An attenuated projector-backprojector for iterative SPECT reconstruction.

A new ray-driven projector-backprojector which can easily be adapted for hardware implementation is described and simulated in software. The projector-backprojector discretely models the attenuated Radon transform of a source distributed within an attenuating medium as line integrals of discrete pixels, obtained using the standard sampling technique of averaging the emission source or attenuation distribution over small square regions. Attenuation factors are calculated for each pixel during the projection and backprojection operations instead of using precalculated values. The calculation of the factors requires a specification of the attenuation distribution, estimated either from an assumed constant distribution and an approximate body outline or from transmission measurements. The distribution of attenuation coefficients is stored in memory for efficient access during the projection and backprojection operations. The reconstruction of the source distribution is obtained by using a conjugate gradient or SIRT type iterative algorithm which requires one projection and one backprojection operation for each iteration.

Heart↗

The application of matched filtering to x-ray exposure reduction in digital subtraction angiography: clinical results.

This new digital fluorography processing method of matched filtering generates a set of images that have been acquired at continuous video-frame rates (30 per second) over the temporal extent of the bolus (10 seconds), and it combines them to produce the equivalent of a single digital subtraction angiography (DSA) image. Because of the extensive temporal averaging used, the method can provide substantial x-ray exposure reduction per run as compared with conventional techniques for an equivalent signal-to-noise ratio in the final image. The matched filtering technique was compared with conventional pulsed (one per second) DSA images of both extracranial and intracranial arteries, and the results are presented. Matched filtered images provided image quality that was equivalent to that of conventional DSA images at about one-fourth the patient exposure per run for both carotid artery and cerebral vessel studies. Despite long integration times, patient motion irretrievably corrupted image quality in only two of five carotid artery studies and in none of three intracranial studies. Compensation for patient motion is demonstrated, and additional applications and limitations of the technique are discussed.

Angiography↗

Spectral characterization and attenuation measurements in ultrasound.

Various means of characterizing ultrasonic attenuation in tissue are reviewed. A simple method for estimating frequency-dependent attenuation via measurement of the zero crossing density of the signal is presented and validated. Both the effects of the frequency dependence of scatter and stochastic variability of the measurement are considered and discussed. Results of measurements made in phantoms, animals and humans are presented and compared to the theoretical model. The technique is shown to be technically feasible.

Animals↗

Spectral variations in tissues and phantoms.

This paper is concerned with the characterization of attenuation in tissue. A simple method for measuring frequency dependent attenuation is demonstrated. The effects of frequency dependent scatter on the measurement of attenuation are also considered in order to determine the theoretical and practical ramifications of this interfering effect. Finally, a means of placing definitive error bounds on the statistical reliability of the measurement is discussed.

Animals↗

Intravenous arteriography using digital subtraction techniques.

The application of digital computers to electronic x-ray imaging devices has rejuvenated interest in the field of intravenous arteriography. By utilizing computer image subtraction techniques, digital roentgenographic systems based on fluoroscopy or computed tomography (scanned projection radiography) provide significantly improved vascular imaging compared with conventional film subtraction methods. Digital subtraction angiography schemes isolate contrast media in the vessel by detecting differences in images obtained before and after the injection of contrast medium or changes in the relative attenuation of contrast media at different x-ray energies. Present applications include carotid and peripheral arteriography, thoracic and abdominal aortography, pulmonary arteriography, and ventriculography. Future applications may include intracerebral and coronary arteriography. These systems should provide low-risk outpatient screening arteriography.

Angiography↗

Intravenous arteriography using scanned projection radiography.

Visualization of arteries using intravenous injections of contrast material requires an imaging system capable of (a) excellent sensitivity to dilute concentrations of contrast media and (b) adequate temporal resolution to minimize the effects of motion during the exposure. A line-scanned radiography system based on a CT fan-beam detector (high-pressure xenon ionization chamber) was used for phantom and animal studies of intravenous arteriography to demonstrate the potential advantages of this method. Even though line-scanned systems require long scan times compared to existing radiographic methods, they are capable of showing rapidly moving arteries without blurring. Concentrations of 3 mg/ml of iodine could be seen in vessels 2 mm in diameter. Phantom studies using kVp switching showed that bone or soft tissue could be selectively cancelled.

Angiography↗

Utilization of cross-plane rays for three-dimensional reconstruction by filtered back-projection.

Present popular computed tomography (CT) algorithms reconstruct an object from the ray measurements lying on a set of parallel planes. This paper presents an algorithm that can also utilize "cross-plane" rays (i.e., rays that cross through many planes) to reconstruct the object. In this reconstruction algorithm, the ray measurements are grouped into two-dimensional projections, filtered, and stored. The filtered projections can then be back-projected onto a three-dimensional matrix or any plane through the three-dimensional volume. General theoretical aspects are presented and then applied to the special case in which ray measurements have been made in all directions. The algorithm is tested using computer-generated data. Expressions for the noise power spectrum and the variance in the reconstruction are derived. It is shown that the noise-to-signal ratio per detected photon for this reconstruction method is close to a theoretical limit, as it also is for normal CT. The ability to use ray measurements that cross many planes is especially useful in emission CT, where order-of-magnitude improvements in image quality per unit dose can be achieved.

Computers↗

The noise power spectrum in computed X-ray tomography.

An expression is derived showing that the two-dimensional noise power spectrum of computed X-ray tomography is proportional to [G(k)]2/k where k is the radial spatial frequency and G(k) is the one-dimensional corrective filter used in the filtered back-projection reconstuction technique. It is shown that predicted noise power spectra compare well with those estimated from CT reconstructions of simulated noise for both the ramp filter and the Hanning-weighted ramp filter. A consequence of the non-uniform shape of the noise power spectrum is that statistical noise in CT reconstructions is correlated from point to point. Because of this correlation when the reconstructed CT values are averaged over some region, the uncertainty of the average depends on the shape of the region as well as its area. This dependence is confirmed by computer simulations.

Filtration↗

Noise due to photon counting statistics in computed X-ray tomography.

A general expression is derived for the noise due to photon counting statistics in computed X-ray tomography. The variance is inversely proportional to the cube of the resolution distance. For scanners using a water box, the noise in the reconstructed image depends inversely on the number of detected primary photons, summed over all angles, that have passed through a resolution element. Predictions of this formula agree well with the results of computer simulations. It is shown how this formula can be used to determine such parameters as required X-ray flux, detector counting rate, and dose, with special emphasis on tradeoffs between these parameters and resolution. It is also shown that to determine the X-ray attenuation coefficient of a resolution element to a given precision, the number of photons required by computed X-ray tomography is close to a theoretical limit.

Elementary Particles↗

Simultaneous acquisition of phase-contrast angiograms and stationary-tissue images with Hadamard encoding of flow-induced phase shifts.

A technique for the simultaneous acquisition of three-dimensional phase-contrast angiograms and stationary-tissue images is described. Hadamard multiplexed encoding of flow information permits image acquisition times that are a third shorter than those of previous phase-contrast methods. The encoding scheme described also enables differentiation of flow-induced phase shifts from phase shifts due to resonance offset conditions such as field inhomogeneities and chemical shift. Display strategies that combine this phase information with the flow image are described.

Blood Vessels↗

Encoding strategies for three-direction phase-contrast MR imaging of flow.

Three encoding strategies for the measurement of flow velocities in arbitrary directions with phase-contrast magnetic resonance imaging are presented; their noise and dynamic range performance are compared by means of theoretical analysis and computer simulation. A six-point measurement strategy is shown to be quite inefficient in terms of velocity variance per unit time. A simple four-point method exhibits equal dynamic range; its noise depends on flow direction but on average is equal to that of the six-point method. An alternate, balanced four-point method has noise that is direction independent and has, depending on implementation, possibly lower noise levels. Either four-point method is more efficient and is preferred over the six-point approach.

Blood Flow Velocity↗

Minimizing TE in moment-nulled or flow-encoded two- and three-dimensional gradient-echo imaging.

A method for minimizing field-echo delay in moment-nulled gradient-echo imaging is presented. Even though ramps are accounted for, the analysis yields simple closed-form solutions. The method is then generalized to the section-select waveform for three-dimensional volume imaging and to flow encoding for phase-contrast imaging. Three strategies for first-moment selection in phase-contrast imaging are discussed, including a new strategy that always yields the minimum echo delay. Trapezoidal and triangular gradient lobe shapes are analyzed.

Algorithms↗

MR characterization of blood flow in native and grafted internal mammary arteries.

In the postoperative patient with anginal symptoms, differentiation between bypass graft compromise and nonischemic causes has until now been accomplished only by means of x-ray angiography. A non-invasive test is clearly desirable. The authors used a cine phase-contrast (PC) magnetic resonance (MR) imaging technique to characterize blood flow in native and grafted internal mammary arteries (IMAs). Ten volunteers and 15 patients who had recently undergone IMA coronary artery bypass grafting were imaged. Cine PC MR imaging was performed in the transaxial plane at the level of the pulmonary artery bifurcation. Flow in both IMAs was quantified and expressed as a percentage of cardiac output measured in the ascending aorta. In the 15 patients, flow analysis was performed in both the native and grafted IMAs. In the volunteers, IMA blood flow ranged from 2.1% to 4.3% of cardiac output on the left (mean, 3.5%) and 2.1% to 5.1% (mean, 3.5%) on the right. There was considerable intersubject variability, with coefficients of variation of 10.7% for the left and 12.3% for the right IMA. Intrasubject variability was limited, with estimated common standard deviations of 0.45% of cardiac output (range, 0.2%-1.1%) for the left and 0.39% (range, 0.1%-0.6%) for the right IMA. Flow in grafted IMAs was identified in 13 of 15 patients. In one of two patients without demonstrable IMA graft flow, cardiac catheterization confirmed lack of flow. IMA graft flow varied from 28 to 164 mL/min (mean, 80.3 mL/min). This study shows the feasibility of using cine PC MR imaging as a quantitative method of evaluating blood flow in IMA coronary artery bypass grafts.

Adult↗

Noise reduction in three-dimensional phase-contrast MR velocity measurements.

The authors have developed a method to reduce noise in three-dimensional (3D) phase-contrast magnetic resonance (MR) velocity measurements by exploiting the property that blood is incompressible and, therefore, the velocity field describing its flow must be divergence-free. The divergence-free condition is incorporated by a projection operation in Hilbert space. The velocity field obtained with 3D phase-contrast MR imaging is projected onto the space of divergence-free velocity fields. The reduction of noise is achieved because the projection operation eliminates the noise component that is not divergence-free. Signal-to-noise ratio (S/N) gains on the order of 15%-25% were observed. The immediate effect of this noise reduction manifests itself in higher-quality phase-contrast MR angiograms. Alternatively, the S/N gain can be traded for a reduction in imaging time and/or improved spatial resolution.

Algorithms↗

Comparison of cerebral artery blood flow measurements with gated cine and ungated phase-contrast techniques.

Cine phase-contrast (PC) magnetic resonance (MR) pulse sequences have been used to measure blood flow in a variety of vessels. Because the cine PC sequence is time-consuming, this prospective study was undertaken to compare it with an ungated PC technique for measuring average blood flow in individual cerebral arteries to potentially achieve substantial time savings. The following cerebral arteries were studied in 10 healthy volunteers: carotid, basilar, middle cerebral, anterior cerebral, and posterior cerebral. Imaging planes were placed perpendicular to the vessel of interest, and velocity encoding, ranging from 40 to 250 cm/sec, was matched to individual arteries. Good correlation between cine and ungated PC blood flow measurements was obtained for both high- and low-flow vessels, with an overall correlation coefficient of .978. The ungated PC sequence, because of its short imaging time, allows measurement of the blood volume flow rate in the circle of Willis in approximately 20 minutes, a clinically acceptable time.

Adult↗

Velocity and flow quantitation in the superior sagittal sinus with ungated and cine (gated) phase-contrast MR imaging.

Normal blood flow and velocity in the superior sagittal sinus were measured in 30 patients. A fast two-dimensional ungated phase-contrast (PC) pulse sequence was compared with a peripherally gated cine PC technique for velocity and flow quantitation. The same imaging parameters were used for both methods. Measured values for mean velocity and flow obtained with the two methods were compared by using regression analysis and t testing. For blood flow, the correlation coefficient was .976. For velocity measurements, r was .950. Mean flow was 285 mL/min +/- 19 with the ungated PC method and 281 mL/min +/- 19 with the cine PC method. The mean velocities measured with the two methods were 12.94 cm/sec +/- 1.1 and 13.59 cm/sec +/- 1.1, respectively. There was no significant difference (paired t test) between the methods for mean flow or velocity data. This was true even though flow in the superior sagittal sinus is moderately pulsatile, as shown with the cine PC technique. The ungated PC method provided these data in 13 seconds versus 3.5 minutes for the cine PC method.

Blood Flow Velocity↗

Measurement of skeletal muscle motion in vivo with phase-contrast MR imaging.

The ability to measure skeletal muscle motion with phase-contrast magnetic resonance (MR) imaging was tested with a motion phantom that simulated muscle activity. Quantitative analytic data on unidimensional, bidirectional skeletal muscle motion measured in vivo was obtained in four healthy volunteers. MR images of the subjects' forearms were obtained during flexion and extension of the fingers and of the anterior and posterior muscle compartments of the lower leg with various resistances to ankle dorsiflexion and plantar flexion. It was necessary to correct the data for the effects of eddy currents. In vitro evaluation of the technique was done by studying through-plane sinusoidal motion of solid objects. The largest error was underestimation of the peak excursion of 11.5 mm by 0.09 mm (the root mean square error for the cycle was 0.04 mm) In vivo experiments demonstrated the contraction of muscles in relation to each other. Data acquisition and analysis techniques must be refined, but measuring skeletal muscle motion with phase-contrast MR imaging should enhance the understanding of bioengineering fundamentals and muscular changes in disease and adaptation.

Ankle↗