Differential lymphocyte reactivity to serum-derived metal-protein complexes produced from cobalt-based and titanium-based implant alloy degradation.

The lymphocyte response to serum protein complexed with metal from implant alloy degradation was investigated in this in vitro study using primary human lymphocytes from healthy volunteers (n = 10). Cobalt chromium molybdenum alloy (Co-Cr-Mo, ASTM F-75) and titanium alloy (Ti-6Al-4V, ASTM F-136) beads (70 microm) were incubated in agitated human serum at 37 degrees C to simulate naturally occurring metal implant alloy degradation processes. Particulate free serum samples that had been incubated with metal were then separated into molecular weight based fractions. The amounts of soluble Cr and Ti within each serum fraction were measured and correlated with lymphocyte proliferation response to the individual serum fractions. Lymphocytes from each subject were cultured with 11 autologous molecular weight based serum fractions either with or without added metal. Two molecular weight ranges of human serum proteins were associated with the binding of Cr and Ti from Co-Cr-Mo and Ti implant alloy degradation (at <30 and 180-250 kDa). High molecular weight serum proteins ( approximately 180 kDa) demonstrated greater lymphocyte reactivity when complexed with Cr alloy and Ti alloy than low (5-30 kDa) and midrange (30-77 kDa) serum proteins. When the amount of lymphocyte stimulation was normalized to both the moles of metal and the moles of protein within each fraction (metal-protein complex reactivity index), Cr from Co-Cr-Mo alloy degradation demonstrated approximately 10-fold greater reactivity than Ti in the higher molecular weight serum proteins ( approximately 180 kDa). This in vitro study demonstrated a lymphocyte proliferative response to both Co-Cr-Mo and Ti alloy metalloprotein degradation products. This response was greatest when the metals were complexed with high molecular weight proteins, and with metal-protein complexes formed from Co-Cr-Mo alloy degradation.

Absorbable Implants↗

The potential role of the osteoblast in the development of periprosthetic osteolysis: review of in vitro osteoblast responses to wear debris, corrosion products, and cytokines and growth factors.

Limited information is available on the responses of osteoblasts to wear debris, corrosion products, and cytokines and on the roles of altered osteoblast functions in the development of periprosthetic bone loss. Wear debris-challenged osteoblasts exhibit altered functions resulting in the loss of their capacity to produce bone matrix and to replace the resorbed bone. Also, osteoblasts may secrete cytokines, which act in a paracrine fashion to recruit inflammatory cells into the periprosthetic space and to stimulate osteoclastic bone resorption. These effects may be mediated in part by ionic metal dissolution products. We review the mechanisms by which altered osteoblast functions, in response to particulate wear debris, corrosion products, and cytokines and growth factors, may contribute to the development and the progression of periprosthetic osteolysis.

Corrosion↗

Evaluation of metallic and polymeric biomaterial surface energy and surface roughness characteristics for directed cell adhesion.

Directed cell adhesion remains an important goal of implant and tissue engineering technology. In this study, surface energy and surface roughness were investigated to ascertain which of these properties show more overall influence on biomaterial-cell adhesion and colonization. Jet impingement was used to quantify cellular adhesion strength. Cellular proliferation and extracellular matrix secretion were used to characterize colonization of 3T3MC fibroblasts on: HS25 (a cobalt based implant alloy, ASTM F75), 316L stainless steel, Ti-6Al4V (a titanium implant alloy), commercially pure tantalum (Ta), polytetrafluoroethylene (PTFE), silicone rubber (SR), and high-density polyethylene (HDPE). The metals exhibited a nearly five-fold greater adhesion strength than the polymeric materials tested. Generally, surface energy was proportional to cellular adhesion strength. Only polymeric materials demonstrated significant increased adhesion strength associated with increased surface roughness. Cellular adhesion on metals demonstrated a linear correlation with surface energy. Less than half as much cellular proliferation was detected on polymeric materials compared to the metals. However the polymers tested demonstrated greater than twice the amount of secreted extracellular matrix (ECM) proteins on a per cell basis than the metallic materials. Thus, surface energy may be a more important determinant of cell adhesion and proliferation, and may be more useful than surface roughness for directing cell adhesion and cell colonization onto engineered tissue scaffoldings.

3T3 Cells↗

Osteolysis: basic science.

Since the recognition of aseptic loosening by Charnley in the early 1960s, much information has been gained on the basic science of periprosthetic bone loss. Initially termed cement disease, it now generally is accepted that, in most instances, osteolysis is a manifestation of an adverse cellular response to phagocytosable particulate wear and corrosion debris, possibly facilitated by local hydrodynamic effects. Tissue explant, animal, and cell culture studies have allowed us to compile an appreciation of the complexity of cellular interactions and chemical mediators involved in osteolysis. Cellular participants have been shown to include the macrophage, osteoblast, fibroblast, and osteoclast. The plethora of chemical mediators that are responsible for the cellular responses and effects on bone include prostaglandin E2, tumor necrosis factor-alpha, interleukin-1, and interleukin 6. However, an increasing number of other proinflammatory and antiinflammatory cytokines, prostenoids, and enzymes have been shown to play important roles in this process. The ultimate goal of basic research is to develop novel strategies for evaluation and treatment of patients with osteolysis. Although initial animal studies are promising for possible pharmacologic treatment and prevention of osteolysis, well-controlled human trials are required before agents such as bisphosphonates can be recommended for general clinical use.

Animals↗

Orthopaedic implant related metal toxicity in terms of human lymphocyte reactivity to metal-protein complexes produced from cobalt-base and titanium-base implant alloy degradation.

Metal toxicity from sources such as orthopaedic implants was investigated in terms of immune system hyper-reactivity to metal implant alloy degradation products. Lymphocyte response to serum protein complexed with metal from implant alloy degradation was investigated in this in vitro study using primary human lymphocytes from healthy volunteers (n = 10). Cobalt chromium molybdenum alloy (Co-Cr-Mo, ASTM F-75) and titanium alloy (Ti-6Al-4V, ASTM F-136) beads (70 microm) were incubated in agitated human serum at 37 degrees Celsius to simulate naturally occurring metal implant alloy degradation processes. Particulate free serum samples, which were incubated with metal, were then separated into molecular weight based fractions. The amounts of soluble Cr and Ti within each serum fraction were measured and correlated with lymphocyte proliferation response to the individual serum fractions. Lymphocytes from each subject were cultured with 11 autologous molecular weight based serum fractions either with or without added metal. Two molecular weight ranges of human serum proteins were associated with the binding of Cr and Ti from Co-Cr-Mo and Ti implant alloy degradation (at < 30 and 180-330 kDa). High molecular weight serum proteins (approximately 180 kDa) demonstrated greater lymphocyte reactivity when complexed with metal released from Co-Cr-Mo alloy and Ti alloy than with low (5-30 kDa) and midrange (30-77 kDa) serum proteins. When the amount of lymphocyte stimulation was normalized to both the moles of metal and the moles of protein within each fraction (Metal-Protein Complex Reactivity Index, MPCRI), Cr from Co-Cr-Mo alloy degradation demonstrated approximately 10 fold greater reactivity than Ti in the higher molecular weight serum proteins (approximately 180-250 kDa). This in vitro study demonstrated a lymphocyte proliferative response to both Co-Cr-Mo and Ti alloy metalloprotein degradation products. This response was greatest when the metals were complexed with high molecular weight proteins, and with metal-protein complexes formed from Co-Cr-Mo alloy degradation.

Adult↗

Systemic metal-protein binding associated with total joint replacement arthroplasty.

The distribution of titanium [Ti] and chromium [Cr] in serum protein fractions of patients with and without total joint replacements containing Cr and Ti was studied. Three groups were evaluated: 10 patients with cobalt-chromium [CoCr] alloy prostheses and known elevated levels of Cr; 10 patients with Ti containing implants and known elevated levels of Ti; and 10 age matched controls without prostheses. Metal-protein binding was also examined by adding various concentrations of Cr(+3) (CrCl(3)) to control serum. Cr and Ti were bound to serum proteins within specific molecular weight ranges in both patient groups. Two molecular weight ranges were found to bind Cr (at approximately 70 and approximately 180 kDa) in patients with CoCr alloy prostheses, whereas a single molecular weight range (at approximately 70 kDa) was found to bind Ti in patients with Ti alloy implants. This metal-protein binding was reproduced in vitro by adding CrCl(3) at concentrations of approximately 100 and 1000 ppb Cr, which is orders of magnitude higher than that contained in the serum of patients with CoCr alloy implants ( approximately 3 ppb Cr). This suggests that protein binding is initiated in the periprosthetic space where metal concentrations are typically 2-3 orders of magnitude higher than that observed systemically in the serum. In vitro, high molecular weight proteins including immunoglobulins demonstrated the highest affinity to Cr. Determination of specific protein carriers of metal degradation products is an essential component in the assessment of the long-term biological affects of total joint replacement devices.

Adult↗

A triple assay technique for the evaluation of metal-induced, delayed-type hypersensitivity responses in patients with or receiving total joint arthroplasty.

The determination of biocompatibility has been dominated historically by the characterization of candidate materials based upon the observation of adverse host responses. However, some adverse responses are subtle in clinical settings and continue to foster debate and investigation. One of these responses is "metal allergy" or hypersensitivity to metallic biomaterials. Current methods used to diagnose hypersensitivity reactions, such as dermal patch testing and migration inhibition assays, are not well accepted in orthopedic practice as a means for the characterization of hypersensitivity to metallic joint-replacement components. An increasing need to resolve whether metal sensitivity may be a significant and/or predisposing factor for eliciting an over-aggressive immune response in patients with metallic implant components requires improved and standardized widespread study. Here we present three in vitro methodologies: (1) a proliferation assay, (2) cytokine analysis using ELISA, and (3) a migration inhibition assay. When in conjunction with one another, these assays may be used to more comprehensively quantify metal-induced hypersensitivity responses. Therefore, these methodologies are detailed with the intent of facilitating multi-center large-scale studies. In the following cases, a multi-assay approach for measuring the prevalence of delayed-type hypersensitivity in orthopedic patients shows the propensity to yield a more comprehensive and, therefore, more conclusive determination than currently employed patch testing or single assay techniques.

Adult↗

Metal release and excretion from cementless titanium alloy total knee replacements.

Concentrations of titanium, aluminum, and vanadium were measured in the serum and urine of patients with titanium alloy cementless primary total knee arthroplasty components. Patients were categorized in one of five groups. In Group 1, the patellar and tibial articulating surfaces were made of carbon fiber reinforced ultrahigh molecular weight polyethylene. In Group 2, the patellar and tibial surfaces were made of ultrahigh molecular weight polyethylene. In Group 3, the femoral titanium alloy articulating surface was nitrogen ion implanted with ultrahigh molecular weight polyethylene patellar and tibial articulating surfaces. Patients in Group 4 had failed patellar components, and Group 5 was comprised of age and gender matched control subjects without implants. Serum concentrations of titanium were approximately 50 times greater in patients with failed patellar components (Group 4) and approximately 10 times greater in patients with carbon fiber reinforced polyethylene bearing surfaces (Group 1) when compared with Groups 2 and 3 and the control subjects (Group 5). For aluminum and vanadium, no detectable differences were observed among any of the groups. In addition, analysis of 24-hour urine samples showed no significant differences in titanium, aluminum, or vanadium concentrations among any of the groups. Elevated serum titanium levels may serve as a marker of patellar component failure or accelerated femoral component wear in total knee replacements with titanium alloy bearings. The toxicologic ramifications of these findings are unknown.

Aged↗

Metal release in patients who have had a primary total hip arthroplasty. A prospective, controlled, longitudinal study.

UNLABELLED: There is an increasing recognition that, in the long term, total joint replacement may be associated with adverse local and remote tissue responses that are mediated by the degradation products of prosthetic materials. Particular interest has centered on the metal-degradation products of total joint replacements because of the known toxicities of the metal elements that make up the alloys used in the implants. We measured the concentrations of titanium, aluminum, cobalt, and chromium in the serum and the concentration of chromium in the urine of seventy-five patients during a three-year prospective, longitudinal study. Twenty patients had had a so-called hybrid total hip replacement (insertion of a modular cobalt-alloy femoral stem and head with cement and a titanium acetabular cup without cement), fifteen had had insertion of an extensively porous-coated cobalt-alloy stem with a cobalt-alloy head and a titanium-alloy socket without cement, and twenty had had insertion of a proximally porous-coated titanium-alloy stem with a cobalt-alloy head and a titanium socket without cement. The remaining twenty patients did not have an implant and served as controls. The results of our study showed that, thirty-six months postoperatively, patients who have a well functioning prosthesis with components containing titanium have as much as a threefold increase in the concentration of titanium in the serum and those who have a well functioning prosthesis with cobalt-alloy components have as much as a fivefold and an eightfold increase in the concentrations of chromium in the serum and urine, respectively. The predominant source of the disseminated chromium-degradation products is probably the modular head-neck junction and may be a function of the geometry of the coupling. Passive dissolution of extensively porous-coated cobalt-alloy stems was not found to be a dominant mode of metal release. CLINICAL RELEVANCE: Increased concentrations of circulating metal-degradation products derived from orthopaedic implants may have deleterious biological effects over the long term that warrant investigation. This is a particularly timely concern because of recent clinical trends, including the reintroduction of metal-on-metal bearing surfaces and the increasing popularity of extensively porous-coated devices with large surface areas of exposed metal. Accurate monitoring of the concentrations of metal in the serum and urine after total hip replacement also can provide insights into the mechanisms of metal release. Our findings suggest that fretting corrosion at the head-neck coupling is an important source of metal release that can lead to increased concentrations of chromium in the serum. Determinations of the concentrations of metal in the serum and urine may be useful in the diagnosis of patients who are symptomatic after a total joint replacement as increased levels are indicative of at least one mode of mechanical dysfunction (for example, fretting corrosion) of the device.

Adult↗

Cell adhesion to biomaterials: correlations between surface charge, surface roughness, adsorbed protein, and cell morphology.

Adhesion of cells to a biomaterial surface can be a major factor mediating its biocompatibility. In this investigation, jet impingement techniques were used to quantify strength of cellular adhesion to various material surfaces. The metals tested: HS25 (a cobalt-based alloy similar to F75), 316L stainless steel, Ti-6Al-4V, and commercially pure tantalum, exhibited nearly a fivefold increase in adhesion strength above that characteristic of the polymeric materials tested (PTFE, silicone rubber, and HDPE). The present study examines physical and biological factors that might influence fibroblast adhesion to the biomaterial surface. The relation between surface charge and cellular adhesion was investigated in a controlled manner by measuring adhesion strength over a range of charge densities. The cells showed charge and electrical potential-dependent adhesion maxima, suggesting that surface alloying for optimum adherence may be possible. In a preliminary series of experiments adsorbed serum protein layers on a series of materials of differing adherence were investigated using gel electrophoresis to assess protein composition. Analysis of adsorbed proteins revealed little difference in relative abundance or total adsorption quantity. SEM micrographs of cells on Ti-6Al-4V and silicone rubber (high and low adhesion materials, respectively) demonstrated differences in cell morphology and cell density.

Biocompatible Materials↗