Test of the local effect model using clinical data: tumour control probability for lung tumours after treatment with carbon ion beams.

The treatment planning approach used within the heavy ion tumour therapy project at GSI Darmstadt includes a biological optimisation, which is based on a biophysical model, the Local Effect Model (LEM). Here we show that the predictions of the LEM are in good agreement with clinical data obtained at the HIMAC in Chiba for the treatment of non-small-cell lung cancer, and the steep dose response for carbon ions is reproduced correctly. This steeper increase corresponds to an increasing RBE with increasing dose, which apparently is in contradiction to the systematics observed in general for in vitro measurements. A possible explanation of this discrepancy is based on the interindividual variation of photon sensitivity.

Carbon Radioisotopes↗

Chromosomal aberrations induced by high-energy iron ions with shielding.

Biophysical models are commonly used to evaluate the effectiveness of shielding in reducing the biological damage caused by cosmic radiation in space flights. To improve and validate these codes biophysical experiments are needed. We have measured the induction of chromosomal aberrations in human peripheral blood lymphocytes exposed in vitro to 500 MeV/n iron ion beams (dose range 0.1-1 Gy) after traversing shields of different material (lucite, aluminium, or lead) and thickness (0-11.3 g/cm2). For comparison, cells were exposed to 200 MeV/n iron ions and to X-rays. Chromosomes were prematurely condensed by a phosphatase inhibitor (calyculin A) to avoid cell-cycle selection produced by the exposure to high-LET heavy-ion beams. Aberrations were scored in chromosomes 1, 2, and 4 following fluorescence in situ hybridization. The fraction of aberrant lymphocytes has been evaluated as a function of the dose at the sample position, and of the fluence of primary 56Fe ions hitting the shield. The influence of shield thickness on the action cross-section for the induction of exchange-type aberrations has been analyzed, and the dose average-LET measured as a function of the shield thickness. These preliminary results prove that the effectiveness of heavy ions is modified by shielding, and the biological damage is dependent upon shield thickness and material.

Aluminum↗

Characterisation of an ultra-miniature counter for microdosimetric measurements in a therapeutic 400 MeV/A carbon beam.

Single event spectra of a clinical carbon beam have been measured by an ultra-miniature tissue-equivalent proportional counter (UMC). In order to cover the energy range of the Bragg peak, the incident energy of the carbon beam was degraded by aluminium plates. Single event spectra for carbon-events incident to the UMC were analysed and selected at several carbon energies using thin scintillation counters. It was found that the dose weighted lineal energy distributions have a doublet peak structure due to incident carbon beam and fragment contributions.

Calibration↗

[Development of a multi-layer ion chamber for measurement of depth dose distributions of heavy-ion therapeutic beam for individual patients].

In heavy-ion radiotherapy, an accelerated beam is modified to realize a desired dose distribution in patients. The setup of the beam-modifying devices in the irradiation system is changed according to the patient, and it is important to check the depth dose distributions in the patient. In order to measure dose distributions realized by an irradiation system for heavy-ion radiotherapy, a multi-layer ionization chamber(MLIC) was developed. The MLIC consists of 64 ionization chambers, which are stacked mutually. The interval between each ionization chamber is about 4.1 mm water. There are signal and high voltage plates in the MILC, which are used as electrodes of the ionization chambers and phantom. Depth dose distribution from 5.09 mm to 261.92 mm water can be measured in about 30 seconds using this MLIC. Thus, it is possible to check beam quality in a short amount of time.

Heavy Ion Radiotherapy↗

Biophysical characteristics of HIMAC clinical irradiation system for heavy-ion radiation therapy.

PURPOSE: The irradiation system and biophysical characteristics of carbon beams are examined regarding radiation therapy. METHODS AND MATERIALS: An irradiation system was developed for heavy-ion radiotherapy. Wobbler magnets and a scatterer were used for flattening the radiation field. A patient-positioning system using X ray and image intensifiers was also installed in the irradiation system. The depth-dose distributions of the carbon beams were modified to make a spread-out Bragg peak, which was designed based on the biophysical characteristics of monoenergetic beams. A dosimetry system for heavy-ion radiotherapy was established to deliver heavy-ion doses safely to the patients according to the treatment planning. A carbon beam of 80 keV/microm in the spread-out Bragg peak was found to be equivalent in biological responses to the neutron beam that is produced at cyclotron facility in National Institute Radiological Sciences (NIRS) by bombarding 30-MeV deuteron beam on beryllium target. The fractionation schedule of the NIRS neutron therapy was adapted for the first clinical trials using carbon beams. RESULTS: Carbon beams, 290, 350, and 400 MeV/u, were used for a clinical trial from June of 1994. Over 300 patients have already been treated by this irradiation system by the end of 1997.

Calibration↗

Relationship between CT number and electron density, scatter angle and nuclear reaction for hadron-therapy treatment planning.

The precise conversion of CT numbers to their electron densities is essential in treatment planning for hadron therapy. Although some conversion methods have already been proposed, it is hard to check the conversion accuracy during practical therapy. We have estimated the CT numbers of real tissues by a calculational method established by Mustafa and Jackson. The relationship between the CT numbers and the electron densities was investigated for various body tissues as well as some tissue-equivalent materials used for a conversion to check the accuracy of the current conversion methods. The result indicates a slight disagreement at the high-CT-number region. A precise estimation of the multiple scattering, nuclear reaction and range straggling of incident particles has been considered as being important to realize higher-level conformal therapy in the future. The relationship between these parameters and the CT numbers was also investigated for tissues and water. The result shows that it is sufficiently practical to replace these parameters for real tissues with those for water by adjusting the density.

Biophysical Phenomena↗

Carbon beam dosimetry intercomparison at HIMAC.

To verify international uniformity in carbon beam dosimetry, an intercomparison programme was carried out at the heavy ion medical accelerator (HIMAC). Dose measurements with ionization chambers were performed for both unmodulated and 6 cm modulated 290 MeV/nucleon carbon beams. Although two different dosimetry procedures were employed, the evaluated values of absorbed dose were in good agreement. This comparison established a common framework for ionization chamber dosimetry between two different carbon beam therapy facilities.

Carbon↗

Initial recombination in a parallel-plate ionization chamber exposed to heavy ions.

For exact determination of absorbed dose in heavy-ion irradiation fields which are used in radiation therapy and biological experiments, ionization chambers have been characterized with defined heavy-ion beams and correction factors. The LET (linear energy transfer) dependence of columnar recombination in a parallel-plate ionization chamber has been examined. Using 135 MeV/u carbon and neon beams, the ion collection efficiency was measured for several gases (air, carbon dioxide, argon and tissue-equivalent gas). 95 MeV/u argon beams and 90 MeV/u iron beams were also used for measurements of columnar recombination in air. As expected by Jaffe theory, the inverse of the ratio of the ionization charge to the saturated ionization charge had a linear relationship with the inverse of the electric field strength in the region below 0.002 V(-1) cm. The gradient of the line increases as the LET of the heavy ions increases. A strong LET dependence of the gradient was observed in air and carbon dioxide. The LET dependence was not observed in tissue-equivalent gas, nitrogen or argon. The exact depth-dose distribution of the heavy-ion beam was obtained by this correction of the initial recombination effect for the collected ionization charge. The columnar recombination in air was analysed using Jaffe theory; the obtained parameter b (a track radius) should be in the range between 0.001 cm and 0.005 cm, whereas the value obtained by Jaffe is 0.00179 cm. The value of the parameter b should increase as the LET of the heavy-ion beam increases in order to reproduce the experimental values of the initial recombination.

Air↗

Rejoining and misrejoining of radiation-induced chromatin breaks. IV. Charged particles.

We have recently reported the kinetics of chromosome rejoining and exchange formation in human lymphocytes exposed to gamma rays using the techniques of fluorescence in situ hybridization (FISH) and premature chromosome condensation (PCC). In this paper, we have extended previous measurements to cells exposed to charged particles. Our goal was to determine differences in chromatin break rejoining and misrejoining after exposure to low- and high-linear energy transfer (LET) radiation. Cells were irradiated with hydrogen, neon, carbon or iron ions in the LET range 0.3-140 keV/microm and were incubated at 37 degrees C for various times after exposure. Little difference was observed in the yield of early prematurely condensed chromosome breaks for the different ions. The kinetics of break rejoining was exponential for all ions and had similar time constants, but the residual level of unrejoined breaks after prolonged incubation was higher for high-LET radiation. The kinetics of exchange formation was also similar for the different ions, but the yield of chromosome interchanges measured soon after exposure was higher for high-LET particles, suggesting that a higher fraction of DNA breaks are misrejoined quickly. On the other hand, the rate of formation of complete exchanges was slightly lower for densely ionizing radiation. The ratios between the yields of different types of aberrations observed at 10 h postirradiation in prematurely condensed chromosome preparations were dependent on LET. We found significant differences between the yields of aberrations measured in interphase (after repair) and metaphase for densely ionizing radiation. This difference might be caused by prolonged mitotic delay and/or interphase death. Overall, the results point out significant differences between low- and high-LET radiation for the formation of chromosome aberrations.