PubMed Health⌕ Search

Biomedical subjects

N Oriuchi

Publications and source records attributed to N Oriuchi.

94 records · Page 6Linked to original sources

Pentavalent technetium-99m dimercaptosuccinic acid uptake in primary amyloidosis: comparison with autopsy findings.

Pentavalent technetium-99m labeled dimercaptosuccinic acid (99mTc(V)-DMSA) scanning was performed on a 71-year-old woman with histologically confirmed primary amyloidosis. Definite uptake of the tracer was noted in the thyroid, liver, spleen, and kidney as well as in the heart. Three months later, she died of heart failure, and autopsy findings demonstrated diffuse deposits of AL-type amyloid in those organs that were consistent with the accumulation of 99mTc(V)-DMSA.

Aged↗

Comparative study of positron emission tomography and quantitative digital radiography (QDR) in detecting effects of aging and diet on bone metabolism of guinea pig.

The purpose of this study was to compare positron emission tomography and quantitative digital radiography (QDR) in detecting the effects of aging and diet on bone metabolism. Bone imaging of guinea pigs was performed with fluorine-18 fluoride ions using a high-resolution animal PET system to analyze bone metabolism quantitatively in different age groups of guinea pigs, young (8 weeks), adult (36 weeks), and aged groups (96 weeks), and also in a dietary manipulation group (low calcium and low vitamin D3 diet for 1, 2, and 3 weeks). A three-compartment kinetic model was applied for the analysis of bone metabolism to evaluate the rate constant (K, K1-K4). There was a significant difference in K-constant between the young and other groups. The K-constant was higher (0.100+/-0.005 ml/min/ml) in the young group than in adults (0.028+/-0.001 ml/min/ml) (p < 0.001) and the aged group (0.047+/-0.020 ml/min/ml). This high value of the K-constant in the young group indicates high turnover in bone metabolism, but there was no significant difference between the adult and aged groups. Bone mineral density (BMD) was lower in the young group (0.15+/-0.026 g/cm2) than in the adult (0.230+/-0.021 g/cm2) (p < 0.001) and aged groups (0.26+/-0.03 g/cm2). There was no significant difference in BMD between the adult and aged groups. Although there was no difference in BMD between the control and dietary manipulation groups, PET study revealed a significant difference in K-constant between them (0.028+/-0.001 vs. 0.090+/-0.009 ml/min/ ml) (p < 0.001). The quantitative skeletal dynamic PET study with 18F fluoride ions was more sensitive and superior in the early detection of metabolic disorders in bone disease than QDR.

Aging↗

99mTc-labeled chimeric anti-NCA 95 antigranulocyte monoclonal antibody for bone marrow imaging.

Chimeric mouse-human antigranulocyte monoclonal antibody (ch MAb) against non-specific cross-reacting antigen (NCA-95) was labeled with 99mTc (using a direct method) and 125I (using the chloramine T method), and its binding to human granulocytes and LS-180 colorectal carcinoma cells expressing carcinoembryonic antigen on their surfaces, cross-reactive with anti-NCA-95 chimeric monoclonal antibody, increased in proportion to the number of cells added and reached more than 80% and 90%, respectively. In biodistribution studies, 99mTc and 125I-labeled ch anti-NCA-95 MAb revealed high tumor uptake, and the tumor-to-blood ratio was 2.9 after 24 hours. The tumor-to-normal-organ ratio was also more than 3.0 in all organs except for the tumor-to-kidney ratio. Scintigrams of athymic nude mice confirmed the results of biodistribution studies that showed higher radioactivity in tumor and kidney of the mice administered with 99mTc-labeled ch MAb. A normal volunteer injected with 99mTc-labeled ch anti-NCA-95 antigranulocyte MAb showed clear bone marrow images, and a patient with aplastic anemia revealed irregular uptake in his lumbar spine, suggesting its utility for bone marrow scintigraphy and for the detection of hematological disorders, infections, and bone metastasis.

Anemia, Aplastic↗

Introducing a downsized, open computer system with asynchronous transfer mode in PACS and its effect on image data transfer.

To assess the effectiveness of the introduction of a downsized, open computer system and asynchronous transfer mode (ATM) as a network in a medium-sized picture archiving and communication system (PACS), we conducted experiments on image data transmission. The speed of image transfer, including registration in the computers in the new PACS, was four to eleven times faster than that in our first PACS. However, the introduction of ATM did not contribute significantly to the improvement of speed of image transfer because of the use of Ethernet branches between the gateway and display workstation computers. A star architecture without Ethernet branches may be suitable for PACS using an ATM network.

Computer Communication Networks↗