Visualization of hemodynamics in a silicon aneurysm model using time-resolved, 3D, phase-contrast MRI.

We performed time-resolved 3D phase-contrast MR imaging by using a 1.5T MR scanner to visualize hemodynamics in a silicon vascular model with a middle cerebral aneurysm. We ran an aqueous solution of glycerol as a flowing fluid with a pulsatile pump. Time-resolved images of 3D streamlines and 2D velocity vector fields clearly demonstrated that the aneurysm had 3D complex vortex flows within it during systolic phase. This technique provided us with time-resolved 3D hemodynamic information about the intracranial aneurysm.

Aged↗

Performance of a static-anode/flat-panel x-ray fluoroscopy system in a diagnostic strength magnetic field: a truly hybrid x-ray/MR imaging system.

Minimally invasive procedures are increasing in variety and frequency, facilitated by advances in imaging technology. Our hybrid imaging system (GE Apollo flat panel, custom Brand x-ray static anode x-ray tube, GE Lunar high-frequency power supply and 0.5 T Signa SP) provides both x-ray and MR imaging capability to guide complex procedures without requiring motion of the patient between two distant gantries. The performance of the x-ray tube in this closely integrated system was evaluated by modeling and measuring both the response of the filament to an externally applied field and the behavior of the electron beam for field strengths and geometries of interest. The performance of the detector was assessed by measuring the slanted-edge modulation transfer function (MTF) and when placed at zero field and at 0.5 T. Measured resonant frequencies of filaments can be approximated using a modified vibrating beam model, and were at frequencies well below the 25 kHz frequency of our generator for our filament geometry. The amplitude of vibration was not sufficient to cause shorting of the filament during operation within the magnetic field. A simple model of electrons in uniform electric and magnetic fields can be used to estimate the deflection of the electron beam on the anode for the fields of interest between 0.2 and 0.5 T. The MTF measured at the detector and the DQE showed no significant difference inside and outside of the magnetic field. With the proper modifications, an x-ray system can be fully integrated with a MR system, with minimal loss of image quality. Any x-ray tube can be assessed for compatibility when placed at a particular location within the field using the models. We have also concluded that a-Si electronics are robust against magnetic fields. Detailed knowledge of the x-ray system installation is required to provide estimates of system operation.

Electromagnetic Fields↗

Balanced phase-contrast steady-state free precession (PC-SSFP): a novel technique for velocity encoding by gradient inversion.

A technique for measuring velocity is presented that combines cine phase contrast (PC) MRI and balanced steady-state free precession (SSFP) imaging, and is thus termed PC-SSFP. Flow encoding was performed without the introduction of additional velocity encoding gradients in order to keep the repetition time (TR) as short as in typical SSFP imaging sequences. Sensitivity to through-plane velocities was instead established by inverting (i.e., negating) all gradients along the slice-select direction. Velocity sensitivity (VENC) could be adjusted by altering the first moments of the slice-select gradients. Disturbances of the SSFP steady state were avoided by acquiring different flow echoes in consecutively (i.e., sequentially) executed scans, each over several cardiac cycles, using separate steady-state preparation periods. A comparison of phantom measurements with those from established 2D-cine-PC MRI demonstrated excellent correlation between both modalities. In examinations of volunteers, PC-SSFP exhibited a higher intrinsic signal-to-noise ratio (SNR) and consequently low phase noise in measured velocities compared to conventional PC scans. An additional benefit of PC-SSFP is that it relies less on in-flow-dependent signal enhancement, and thus yields more uniform SNRs and better depictions of vessel geometry throughout the whole cardiac cycle in structures with slow and/or pulsatile flow.

Blood Flow Velocity↗

Analysis and generalized correction of the effect of spatial gradient field distortions in diffusion-weighted imaging.

Nonuniformities of magnetic field gradients can cause serious artifacts in diffusion imaging. While it is well known that nonlinearities of the imaging gradients lead to image warping, those imperfections can also cause spatially dependent errors in the direction and magnitude of the diffusion encoding. This study shows that the potential errors in diffusion imaging are considerable. Further, we show that retrospective corrections can be applied to reduce these errors. A general mathematical framework was formulated to characterize the contribution of gradient nonuniformities to diffusion experiments. The gradient field was approximated using spherical harmonic expansion, and this approximation was employed (after geometric distortions were eliminated) to predict and correct the errors in diffusion encoding. Before the corrections were made, the experiments clearly revealed marked deviations of the calculated diffusivity for fields of view (FOVs) generally used in diffusion experiments. These deviations were most significant farther away from the magnet's isocenter. For an FOV of 25 cm, the resultant errors in absolute diffusivity ranged from approximately -10% to +20%. Within the same FOV, the diffusion-encoding direction and the orientation of the calculated eigenvectors can be significantly altered if the perturbations by the gradient nonuniformities are not considered. With the proposed correction scheme, most of the errors introduced by gradient nonuniformities can be removed.

Anisotropy↗

Generalized reconstruction of phase contrast MRI: analysis and correction of the effect of gradient field distortions.

To characterize gradient field nonuniformity and its effect on velocity encoding in phase contrast (PC) MRI, a generalized model that describes this phenomenon and enables the accurate reconstruction of velocities is presented. In addition to considerable geometric distortions, inhomogeneous gradient fields can introduce deviations from the nominal gradient strength and orientation, and therefore spatially-dependent first gradient moments. Resulting errors in the measured phase shifts used for velocity encoding can therefore cause significant deviations in velocity quantification. The true magnitude and direction of the underlying velocities can be recovered from the phase difference images by a generalized PC velocity reconstruction, which requires the acquisition of full three-directional velocity information. The generalized reconstruction of velocities is applied using a matrix formalism that includes relative gradient field deviations derived from a theoretical model of local gradient field nonuniformity. In addition, an approximate solution for the correction of one-directional velocity encoding is given. Depending on the spatial location of the velocity measurements, errors in velocity magnitude can be as high as 60%, while errors in the velocity encoding direction can be up to 45 degrees. Results of phantom measurements demonstrate that effects of gradient field nonuniformity on PC-MRI can be corrected with the proposed method.

Blood Flow Velocity↗

Flow effects in balanced steady state free precession imaging.

An analysis of the effect of flow on 2D fully balanced steady state free precession (SSFP) imaging is presented. Transient and steady-state SSFP signal intensities in the presence of steady and pulsatile flow were simulated using a matrix formalism based on the Bloch equations. Various through-plane flow waveforms and rates were modeled numerically considering factors such as the excitation slice profile and both in- and out-flow effects. Phantom measurements in an experimental setup that allowed the assessment of SSFP signal properties as a function of frequency offset and flow rate demonstrated that the computer simulations provided a suitable description of the effects of flow in SSFP imaging. A volunteer scan was performed to provide in vivo validations. For accurate modeling of SSFP signal intensities it is crucial to include effects such as imperfect slice profiles and, more importantly, "out-of-slice" contributions to the signal. Both simulations and experiments show that there can be considerably large-frequency offset dependent-signal contributions from flowing spins that have already left the imaging slice but still add to the SSFP signal. Although spins leaving the slice do not experience additional RF-excitation, gradient activity is not confined to the region of excitations and the balanced nature of the SSFP imaging gradients allows "out-of-slice" transverse magnetization to contribute to the total SSFP signal, effectively by broadening the slice thickness for flowing spins. This results in a frequency dependence of in-flow related signal enhancement and flow artifacts.

Artifacts↗

First use of a truly-hybrid X-ray/MR imaging system for guidance of brain biopsy.

The use of a new hybrid imaging system for guidance of a brain biopsy is described. The system combines the strengths of MRI (soft-tissue contrast, arbitrary plane selection) with those of x-ray fluoroscopy (high-resolution real-time projection images, clear portrayal of bony structures) and allows switching between the imaging modalities without moving the patient. The biopsy was carried out using x-ray guidance for direction of the needle through the foramen ovale and MR guidance to target the soft-tissue lesion. Appropriate samples were acquired. The system could be particularly effective for guidance of those cases where motion, swelling, resection and other intra-operative anatomical changes cannot be accounted for using traditional stereotactic-based imaging approaches.

Adult↗

Effects of forced diving on the spleen and hepatic sinus in northern elephant seal pups.

In phocid seals, an increase in hematocrit (Hct) accompanies diving and periods of apnea. The variability of phocid Hct suggests that the total red cell mass is not always in circulation, leading researchers to speculate on the means of blood volume partitioning. The histology and disproportionate size of the phocid spleen implicates it as the likely site for RBC storage. We used magnetic resonance imaging on Northern elephant seals to demonstrate a rapid contraction of the spleen and a simultaneous filling of the hepatic sinus during forced dives (P < 0.0001, R(2) = 0.97). The resulting images are clear evidence demonstrating a functional relationship between the spleen and hepatic sinus. The transfer of blood from the spleen to the sinus provides an explanation for the disparity between the timing of diving-induced splenic contraction ( approximately 1-3 min) and the occurrence of peak Hct (15-25 min). Facial immersion was accompanied by an immediate and profound splenic contraction, with no further significant decrease in splenic volume after min 2 (Tukey-Kramer HSD, P = 0.05). At the conclusion of the dive, the spleen had contracted to 16% of its predive volume (mean resting splenic volume = 3,141 ml +/- 68.01 ml; 3.54% of body mass). In the postdive period, the spleen required 18-22 min to achieve resting volume, indicating that this species may not have sufficient time to refill the spleen when routinely diving at sea, which is virtually continuous with interdive surface intervals between 1 and 3 min.

Animals↗

A truly hybrid interventional MR/X-ray system: feasibility demonstration.

A system enabling both x-ray fluoroscopy and MRI in a single exam, without requiring patient repositioning, would be a powerful tool for image-guided interventions. We studied the technical issues related to acquisition of x-ray images inside an open MRI system (GE Signa SP). The system includes a flat-panel x-ray detector (GE Medical Systems) placed under the patient bed, a fixed-anode x-ray tube overhead with the anode-cathode axis aligned with the main magnetic field and a high-frequency x-ray generator (Lunar Corp.). New challenges investigated related to: 1) deflection and defocusing of the electron beam of the x-ray tube; 2) proper functioning of the flat panel; 3) effects on B0 field homogeneity; and 4) additional RF noise in the MR images. We have acquired high-quality x-ray and MR images without repositioning the object using our hybrid system, which demonstrates the feasibility of this new configuration. Further work is required to ensure that the highest possible image quality is achieved with both MR and x-ray modalities.

Brain↗

SMASH and SENSE: experimental and numerical comparisons.

Three parallel-imaging methods were implemented and compared in terms of artifact and noise content: original SMASH, Cartesian SENSE, and an extremely simple method called here the "scissors method." These methods represent very different approaches to the parallel-imaging problem. The experimental and numerical comparisons presented here aim at shedding light on the whole spectrum of parallel-imaging methods, not just the three methods actually implemented. In our results, SMASH images had an artifact level significantly higher than SENSE images for all acceleration factors. The SNR in SENSE images was nearly optimal at low acceleration factors. As acceleration was increased, the noise content in SENSE images eventually sharply departed from optimal values, while the artifact content remained low.

Artifacts↗

Truly hybrid interventional MR/X-ray system: investigation of in vivo applications.

RATIONALE AND OBJECTIVES: The purpose of this study was to provide in vivo demonstrations of the functionality of a truly hybrid interventional x-ray/magnetic resonance (MR) system. MATERIALS AND METHODS: A digital flat-panel x-ray system (1,024(2) array of 200 microm pixels, 30 frames per second) was integrated into an interventional 0.5-T magnet. The hybrid system is capable of MR and x-ray imaging of the same field of view without patient movement. Two intravascular procedures were performed in a 22-kg porcine model: placement of a transjugular intrahepatic portosystemic shunt (TIPS) (x-ray-guided catheterization of the hepatic vein, MR fluoroscopy-guided portal puncture, and x-ray-guided stent placement) and mock chemoembolization (x-ray-guided subselective catheterization of a renal artery branch and MR evaluation of perfused volume). RESULTS: The resolution and frame rate of the x-ray fluoroscopy images were sufficient to visualize and place devices, including nitinol guidewires (0.016-0.035-inch diameter) and stents and a 2.3-F catheter. Fifth-order branches of the renal artery could be seen. The quality of both real-time (3.5 frames per second) and standard MR images was not affected by the x-ray system. During MR-guided TIPS placement, the trocar and the portal vein could be easily visualized, allowing successful puncture from hepatic to portal vein. CONCLUSION: Switching back and forth between x-ray and MR imaging modalities without requiring movement of the patient was demonstrated. The integrated nature of the system could be especially beneficial when x-ray and MR image guidance are used iteratively.

Animals↗

Filtered backprojection for modifying the impulse response of circular tomosynthesis.

A filtering technique has been developed to modify the three-dimensional impulse response of circular motion tomosynthesis to allow the generation of images whose appearance is like those of some other imaging geometries. In particular, this technique can reconstruct images with a blurring function which is more homogeneous for off-focal plane objects than that from circular tomosynthesis. In this paper, we describe the filtering process, and demonstrate the ability to alter the impulse response in circular motion tomosynthesis from a ring to a disk. This filtering may be desirable because the blurred out-of-plane objects appear less structured.

Animals↗

Alignment of a volumetric tomography system.

A test-bed system has been developed for imaging phantoms with tomosynthesis and volumetric computed tomography. This system incorporates an amorphous silicon flat panel detector on a movable gantry and a computer-controlled rotational positioning stage. In this paper, an analysis of the sensitivity of reconstructed images to geometrical misalignment is presented. Application of this method to circular digital tomosynthesis is examined, with spatial resolution in the focal plane as the criterion for evaluating the effect of misalignment. A software-based method is presented for correcting data for imperfect system alignment prior to image reconstruction. Experimental results yield reconstructed images with spatial resolution approaching the theoretical limit based on detector pixel size and accounting for data interpolation.

Algorithms↗

Three-dimensional cardiac cine magnetic resonance imaging with an ultrasmall superparamagnetic iron oxide blood pool agent (NC100150).

The purpose of this study was to assess image quality of three-dimensional (3D) cardiac cine magnetic resonance (MR) imaging before and after administration of a T1-shortening ultrasmall superparamagnetic iron oxide blood pool agent (NC100150). 3D cardiac cine MR imaging was performed in 13 volunteers using a radiofrequency-spoiled cardiac-gated 3D cine gradient-echo sequence with short repetition and echo times. Compared with precontrast images, postcontrast images showed no enhancement in fat and skeletal muscle, moderate enhancement in myocardium, and significant enhancement in ventricular cavity. After contrast injection, the signal ratio of the ventricular chamber to the myocardium significantly increased, and dramatic improvements were seen in the quality of the cineangiographic images and the depiction of cardiac valves. This quantitative study has shown that 3D cardiac cine MR imaging using a blood pool agent provided MR ventriculography and cineangiography with excellent image quality.

Adult↗

A reduced field-of-view method to increase temporal resolution or reduce scan time in cine MRI.

In some dynamic applications of MRI, only a part of the field-of-view (FOV) actually undergoes dynamic changes. A class of methods, called reduced-FOV (rFOV) methods, convert the knowledge that some part of the FOV is static or not very dynamic into an increase in temporal resolution for the dynamic part, or into a reduction in the scan time. Although cardiac imaging is an important example of an imaging situation where changes are concentrated in a fraction of the FOV, the rFOV methods developed up to now are not compatible with one of the most common cardiac sequences, the so-called retrospective cine method. The present work is a rFOV method designed to be compatible with cine imaging. An increase by a factor n in temporal resolution or a decrease by n in scan time is obtained in the case where only one nth of the FOV is dynamic (the rest being considered static). Results are presented for both Cartesian and spiral imaging.

Animals↗

Depth-segmented detector for x-ray absorptiometry.

A new energy-dependent multi-cell detector, which is a generalization of the conventional front-back detector, was studied using computer simulations. The noise performance of the detector for bone quantitation was examined in comparison to an ideal energy discriminating detector, and front-back detectors with and without inter-detector filters. The front-back detectors were optimized for a reference object composed of water and bone, and then compared to the new detector over a range of object compositions. In this paper, precision in calculated bone thickness is used as the criterion for evaluating detector performance. Simulations show that the segmented detector always performs better than the front-back detector without an inter-detector filter. It outperforms the detector incorporating a filter by an amount that depends on the heterogeneity of the x-ray spectrum. In addition, for single component radiographic images, this multi-cell detector retains information which is lost in the front-back detector with a filter layer.

Absorptiometry, Photon↗

Partial fat-saturated contrast-enhanced three-dimensional MR angiography compared with non-fat-saturated and conventional fat-saturated MR angiography.

Abdominal three-dimensional magnetic resonance angiography was performed in 35 patients in the equilibrium phase without fat saturation, with conventional fat saturation, and with fast partial fat saturation. Qualitative and quantitative evaluation demonstrated significantly better vessel visualization with both fat-saturated techniques. The partial fat-saturated technique provided water-specific images within a breath hold, reducing motion artifacts significantly.

Abdomen↗

Three-dimensional motion tracking with volumetric phase contrast MR velocity imaging.

Motion tracking based on single-slice cine-phase contrast magnetic resonance imaging data has limitations. In the presence of nontrivial three-dimensional motion and deformation, volumetric data are necessary for accurate reconstruction of material point trajectories. A three-dimensional Fourier tracking method that uses volumetric data for motion tracking is presented. The method reconstructs a material point trajectory by computing its various harmonics. For any given temporal sampling rate, a frequency domain perspective of the tracking problem indicates that the method is accurate in estimating all reconstructible harmonics of a trajectory. The algorithm incorporates an intra-voxel linear spatial model into the integration to address potential tracking performance degradation due to possibly reduced spatial resolution, which may be most relevant in the slice direction (z) if the volumetric data are obtained as multiple two-dimensional slices. The tracking method was evaluated on computer-generated data sets that simulated various motion patterns. The method was also tested with two sets of in vitro data obtained using a phantom, one acquired as multiple two-dimensional slices and the other using a three-dimensional sequence capable of higher spatial resolution in the z direction. These studies demonstrated that the algorithm can achieve high sub-voxel tracking accuracy.

Algorithms↗