A fiberoptic reflection densitometer with cardiac output calculator.

A catheter-tip densitometer for indocyanine green is described consisting of a cardiac catheter containing optical fibers, an incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the back-scattered (reflected) light to the detection unit. In the detection unit the light is measured by two silicium barrier layer photocells after it has been split into two beams by a beam splitter. In the measuring channel the light passes an 800 nm filter before reaching the photocell. When fiberoptic catheters with glass fibers are employed, the other channel, used for compensation of non-specific effects such as blood flow variations, contains no filter, thus measuring light in a broad spectral band. It is shown that in this way compensation of flow effects may be about two times better than when a 920 nm filter is used. When using plastic optical fibers a 950 nm filter must be used, because above lambda = 850 nm plastic fibers transmit only a band around that wavelength (950 nm). At zero dye concentration the densitometer output or ratio of compensating and measuring photocell output R/R800 is almost insensitive to changes in haemoglobin concentration. When the blood contains dye, however, the influence of haemoglobin concentration is considerable. The densitometer output R/R800 is linearly related to dye concentration up to 50 mg . 1-1, the output R920/R800 up to 30 mg . 1(-1). The output R/R800 decreases with decreasing oxygen saturation; the slope of the calibration line, however, appears to be unaffected. The processing unit also contains an analog cardiac output calculator consisting of an integrator and a divider. Central dye dilution curves recorded from the pulmonary artery after injection of dye into the right atrium or a caval vein come down to the baseline. At this moment the reading of a digital voltmeter displaying the divider output calibrated in 1 . min-1 can be held and the reading taken.

Animals

A fiberoptic reflection oximeter.

A catheter tip oximeter is described consisting of a cardiac catheter containing optical fibers, and incandescent light source, a light detection unit and a processing unit. Half of the optical fibers guide the light to the blood at the tip of the catheter, the other half the backscattered (reflected) light to the detection unit. The detection unit contains a dichroic mirror, transmitting most of the light with lambda less than 800 nm and reflecting most of the light with lambda greater than 900 nm, thus splitting the light into two beams. These pass through interference filters with nominal wavelengths of 640 and 920 nm respectively, and are focused on silicium barrier layer photocells. The photocell signals are amplified and fed into a divider giving the ratio of measuring (R640) and compensating (R920) photocell output. The relationship between log R640/R920 and oxygen saturation is represented by a slightly curved line. The relation may be linearized by subtracting a constant voltage from the divided output before taking the logarithm. The slope of the calibration line is dependent on the total haemoglobin concentration. Nonetheless an average calibration line can be used between 70 and 100% oxygen saturation. For 78 measurements of pig blood samples in this range (haemoglobin concentration between 96 and 161 g.1(-1)), the standard deviation of the difference between the fiberoptic oximeter and a Radiometer OSM1 oxygen saturation meter was 1.9% saturation, for 152 samples over the entire saturation range the standard deviation of the difference was 3.1% saturation. The influence of the flow velocity of blood on the light reflection depends on wavelength as well as on oxygen saturation. Therefore, complete compensation for the flow effect is not possible by simple means.

Animals