PubMed Health⌕ Search

Biomedical subjects

N Komiya

Publications and source records attributed to N Komiya.

9 recordsLinked to original sources

Double ventricular response via dual atrioventricular nodal pathways resulting with nonreentrant supraventricular tachycardia and successfully treated with radiofrequency catheter ablation.

We report a patient with a complex nonreentrant supraventricular tachycardia because of double ventricular response resulting from antegrade dual atrioventricular (AV) nodal pathways. We could induce double ventricular response and confirm dual AV nodal pathways by AV simultaneous pacing during basic stimulation proceeding with programmed atrial single extrastimulation. As far as we know, it is the first report about the application of the AV simultaneous basic stimulation to prove the sustained nonreentrant tachycardia because of simultaneous conduction over dual AV nodal pathways. This was also confirmed by absence of the arrhythmia immediately after the elimination of the slow pathway conduction by radiofrequency ablation.

Adult↗

The right ventricular outflow tract as an unusual location for an implantable defibrillator electrode in a patient with arrhythmogenic right ventricular dysplasia.

A 41-year-old woman with arrhythmogenic right ventricular dysplasia (ARVD) underwent the implantation of an implantable cardioverter-defibrillator (ICD), in which the defibrillator electrode was unusually located in the right ventricular (RV) outflow tract. Although fractionated electrograms were demonstrated in the RV apex, which is the usual site for ICD electrodes, normal electrograms were recorded in the RV outflow tract during an electrophysiologic study. An electrode with a screw-in tip was used to fix the implant in the RV outflow tract and obtain successful defibrillation. If normal electrograms are recorded in the RV outflow tract, the site may prove to be an alternative location for an ICD electrode even for ARVD patients.

Adult↗

Ruthenium-catalyzed oxidation of alkanes with tert-butyl hydroperoxide and peracetic acid

The ruthenium-catalyzed oxidation of alkanes with tert-butyl hydroperoxide and peracetic acid gives the corresponding ketones and alcohols highly efficiently at room temperature. The former catalytic system, RuCl(2)(PPh(3))(3)-t-BuOOH, is preferable to the oxidation of alkylated arenes to give aryl ketones. The latter system, Ru/C-CH(3)CO(3)H, is suitable especially for the synthesis of ketones and alcohols from alkanes. The ruthenium-catalyzed oxidation of cyclohexane with CH(3)CO(3)H in trifluoroacetic acid/CH(2)Cl(2) at room temperature gave cyclohexyl trifluoroacetate and cyclohexanone with 90% conversion and 90% selectivity (85:15). The mechanistic study indicates that these catalytic oxidations of hydrocarbons involve oxo-ruthenium species as key intermediates.

Journal Article↗

Preserving normal ventricular activation versus atrioventricular delay optimization during pacing: the role of intrinsic atrioventricular conduction and pacing rate.

The purpose of the study was to compare the effects of DDD pacing with optimal AV delay and AAI pacing on the systolic and diastolic performance at rest in patients with prolonged intrinsic AV conduction (first-degree AV block). We studied 17 patients (8 men, aged 69 +/- 9 years) with dual chamber pacemakers implanted for sick sinus syndrome in 15 patients and paroxysmal high degree AV block in 2 patients. Aortic flow and mitral flow were evaluated using Doppler echocardiography. Study protocol included the determination of the optimal AV delay in the DDD mode and comparison between AAI and DDD with optimal AV delay for pacing rate 70/min and 90/min. Stimulus-R interval during AAI (ARI) was 282 +/- 68 ms for rate 70/min and 330 +/- 98 ms for rate 90/min (P < 0.01). The optimal AV delay was 159 +/- 22 ms. AV delay optimization resulted in an increase of an aortic flow time velocity integral (AFTVI) of 16% +/- 9%. At rate 70/min the patients with ARI < or = 270 ms had higher AFTVI in AAI than in DDD (0.214 +/- 0.05 m vs 0.196 +/- 0.05 m, P < 0.01), while the patients with ARI > 270 ms demonstrated greater AFTVI under DDD compared to AAI (0.192 +/- 0.03 m vs 0.166 +/- 0.02 m, P < 0.01). At rate 90/min AFTVI was higher during DDD than AAI (0.183 +/- 0.03 m vs 0.162 +/- 0.03 m, P < 0.01). Mitral flow time velocity integral (MFTVI) at rate 70/min was higher in DDD than in AAI (0.189 +/- 0.05 m vs 0.173 +/- 0.05 m, P < 0.01), while at rate 90/min the difference was not significant in favor of DDD (0.149 +/- 0.05 m vs 0.158 +/- 0.04 m). The results suggest that in patients with first-degree AV block the relative impact of DDD and AAI pacing modes on the systolic performance depends on the intrinsic AV conduction time and on pacing rate.

Aged↗

Radiofrequency catheter ablation of a concealed atrioventricular accessory pathway associated with a coronary sinus diverticulum.

A 31-year-old woman underwent radiofrequency catheter ablation of a concealed left posteroseptal accessory pathway associated with a coronary sinus diverticulum. The patient had previously undergone unsuccessful catheter ablation of the posteroseptal region of the mitral annulus. Coronary sinus venography revealed the presence of the diverticulum near the ostium. An electrogram in the neck of the diverticulum showed the shortest ventriculoatrial conduction time and a large accessory pathway potential during atrioventricular reciprocating tachycardia. The pathway was successfully ablated within the neck of the diverticulum. The findings in this case underscore the importance of coronary sinus venography before ablation.

Adult↗

Electrophysiological properties of the left atrium evaluated by coronary sinus pacing in patients with atrial fibrillation.

Repetitive atrial firing (RAF), marked fragmentation of atrial activity (FAA), and interatrial conduction delay (CD) have been shown to be electrophysiological features of the atrium in patients with atrial fibrillation (AF). Moreover, it has been observed that atrial extrastimuli are more likely to induce AF when delivered from the right atrial appendage (RAA) than from the distal coronary sinus (CSd). We examined the electrophysiological properties of the atrial muscle by CS and RAA stimulation in patients with paroxysmal AF. Patients were divided into two groups: group I, consisting of 18 patients with clinical paroxysmal AF; and group II, consisting of 22 patients with various cardiac arrhythmias in which the substrate does not exist in the atrium. In group I, the following values of electrophysiological parameters of the atrium indicated that AF was more likely to be induced during RAA pacing than CSd pacing: atrial effective refractory period (RAA vs CSd: 201 +/- 28 ms vs 240 +/- 35 ms, P < 0.001), RAF zone (16 +/- 25 ms vs 0 +/- 0 ms, P < 0.03), FAA zone (38 +/- 37 ms vs 5 +/- 19 ms, P < 0.01), maximum interatrial conduction time (144 +/- 19 ms vs 93 +/- 19 ms, P < 0.0001) and CD zone (53 +/- 21 ms vs 9 +/- 18 ms, P < 0.0001). The values of the electrophysiological parameters of the atrium evaluated by CSd pacing in group I patients were not significantly different from those in group II patients. In conclusion, when coronary sinus stimulation is performed, electrophysiological properties of the atrium in patients with AF show a significant decrease in atrial vulnerability compared to stimulation from RAA and also show similar values to those in patients without AF. It might be suggested that the left posterior or posterolateral atrium is electrophysiologically stable even in patients with paroxysmal AF.

Adult↗