occurs late in the curing cycle at a time when the cement has attained its mechanical properties as a solid, and that residual stresses result. Observations from experiments and literature reports suggest that residual stresses may be sufficient to initiate cracks at the interface between hip replacement stems and cement.A theoretical model has been developed to calculate interference stresses, using thick-walled cylinder theory, on the basis of thermal and total shrinkages. Thermal shrinkage values were calculated using the coefficient of linear thermal expansion of bone cement, while total shrinkages were measured. Moduli of elasticity values were measured for acrylic bone cements ranging from 2.1 to 2.7GPa, as were Poisson's ratio values ranging from 0.38 to 0.46. Theoretical calculation of stresses in a cement mantle, based on assumptions of thermal shrinkage alone, predicted circumferential stresses of 8.4-25.2MPa for cement curing temperatures in the range 60-140 degrees C. It is concluded that cracks observed around hip prosthesis stems in laboratory specimens of bone cement are due to shrinkage and that residual stresses are sufficient to cause crack initiation prior to functional loading.

Bone Cements↗

Fracture characteristics of acrylic bone cement-bone composites.

In this study, the fracture properties of Perspex, acrylic bone cement prepared using a commercially available reduced pressure mixing system and a bone cement-bone composite were compared under different test conditions. The method used was the double-torsion (DT) test. The observations made from this investigation are as follows. The fracture toughness and critical crack length for Perspex significantly increased (ANOVA, p = 0.001) when tested in water compared to air. An increase in test temperature from 19 to 37 degrees C resulted in a decrease in the fracture properties in water, this reduction being also statistically significant (ANOVA, p = 0.02). The mean fracture toughness and standard deviation of CMW3 bone cement when mixed under reduced pressure was 2.19 +/- 0.11 MN m(-3/2) compared to 3.89 +/- 0.10 MN m(-3/2) for the cement-bone composite (ANOVA, p = 0.004). The crack length determined for CMW3 bone cement and the cement bone composite were 0.323 +/- 0.031 and 1.1434 +/- 0.61 mm respectively. The plateau loads of the composite material were higher than measured for the monolithic acrylic bone cement, 249.66 +/- 67.75 N compared with 140.83 +/- 6.82 N. The high level of variation recorded for the plateau loads of the bone cement bone composite is due to the orientation and volume fraction of the cancellous bone. It can be concluded from this investigation that acrylic bone cement interdigitation into the cancellous bone results in a superior material with respect to crack resistance in comparison with the bone cement as a lone entity. Therefore it is an advantage if there is sufficient cancellous bone stock available within the intermedullary canal to allow bone cement penetration to occur, for the transfer of loads during daily activity. Additionally, it is paramount that the clinician ensures that adequate pressure is applied and maintained for an appropriate time during cement injection and prosthesis insertion in order to ensure optimum cement penetration into the pore openings of the cancellous bone, thus improving the resistance of the cement mantle to fracture and ultimately improving the longevity of the joint replacement.

Animals↗

Curing characteristics of acrylic bone cement.

Commercial acrylic bone cements are supplied as two components, a polymer powder and a liquid monomer. Mixing of the two components is followed by a progressive polymerization of the liquid monomer to yield a solid mass, a high level of heat being generated during this exothermic reaction. The exposure of bone to high temperatures has led to incidences of bone necrosis and tissue damage, ultimately resulting in failure of the prosthetic fixation. The aim of this study was to determine the thermal properties of two acrylic bone cements as they progress through their polymerization cycles. It was also felt that there was a need to quantify the variations in the curing characteristics as a function of preparing bone cement by different techniques, hand mixing and vacuum mixing. A number of parameters were calculated using the data gathered from the investigation: peak temperature, cure temperature, cure time, and the cumulative thermal necrosis damage index. The results show the temperature profile recorded during polymerization was lowest when the cement was prepared using the Howmedica Mix-Kit I system: 36 degrees C for Palacos R and 41 degrees C for CMW3 respectively. When the acrylic cements were prepared in any vacuum mixing system there was evidence of an increase in the cure temperature. The main factor that contributed to this rise in temperature was an imbalance in the polymer powder : liquid monomer ratio, there was a high incidence of unmixed powder visible in the mixing barrel of some contemporary vacuum mixing devices. Observing the thermal characteristics of the polymethyl methacrylate (PMMA) bone cements assessed, it was found that particular formulations of bone cements are suited to certain mixing methodologies. It is vital that a full investigation is conducted on a cement mixing/delivery system prior to its introduction into the orthopaedic market.

Journal Article↗

Influence of mixing techniques on the physical properties of acrylic bone cement.

Palacos R bone cement was prepared using three commercially available mixing techniques, first generation, second generation and third generation, to determine the mechanical properties and porosity contents of the bone cement. The compressive strengths, bending strengths and flexural moduli were expressed as a function of void content. The volume of pores within the cement structure was found to be a contributing factor to the physical properties of acrylic bone cement. The lower the volume of voids in the cement the better the compressive and flexural properties, hence stronger bone cement. It was found that the best results were obtained from cement that had been mixed using the Mitab Optivac or Summit HiVac Syringe systems at a reduced pressure level of between -72 and -86 kPa below atmospheric pressure, resulting in cement of porosity 1.44-3.17%; compressive strength 74-81 MPa; flexural modulus 2.54-2.60 GPa; and flexural strength 65-73 MPa.

Acrylates↗

Development of a computer model to predict pressure generation around hip replacement stems.

Cemented fixation of hip replacements is the elective choice of many orthopaedic surgeons. The cement is an acrylic polymer which grouts the prostheses into the medullary cavity of the femur. Cement pressure is accepted as a significant parameter in determining the strength of cement/bone interfaces and hence preventing loosening of the prostheses. The aim of this work was to allow optimal design of the intramedullary stem of a hip prosthesis through knowledge of the flow characteristics of curing bone cement which can be used to predict pressures achieved during insertion of the femoral stem. The viscosity of the cement is a vital property determining the cement flow and hence cement interdigitation into bone. The apparent viscosities, nu(a), of three commercial bone cements were determined with respect to time by extrusion of the curing cement through a parallel die of known geometry under selected pressures. Theoretical models were developed and implemented in a computer program to describe cement flow in three models each of increasing complexity: (a) a simple parallel cylinder, (b) a tapered conical mandrel and (c) an actual femoral prosthesis, the latter models being complicated by extensional effects as annular areas increase. Predicted pressures were close to those measured experimentally, maximum pressures being in the range 10-160 kPa which may be compared with a threshold of 76 kPa proposed for effective interdigitation with cancellous bone. The theoretical model allows the prosthesis/bone geometry of an individual patient to be evaluated in terms of probable pressure distributions in the medullary cavity during cemented fixation and can guide stem design with reference to preparation of the medullary canal. It is proposed that these models may assist retrospective studies of failed components and contribute to implant selection, or to making informed selection from options in custom hip prosthesis designs to achieve optimum cement pressurization.

Bone Cements↗

Flow characteristics of curing polymethyl methacrylate bone cement.

During polymerization, polymethyl methacrylate bone cements have complex viscoelastic characteristics. Within a short working time they transform from dough-like consistencies to solid cements. Therefore, the time at which a cement is introduced to cancellous bone surfaces and subjected to pressure is important, to achieve optimum flow and mechanical interdigitation. Achieving adequate mechanical interlock increases the area for load transfer and reduces localized bone-cement interface stresses. The aim of this study was to measure the flow characteristics for commercial bone cements as a function of time and calculate the apparent viscosities for the curing bone cements. The capillary extrusion method was used to measure the rate of flow of the curing cement, by means of a melt flow index apparatus, which was manufactured in-house. The tests were conducted using nozzles of different lengths and under two loads. This enabled the power index value, n, and the pressure at the die entry, P0, to be calculated for each material with respect to time. Once the flow characteristics were determined, a series of formulae were used to calculate the shear rates, gamma, the shear stresses, tau, and the apparent viscosities, eta a, of the curing bone cements. The results indicated that acrylic bone cements are non-Newtonian, pseudoplastic materials, since the power index values are less than 1.0 during the curing stage. The consistency indices, K, were calculated from the shear stress versus shear rate data. The apparent viscosities of the cements were found to increase with respect to increases in time. Clinically, it was considered desirable to inject and pressurize the cement into the medullary canal while its viscosity is relatively low in order to obtain maximum interdigitation into cancellous bone, provided adequate containment and a means of pressurization can be achieved. The pseudoplastic character of bone cements is responsible for their reduction in viscosity with increased shear rate, a property that may be exploited to enhance penetration with appropriate delivery.

Biocompatible Materials↗

Modelling medical devices: the application of bioengineering in surgery.

Medical device technology has an increasingly important role in surgical procedures. In this article, five case studies of bioengineering in surgery are described as follows: computer-aided design of vascular grafts; middle-ear prostheses; hip prosthesis stems for optimal cement pressurisation; prototype development of a device for measurement of abdominal sounds for monitoring digestive tract activity and a hand-access device for laparoscopic surgery. In each case, new bioengineering design methodologies are demonstrated. The general principles underlying the application of bioengineering in surgery are discussed.

Arthroplasty, Replacement, Hip↗