PubMed Health⌕ Search

Biomedical subjects

N Lindegardh

Publications and source records attributed to N Lindegardh.

2 recordsLinked to original sources

A new approach to evaluate regression models during validation of bioanalytical assays.

The quality of bioanalytical data is highly dependent on using an appropriate regression model for calibration curves. Non-weighted linear regression has traditionally been used but is not necessarily the optimal model. Bioanalytical assays generally benefit from using either data transformation and/or weighting since variance normally increases with concentration. A data set with calibrators ranging from 9 to 10000 ng/mL was used to compare a new approach with the traditional approach for selecting an optimal regression model. The new approach used a combination of relative residuals at each calibration level together with precision and accuracy of independent quality control samples over 4 days to select and justify the best regression model. The results showed that log-log transformation without weighting was the simplest model to fit the calibration data and ensure good predictability for this data set.

Algorithms↗

Development and validation of an automated solid phase extraction and liquid chromatographic method for the determination of piperaquine in urine.

A sensitive and specific bioanalytical method for determination of piperaquine in urine by automated solid-phase extraction (SPE) and liquid chromatography (LC) has been developed and validated. Buffered urine samples (containing internal standard) were loaded onto mixed phase (cation-exchange and octylsilica) SPE columns using an ASPEC XL SPE robot. Chromatographic separation was achieved on a Chromolith Performance RP-18e (100 mm x 4.6 mm I.D.) LC column with phosphate buffer (pH 2.5; 0.1 mol/L)-acetonitrile (92:8, v/v). Piperaquine was analysed at a flow rate of 3 mL/min with UV detection at 347 nm. A linear regression model on log-log transformed data was used for quantification. Within-day precision for piperaquine was 1.3% at 5000 ng/mL and 6.6% at 50 ng/mL. Between-day precision for piperaquine was 3.7% at 5000 ng/mL and 7.2% at 50 ng/mL. Total-assay precision for piperaquine over 4 days using five replicates each day (n = 20) was 4.0%, 5.2% and 9.8% at 5000, 500 and 50 ng/mL, respectively. The lower limit of quantification (LLOQ) was set to 3 ng/mL using 1 mL of urine, which could be lowered to 0.33 ng/mL when using 9 mL of urine and an increased injection volume.

Animals↗