PubMed Health⌕ Search

Biomedical subjects

N Mukherjee

Publications and source records attributed to N Mukherjee.

43 records · Page 3Linked to original sources

Cord blood diazepam: clinical effects in neonates of eclamptic mothers.

Diazepam used in the treatment of eclampsia crosses the placental barrier readily, and may cause various clinical effects in the neonates. Twenty-five (25) live born babies of eclamptic mothers receiving diazepam were studied and cord blood diazepam concentration was estimated. Effect of low dose of diazepam is minimal apart from lowering of rectal temperature and the effects lasted for a period of 12 hours. But high dose (> 30 mg) of diazepam and prolonged duration of diazepam therapy in mothers causes significant depression of the newborn and the effects lasted for a period of 36-48 hours. As the clinical condition of the newborn is not related to the diazepam concentration in cord blood, the cord blood estimation is not helpful in the assessment of clinical effects of the drug in newborn. The tissue storage of the drug in newborn appears to be responsible for the clinical effects.

Adult↗

Vitrification of tissue engineered pancreatic substitute.

Despite significant advances, some critical issues remain for the long-term storage of an engineered pancreas. In this study we employed a tissue engineered pancreatic substitute model-insulin-secreting betaTC3 cells entrapped in calcium alginate/poly-L-lysine/alginate beads-to demonstrate that a prototype vitrification method can prevent ice formation and maintain cell viability/function. The results showed that the structure of the frozen samples was distorted by ice crystals throughout the matrix. In marked contrast, the vitrified samples appeared to be free of ice. Morphologic studies demonstrated extensive fractures and vacuolation in frozen specimens while there were no fractures in vitrified TEPSs. Both vitrified and frozen constructs showed some vacuolization compared to the control samples. Frozen beads showed a significantly decreased viability compared to fresh controls and the VS55 group (P < .001). There was no significant difference between the vitrified and fresh samples. Vitrification using the VS55 protocol shows similar viability and secretion properties to the control group of fresh beads. Vitrification using the PEG 400 protocol resulted in slightly lower viability and secretion properties relative to the control group; conventional freezing resulted in even significantly lower viability and secretion properties. These results combine to demonstrate feasibility of vitrification as a storage method for a tissue engineered pancreas.

Animals↗

Human-specific insertion/deletion polymorphisms in Indian populations and their possible evolutionary implications.

DNA samples from 396 unrelated individuals belonging to 14 ethnic populations of India, inhabiting various geographical locations and occupying various positions in the socio-cultural hierarchy, were analysed in respect of 8 human-specific polymorphic insertion/deletion loci. All loci, except Alu CD4, were found to be highly polymorphic in all populations. The levels of average heterozygosities were found to be very high in all populations and, in most populations, also higher than those predicted by the island model of population structure. The coefficient of gene differentiation among Indian populations was found to be higher than populations in most other global regions, except Africa. These results are discussed in the light of two possible scenarios of evolution of Indian populations in the broader context of human evolution.

Alleles↗

Measurement of articular cartilage thickness in the articulated knee.

A radiographic and image analysis method was developed and applied in porcine knees for the measurement of articular cartilage thickness in articulated joints. The feasibility of the approach was assessed by implementing the method for the lateral femoral condyle from harvested limbs. Measurement of the undeformed cartilage thickness with this method was found to have a great degree of precision, with approximately a 1.0% (14 microm) mean variation. Accuracy was also high when compared to an optical method for measuring the true cartilage thickness. An excellent linear correlation (r2>0.99) between the thickness determined optically and that obtained from the radiographic images was demonstrated. No significant differences were found between these two measures of cartilage thickness. This method, which minimizes disturbance to the structures of the knee to maintain its physiologic environment, also has promise to measure the changes in cartilage thickness as the tissue is deformed during joint loading. Information about the undeformed and deformed cartilage thicknesses can be combined with finite element models to examine cartilage behavior from both experimental and theoretical perspectives.

Animals↗