Identification of an isomer impurity in piperaquine drug substance.

A significant contaminant of the antimalarial drug piperaquine (1,3-bis-[4-(7-chloroquinolyl-4)-piperazinyl-1]propane) has been identified using liquid chromatography-mass spectrometry (LC-MS) and 2D NMR spectroscopy (1H-1H COSY, 1H-13C HSQC, 1H-13C HMBC). The impurity was identified as the positional isomer 1-[(5-chloroquinolin-4)-piperazinyl]-3-[(7-chloroquinolin-4)-piperazinyl]propane. The impurity is formed because of contamination of batches of 4,7-dichloroquinoline (a precursor in the synthesis of piperaquine) with 4,5-dichloroquinoline. The amount of impurity (peak area impurity/peak area piperaquine using LC-UV at 347 nm) in old batches of piperaquine and in Artekin (the combination of dihydroartemisinin-piperaquine) ranged from 1.5 to 5%.

Antimalarials↗

Characterization of human urinary metabolites of the antimalarial piperaquine.

Five metabolites of the antimalarial piperaquine (PQ) (1,3-bis-[4-(7-chloroquinolyl-4)-piperazinyl-1]-propane) have been identified and their molecular structures characterized. After a p.o. dose of dihydroartemisinin-piperaquine, urine collected over 16 h from two healthy subjects was analyzed using liquid chromatography (LC)/UV, LC/tandem mass spectrometry (MS/MS), Fourier transform ion cyclotron resonance (FTICR)/MS, and H NMR. Five different peaks were recognized as possible metabolites [M1, 320 m/z; M2, M3, and M4, 551 m/z (PQ + 16 m/z); and M5, 567 m/z (PQ + 32 m/z)] using LC/MS/MS with gradient elution. The proposed carboxylic M1 has a theoretical monoisotopic molecular mass of 320.1166 m/z, which is in accordance with the FTICR/MS (320.1168 m/z) findings. The LC/MS/MS results also showed a 551 m/z metabolite (M2) with a distinct difference both in polarity and fragmentation pattern compared with PQ, 7-hydroxypiperaquine, and the other 551 m/z metabolites. We suggest that this is caused by N-oxidation of PQ. The results showed two metabolites (M3 and M4) with a molecular ion at 551 m/z and similar fragmentation pattern as both PQ and 7-hydroxypiperaquine; therefore, they are likely to be hydroxylated PQ metabolites. The molecular structures of M1 and M2 were also confirmed using H NMR. Urinary excretion rate in one subject suggested a terminal elimination half-life of about 53 days for M1. Assuming formation rate-limiting kinetics, this would support recent findings that the terminal elimination half-life of PQ has been underestimated previously.

Antimalarials↗

A simple and rapid liquid chromatographic assay for evaluation of potentially counterfeit Tamiflu.

A simple and rapid liquid chromatographic assay for the evaluation of potentially counterfeit oseltamivir (Tamiflu has been developed and assessed. The assay uses approximately 1mg Tamiflu powder when used for authentication and content estimate. The procedure was validated using 50 replicates analysed during five independent series with a total R.S.D. of 11.2%. The assay can also be used to monitor the exact content of oseltamivir in Tamiflu capsules. One Tamiflu capsule was transferred to a 250mL volumetric flask and 150mL water was added. The flask was placed in an ultrasonic bath at 40 degrees C for 20min to dissolve the capsule. The solution was allowed to cool to room temperature before the flask was filled up to the mark (250mL). A small aliquot was centrifuged and then directly injected into the LC-system for quantification. Oseltamivir was analysed by liquid chromatography with UV detection on a Hypersil Gold column (150mmx4.6mm) using a mobile phase containing methanol-phosphate buffer (pH 2.5; 0.1M) (50:50, v/v) at a flow rate of 1.0mL/min. The assay was implemented for the analysis of Tamiflu purchased over the Internet and at local pharmacies in Thailand and Vietnam.

Acetamides↗

An open, randomized comparison of artesunate plus mefloquine vs. dihydroartemisinin-piperaquine for the treatment of uncomplicated Plasmodium falciparum malaria in the Lao People's Democratic Republic (Laos).

OBJECTIVE: To determine the efficacy and safety of oral dihydroartemisinin-piperaquine (DP, Artekin) in the treatment of uncomplicated Plasmodium falciparum malaria in southern Laos. METHODS: An open, randomized clinical trial of oral artesunate-mefloquine (AM) vs. DP in 220 patients with acute uncomplicated falciparum malaria in Savannakhet Province, Laos. RESULTS: The 42-day cure rates (95% CI), as determined by survival analysis and adjusted for reinfection, were excellent and similar for the two groups [99 (94-100)% and 100 (100-100)% for AM and DP, respectively]. The median (range) fever and parasite clearance times for the AM and DP groups were also similar [20 (4-63) h and 2 (1-4) days vs. 20 (7-57) and 2 (1-4) days, logrank P = 0.4 and 0.17, respectively]. There were more patients with at least one potential side effect following treatment in the AM group when compared with the DP group [64/110 (58%) vs. 48/110 (44%), respectively, P = 0.031]. CONCLUSION: Dihydroartemisinin-piperaquine did not have superior efficacy to AM for the treatment of uncomplicated falciparum malaria in Laos but was associated with fewer adverse effects.

Administration, Oral↗

A new approach to evaluate stability of amodiaquine and its metabolite in blood and plasma.

A stability study for amodiaquine (AQ) and desethylamodiaquine (AQm) in whole blood and plasma is reported. AQ, AQm and chloroquine (CQ) were simultaneously analysed and the ratios AQ/CQ and AQm/CQ were used to ensure correct interpretation of the stability results. CQ was stable in whole blood and plasma at all tested temperatures enabling it to be a stability marker in stability studies. Simultaneous analysis of compounds, of which at least one is already known to be stable, permits a within sample ratio to be used as a stability indicator. The new approach significantly reduced bias when compared to the traditional approach. AQ and AQm were stable in plasma at -86 degrees C and -20 degrees C for 35 days, at 4 degrees C for 14 days and at 22 degrees C for 1 day. AQ and AQm were stable in blood at -86 degrees C and 4 degrees C for 35 days, at -20 degrees C and 22 degrees C for 7 days and at 37 degrees C for 1 day.

Amodiaquine↗

High throughput assay for the determination of piperaquine in plasma.

A high throughput assay for the determination of the antimalarial piperaquine in plasma has been developed and validated. The assay utilises 96-wellplate formats throughout the whole procedure, and easily enables a throughput of 192 samples a day using a single LC system. Buffer (pH 2.0; 0.05 M) containing internal standard was added to 0.25 mL plasma in a 96-wellplate (2 mL wells). The samples were extracted on a MPC solid phase extraction deep well 96-wellplate (3M Empore). Piperaquine and internal standard were analysed by liquid chromatography with UV detection on a Chromolith Performance (100 mm x 4.6 mm) column with a mobile phase containing acetonitrile-phosphate buffer (pH 2.5; 0.1 M) (8:92, v/v) at a flow rate of 3.0 mL/min. The within-day precisions for piperaquine were 3.3 and 2.3% at 40 and 1250 ng/mL, respectively. The between-day precisions for piperaquine were 5.8 and 1.3% at 40 and 1250 ng/mL, respectively. The total assay precisions using 29 replicates over 5 days were 6.7, 4.5 and 2.7% at 40, 200 and 1250 ng/mL, respectively. The lower limit of quantification (LLOQ) and the limit of detection (LOD) were 10 and 5 ng/mL, respectively using 0.25 mL plasma. Using 1 mL of plasma, it was possible to decrease LLOQ and LOD to 2.5 and 1.25 ng/mL, respectively.

Animals↗

High throughput assay for the determination of lumefantrine in plasma.

A high throughput bioanalytical assay for the determination of lumefantrine in plasma has been developed and validated extensively. The within-day precisions for lumefantrine were 5.2, 3.5 and 2.5% at 200, 2000 and 15000 ng/mL, respectively. The between-day precisions were 4.0, 2.8 and 3.1% at 200, 2000 and 15000 ng/mL, respectively. The lower limits of quantification (LLOQ) and the limits of detection (LOD) were 25 and 10 ng/mL, respectively using 0.250 mL plasma. The average recovery of lumefantrine was 85% and independent upon concentration. The use of 96-well plate format and short chromatographic run has increased the daily sample throughput four times. The assay is particularly suitable for large therapeutic drug monitoring studies using day 7 sampling.

Antimalarials↗

Development and validation of a bioanalytical method using automated solid-phase extraction and LC-UV for the simultaneous determination of lumefantrine and its desbutyl metabolite in plasma.

A bioanalytical method for the determination of lumefantrine (LF) and its metabolite desbutyl-lumefantrine (DLF) in plasma by solid-phase extraction (SPE) and liquid chromatography has been developed. Plasma proteins were precipitated with acetonitrile:acetic acid (99:1, v/v) containing a DLF analogue internal standard before being loaded onto a octylsilica (3 M Empore) SPE column. Two different DLF analogues were evaluated as internal standards. The compounds were analysed by liquid chromatography UV detection on a SB-CN (250 mm x 4.6 mm) column with a mobile phase containing acetonitrile-sodium phosphate buffer pH (2.0; 0.1 M) (55:45, v/v) and sodium perchlorate 0.05 M. Different SPE columns were evaluated during method development to optimise reproducibility and recovery for LF, DLF and the two different DLF analogues. The within-day precisions for LF were 6.6 and 2.1% at 0.042 and 8.02 microg/mL, respectively, and for DLF 4.5 and 1.5% at 0.039 and 0.777 microg/mL, respectively. The between-day precisions for LF were 12.0 and 2.9% at 0.042 and 8.02 microg/mL, respectively, while for DLF 0.7 and 1.2% at 0.039 and 0.777 microg/mL, respectively. The limit of quantification was 0.024 and 0.021 microg/mL for LF and DLF, respectively. Different amounts of lipids in plasma did not affect the absolute recovery of LF or DLF.

Chromatography, Liquid↗

Development and validation of a solid-phase extraction-liquid chromatographic method for determination of amoxicillin in plasma.

A bioanalytic method for the determination of amoxicillin in plasma by hydrophilic interaction solid-phase extraction and liquid chromatography has been developed and validated. Plasma was precipitated with acetonitrile before samples were loaded onto a zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) solid-phase extraction column. Amoxicillin was analyzed by liquid chromatography on an Aquasil (150 x 4.6 mm) LC column with mobile-phase acetonitrile: phosphate buffer (pH 2.5; 0.1 mol/L) (7:93, v/v) and UV detection at 230 nm. A regression model using 1/concentration weighting was found the most appropriate for quantification. The intraassay precision for plasma was 3.3% at 15.0 microg/mL and 10.9% at 0.200 microg/mL. The interassay precision for plasma was 1.8% at 15.0 microg/mL and 7.5% at 0.200 microg/mL. The total-assay precision for plasma over 4 days using a total of 20 replicates was 13.2%, 5.5%, and 3.8% at 0.200 microg/mL, 3.00 microg/mL, and 15.0 microg/mL, respectively. The lower limit of quantification and the limit of detection were 0.050 microg/mL and 0.025 microg/mL, respectively, for 100 microL plasma. Long-term storage stability studies of amoxicillin in plasma indicate that a temperature of -80 degrees C is necessary to prevent degradation of amoxicillin.

Amoxicillin↗

Automated solid-phase extraction method for the determination of piperaquine in capillary blood applied onto sampling paper by liquid chromatography.

A bioanalytical method for the determination of piperaquine in 100 microL blood applied onto sampling paper, by solid-phase extraction and liquid chromatography, has been developed and validated. Blood spots were cut into small pieces prior to addition of 0.3M perchloric acid, acetonitrile and phosphate buffer containing an internal standard. The liquid phase was loaded onto a mixed phase cation-exchange (MPC) solid-phase extraction column. Piperaquine and the internal standard were analysed by liquid chromatography and separated on a Chromolith Performance (100 mm x 4.6 mm) column with acetonitrile:phosphate buffer pH 2.5, I = 0.1 (8:92, v/v) at the flow of 3.5 mL/min. The UV detection was performed at 345 nm. The intra-assay precision was 12.0% at 0.150 microM, 7.3% at 1.25 microM and 7.3% at 2.25 microM. The inter-assay precision was 1.8% at 0.150 microM, 5.2% at 1.25 microM and 2.8% at 2.25 microM. The lower limit of quantification (LLOQ) was determined to 0.050 microM where the precision was 14.7%.

Antimalarials↗

Automated solid-phase extraction method for the determination of piperaquine in plasma by peak compression liquid chromatography.

A validated bioanalytical method for the determination of piperaquine (PQ) in plasma by solid-phase extraction (SPE) and liquid chromatography (LC) using peak compression is presented. Protein is precipitated from plasma with acetonitrile-1% aqueous acetic acid (85:15, v/v). An internal standard (IS) is added to the samples before they are loaded onto a strong cation exchanger (Isolute PRS) SPE column. PQ and the IS are analyzed by LC on a Zorbax SB-CN column (250 x 4.0 mm) with the mobile phase acetonitrile-phosphate buffer [I = 0.1, pH 2.5 (12:88, v/v)] and UV detection at 345 nm. Trichloroacetic acid (TCA) is added to the samples prior to injection into the chromatography system. PQ elutes in a gradient of TCA, which enables peak compression of PQ and significantly higher peak efficiency as a result. The intraassay precision for plasma is determined to be 5.4% at 3.00 microM and 5.8% at 0.050 microM. The interassay precision for plasma is 1.3% at 3.00 microM and 10.0% at 0.050 microM. The lower limit of quantitation and the limit of detection are 0.025 and 0.005 microM, respectively.

Antimalarials↗

Automated solid-phase extraction method for the determination of piperaquine in whole blood by rapid liquid chromatography.

A bioanalytic method for the determination of piperaquine in whole blood by solid-phase extraction and rapid liquid chromatography has been developed and validated. Whole blood was hemolyzed with deionized water, and an internal standard was added to the samples before they were loaded onto a PRS cation-exchange solid-phase extraction column. Piperaquine and internal standard were analyzed by liquid chromatography on a Chromolith Performance (100 x 4.6 mm) column with mobile phase acetonitrile:phosphate buffer, I = 0.1, pH 2.5 (8:92, vol/vol), flow rate 4 mL x min-1, and UV detection at 345 nm. The intraassay precision for whole blood was 3.2% at 3.00 microM and 12.3% at 0.100 microM. The interassay precision for whole blood was 1.8% at 3.00 microM and 5.2% at 0.100 microM. The lower limit of quantification and the limit of detection were 0.050 microM and 0.010 microM, respectively.

Chromatography, Liquid↗

Automated solid-phase extraction method for the determination of atovaquone in plasma and whole blood by rapid high-performance liquid chromatography.

A bioanalytical method for the determination of atovaquone in plasma and whole blood by solid-phase extraction and high-performance liquid chromatography has been developed and validated. A structurally similar internal standard was added and protein was precipitated from plasma and whole blood with acetonitrile before being loaded on to a C8 solid-phase extraction column. Atovaquone and internal standard were analysed by high-performance liquid chromatography on a C18 J'Sphere ODS-M80 (150x4.0 mm) column with mobile phase acetonitrile-phosphate buffer, 0.01 M, pH 7.0 (65:35, v/v) and UV detection at 277 nm. The intra-assay precisions for plasma and whole blood were 2.2% and 1.9% respectively at 12 microM and 6.0% and 5.6% respectively at 0.75 microM. The inter-assay precisions for plasma and whole blood were 1.4% and 2.1% respectively at 12 microM and 4.9% and 3.4% respectively at 0.75 microM. The lower limit of quantification in plasma and whole blood were 150 nM. The limit of detection in plasma and whole blood were 30 nM.

Antiprotozoal Agents↗

Simultaneous quantitation of the highly lipophilic atovaquone and hydrophilic strong basic proguanil and its metabolites using a new mixed-mode SPE approach and steep-gradient LC.

A bioanalytical method is described for the simultaneous quantitative analysis of the highly lipophilic atovaquone and the strong basic proguanil with metabolites in plasma. The drugs are extracted from protein precipitated plasma samples on a novel mixed-mode solid-phase extraction (SPE) column containing carboxypropyl and octyl silica as functional groups. The analytes are further separated and quantitated using a steep-gradient liquid chromatographic method on a Zorbax SB-CN column with UV detection at 245 nm. Two different internal standards (IS) are used in the method to compensate for both types of analytes. A structurally similar IS to atovaquone is added with acetonitrile to precipitate proteins from plasma. A structurally similar IS to proguanil and its metabolites is added with phosphate buffer before samples are loaded onto the SPE columns. A single elution step is sufficient to elute all analytes. The method is validated according to published guidelines and shows excellent performance. The within-day precisions, expressed as relative standard deviation, are lower than 5% for all analytes at three tested concentrations within the calibration range. The between-day precisions are lower than 13% for all analytes at the same tested concentrations. The limit of quantitation is 25 nM for the basic substances and 50 nM for atovaquone. Several considerations regarding development and optimization of a method for determination of analytes with such a difference in physiochemical properties are discussed.

Adsorption↗