Quantification of various growth factors in different demineralized bone matrix preparations.

Besides autografts, allografts, and synthetic materials, demineralized bone matrix (DBM) is used for bone defect filling and treatment of non-unions. Different DBM formulations are introduced in clinic since years. However, little is known about the presents and quantities of growth factors in DBM. Aim of the present study was the quantification of eight growth factors important for bone healing in three different "off the shelf" DBM formulations, which are already in human use: DBX putty, Grafton DBM putty, and AlloMatrix putty. All three DBM formulations are produced from human donor tissue but they differ in the substitutes added. From each of the three products 10 different lots were analyzed. Protein was extracted from the samples with Guanidine HCL/EDTA method and human ELISA kits were used for growth factor quantification. Differences between the three different products were seen in total protein contend and the absolute growth factor values but also a large variability between the different lots was found. The order of the growth factors, however, is almost comparable between the materials. In the three investigated materials FGF basic and BMP-4 were not detectable in any analyzed sample. BMP-2 revealed the highest concentration extractable from the samples with approximately 3.6 microg/g tissue without a significant difference between the three DBM formulations. In DBX putty significantly more TGF-beta1 and FGFa were measurable compared to the two other DBMs. IGF-I revealed the significantly highest value in the AlloMatrix and PDGF in Grafton. No differences were accessed for VEGF. Due to the differences in the growth factor concentration between the individual samples, independently from the product formulation, further analyzes are required to optimize the clinical outcome of the used demineralized bone matrix.

Bone Matrix↗

Quantification of growth factors in allogenic bone grafts extracted with three different methods.

BACKGROUND: Bony allografts are used for defect filling. A reliable sterilization method is the peracetic acid-ethanol sterilization procedure (PES). Several studies showed the antimicrobiological efficacy of this method. Aim of this study was the quantification of growth factors necessary for bone formation in PES sterilized allografts (n = 9). METHODS: To extract the growth factors from the tissue three different methods were used: (a) use of collagenase 1 for extraction, (b) incubation of the material in a proteinase inhibitor cocktail (Complete), and (c) extraction with guanidine HCl. The supernatants from the different methods were analyzed for the total protein concentration and different growth factors. RESULTS: The extraction with guanidine HCl resulted in the highest amount of protein measurable in the supernatants of the samples. For comparison of the individual growth factor values the results were normalized to the protein content. The highest growth factor amount/protein was detectable for BMP-2 using the GndHCL method followed by FGFa, IGF-I, TGF-beta1, VEGF, and PDGF. Comparing the three extraction methods, significant differences were measured for the individual growth factor content. CONCLUSION: PES sterilized bony allografts contain several growth factors. Depending on the extraction method, the quantity of the analyzed growth factors varies.

Bone Transplantation↗

Quantitative assessment of growth factors in reaming aspirate, iliac crest, and platelet preparation.

Large bony defects and non-unions are still a complication in trauma and orthopedic surgery. Treatment strategies include the use of autogenous materials (iliac crest), allogenic bone, bone substitutes, and currently stimulation with growth factors such as BMP-2, BMP-7 or the growth factors containing platelet-rich plasma (PRP). Another source of bone graft material might be the cuttings produced during intramedullary reaming. The aim of this study was to compare the quantity of various growth factors found within iliac crest, bony reaming debris, reaming irrigation fluid, and platelet-rich plasma. Iliac crest and reaming debris and irrigation samples were harvested during surgery. PRP was prepared from blood. The growth factors in the bony materials (iliac crest or reaming debris) and of the liquid materials (platelet-poor plasma (PPP), platelet-rich plasma (PRP) or reaming irrigation) were compared. Elevated levels of FGFa, PDGF, IGF-I, TGF-beta1 and BMP-2 were measured in the reaming debris as compared to iliac crest curettings. However, VEGF and FGFb were significantly lower in the reaming debris than from iliac crest samples. In comparing PRP and PPP all detectable growth factors, except IGF-I, were enhanced in the platelet-rich plasma. In the reaming irrigation FGFa (no measurable value in the PRP) and FGFb were higher, but VEGF, PDGF, IGF-I, TGF-beta1 and BMP-2 were lower compared to PRP. BMP-4 was not measurable in any sample. The bony reaming debris is a rich source of growth factors with a content comparable to that from iliac crest. The irrigation fluid from the reaming also contains growth factors.

Adult↗

[Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

In pelvic and acetabular surgery intraoperative control of reduction and implant position is sometimes hard to achieve with conventional C-arm technology. The Siemens C-arm Iso-C(3D) imaging system enables axial cuts and two- or three-dimensional reconstructions to be generated. Following the good experience in surgery of the spine and extremities, its clinical applicability in pelvic surgery was evaluated in 30 patients in a prospective clinical trial. In all 20 patients with acetabular fractures reduction quality and implant position could be well assessed. In one postoperative examination an intraarticular screw placement was evident, which intraoperatively was not as clear and was revised. In one procedure an intraarticular fragment was visualized, and was extracted in the same procedure. In one procedure the use of the Iso-C(3D) system enabled the approach to be limited. In all ten pelvic ring injuries the osseous structures in the posterior pelvic ring could be visualized with an adequate image quality. Reduction quality and implant position could be assessed in all open and closed procedures. On two occasions the SI screws were navigated based upon the Iso-C(3D) dataset. Overall the use of the Iso-C(3D) system was successful in all cases. Image quality, which is clearly inferior to that of CT, was sufficient for the assessment of reduction quality and implant position. One revision was indicated, and one avoided. However, in spite of its advantages in pelvic surgery, handling, sterile covering and data transfer need to be improved. For bilateral pelvic injuries the image size is too small.

Acetabulum↗

[Traumatic aneurysm of the superior mesenteric artery associated with a burst- fracture of the second lumbar spine -- unforeseen sequelae of a fall from a ladder!].

Traumatic aneurysms of the superior mesenteric artery, although uncommon, are nevertheless life-threatening because of their high risk of rupture. In this case report the aneurysm was accompanied by a burst fracture of the second lumbar spine nearly at the same height. In a prolonged case the diagnosis of the injury was delayed. The clinical manifestation of repeated episodes of abdominal pain did not recur after resection of the aneurysm and interposition of a venous autograft.

Abdomen, Acute↗

[Integrated navigation. Preclinical evaluation and initial clinical experience].

BACKGROUND: Computer navigation systems have increasingly become part of the surgical routine due to the improvements of intraoperative visualization procedures. Because of limited space in the operating room and insufficient workflow, the project of integrated navigation had been started. METHODS: As the first step, the navigation system VectorVision2 and the second-generation fluoroscopic C-arm system Orbic 3D were integrated into one common trolley. In an experimental study the integrated navigation system was used to drill 160 pedicle screws. Afterwards the system was clinically evaluated in 11 surgical procedures. RESULTS: During the whole experimental study the system could be used for all 160 drilling procedures without any technical faults, causing a failure rate of 4.2%. For clinical evaluation the integrated navigation system was used in seven patients with navigated dorsal spine instrumentation, in three cases sacroiliac screws were placed, and in one case supra-acetabular screw osteosynthesis was performed for an acetabular fracture. In all cases the positioning of the screws was correct and no system failure occurred. CONCLUSIONS: The combination of the navigation system and the C-arm system in one common trolley is a major improvement of the surgical workflow. In the experimental study and the clinical trials the system worked extremely reliably and with high precision.

Acetabulum↗

Percutaneous balloon kyphoplasty in the treatment of pathological vertebral body fracture and deformity in multiple myeloma: a one-year follow-up.

PURPOSE: To evaluate the clinical and radiographic outcomes of balloon kyphoplasty in patients with fractures of the thoracic and lumbar spine caused by multiple myeloma. MATERIAL AND METHODS: Vertebral fractures due to multiple myeloma were treated by balloon kyphoplasty (20 patients, 48 vertebral bodies). Symptomatic levels were identified by clinical presentation, magnetic resonance imaging (MRI), radiographs, and computed tomography (CT). During the following year, visual analog scale (VAS) and Oswestry disability score were documented. Radiographs were taken pre- and postoperatively at 3, 6, and 12 months. Vertebral height and kyphotic deformity were measured to assess restoration of the sagittal alignment. RESULTS: The median pain scores (VAS) decreased significantly from pre- to posttreatment, as did the Oswestry disability score (p < 0.05). Clinically asymptomatic cement leakage occurred at 5 fracture levels (10.4%). During 1-year follow-up, this surgical technique demonstrated restoration and stabilization of the height of the vertebral body. CONCLUSION: Balloon kyphoplasty is an effective minimally invasive procedure for stabilizing pathological vertebral fractures caused by multiple myeloma and leading to a statistically significant reduction of pain status. Balloon kyphoplasty stabilizes the vertebral body height, but is only partially able to prevent further kyphotic deformities.

Aged↗

Stabilisation of periprosthetic fractures with angular stable internal fixation: a report of 13 cases.

INTRODUCTION: Periprosthetic fractures of the femur present a challenging surgical problem. The aim of this study was to retrospectively evaluate the outcome of periprosthetic fractures stabilised with an angular stable, less invasive stabilisation system (LISS). PATIENTS AND METHODS: Thirteen patients (ten total hip-, two total knee-, one total hip- and knee-arthroplasty) with periprosthetic fractures were treated with the LISS internal fixator (in ten cases minimal invasive). Six patients had previous operations due to periprosthetic fractures. The average follow-up period was 20 months, follow-up rate 85%. RESULTS: All fractures showed radiographic fracture healing without implant loosening. Except one patient, all patients had returned to their pre-operative activity level. No early post-operative complications were seen. There was one implant failure after 4 months and two cases of malunion. CONCLUSION: The cases showed the internal fixator to be effective for the stabilisation of periprosthetic fractures, even in cases of poor bone quality with good functional outcomes. The internal fixator, with the option of minimal invasive application, is the preferred method of osteosynthesis in periprosthetic fractures.

Accidental Falls↗

Systemic versus local application of gentamicin in prophylaxis of implant-related osteomyelitis in a rat model.

Administration of perioperative antibiotic prophylaxis is a routine procedure in orthopedic surgery. Besides systemic prophylaxis, only few techniques are established for local application of antibiotics to reduce infection related to orthopedic implants. The aim of this study was to evaluate the efficacy of locally versus systemically applied gentamicin in a rat model (n = 60). For local application, the antibiotic was delivered from a biodegradable poly(D,L-lactide) (PDLLA) coating of titanium implants. The efficacy of local prophylaxis was compared to a systemic single shot application of gentamicin as well as a combination of both administrations. Half of the animals received a weight-adopted single shot application of gentamicin 30 min prior to surgery. At surgery, the medullary cavities of the tibiae were contaminated with Staphylococcus aureus (10(2) colony forming units /CFU) and titanium Kirschner wires were implanted into the medullary canals. The implants were either uncoated, PDLLA coated, or coated with PDLLA + 10% w/w gentamicin. The animals were followed up for 42 days. X-ray examinations were performed; body weight, temperature, and the clinical condition were determined. After sacrifice, infection was evaluated by histological and microbiological analysis. All animals treated with uncoated or PDLLA-coated Kirschner wires without systemic application of the antibiotic developed osteomyelitis and all cultures of implants were tested positive on S. aureus. Implant-related osteomyelitis could be prevented by prophylaxis of systemically applied gentamicin in 15% of animals. In contrast, local application of gentamicin delivered from a PDLLA coating was more effective. Onset of infection could be prevented in 90% of animals treated with gentamicin coated Kirschner wires, and in 80% of the animals that were treated with a combination of local and systemic application. The local application from PDLLA-coated implants might support systemic antibiotic prophylaxis in preventing implant-associated osteomyelitis.

Animals↗

Determination of muscle loading at the hip joint for use in pre-clinical testing.

The stability of joint endoprostheses depends on the loading conditions to which the implant-bone complex is exposed. Due to a lack of appropriate muscle force data, less complex loading conditions tend to be considered in vitro. The goal of this study was to develop a load profile that better simulates the in vivo loading conditions of a "typical" total hip replacement patient and considers the interdependence of muscle and joint forces. The development of the load profile was based on a computer model of the lower extremities that has been validated against in vivo data. This model was simplified by grouping functionally similar hip muscles. Muscle and joint contact forces were computed for an average data set of up to four patients throughout walking and stair climbing. The calculated hip contact forces were compared to the average of the in vivo measured forces. The final derived load profile included the forces of up to four muscles at the instances of maximum in vivo hip joint loading during both walking and stair climbing. The hip contact forces differed by less than 10% from the peak in vivo value for a "typical" patient. The derived load profile presented here is the first that is based on validated musculoskeletal analyses and seems achievable in an in vitro test set-up. It should therefore form the basis for further standardisation of pre-clinical testing by providing a more realistic approximation of physiological loading conditions.

Computer Simulation↗

[Diagnostic value of MR analysis of cartilaginous lesions compared with intraoperative arthroscopy in calcaneal fractures].

PURPOSE: To determine the diagnostic value of MRI in preoperative analysis and classification of cartilaginous lesions - especially of the posterior facet - in traumatic calcaneal fractures compared with intraoperative arthroscopy. MATERIALS AND METHODS: Twenty-four consecutive patients with traumatic calcaneal fractures underwent prospective MRI of the subtalar joint surface using T1- and T2-weighted spin echo sequences and fat suppressed 3D gradient echo sequences in semicoronal slice orientation (1.5 T MRI). After randomization, the images were analyzed by two blinded and independent readers experienced in MRI. The results were compared with the intraoperative arthroscopic findings as to location and depth of the defects using the Outerbridge classification. RESULTS: We examined 12 calcaneal fractures of type 2, 8 of type 3 and 4 of type 4 according to the Sanders classification. With respect to principal detection and exact classification, 67 of 96 (69.8 %) of all arthroscopic verified cartilaginous defects were diagnosed correctly by MRI. Disregarding the degree of the defects, 38 of 44 (86.4 %) chondral lesions were detected (sensitivity: 86.4 %, specificity: 86.5 %, diagnostic accuracy: 86.5 %). Considering the chondral lesions of degrees 3 and 4 together, the sensitivity was 86.0 %, the specificity 86.8 %, and the diagnostic accuracy 86.5 % . Assessing these degrees separately, the sensitivity was only 33.3 % for degree 3 and 58.1 % for degree 4, whereas the specificity was definitely higher with 82.1 % for degree 3 and 89.2 % for degree 4. CONCLUSION: The MR detection of cartilaginous defects in calcaneal fractures has a sufficient diagnostic accuracy for planning the surgical intervention and assessing the long-term postsurgical prognosis.

Adult↗

Angle stable locking reduces interfragmentary movements and promotes healing after unreamed nailing. Study of a displaced osteotomy model in sheep tibiae.

BACKGROUND: Large interfragmentary movements may delay bone-healing. The hypothesis of the present study was that a reduction of interfragmentary movements, especially of torsional rotation and bending angles, would support the healing process and lead to improved healing following unreamed tibial nailing. The objective of this study was to investigate healing of an unstable tibial osteotomy site following stabilization with unreamed nailing with a modified tibial device that had angle stable holes for the locking bolts. We compared those findings with healing after stabilization of such sites with standard unreamed tibial nailing. The duration of the study period was nine weeks. METHODS: The site of a standardized displaced osteotomy (3-mm gap) in twelve ovine tibiae was stabilized with unreamed tibial nailing: six animals were treated with a modified nail that had angle stable holes for the locking bolts, and six were treated with standard unreamed tibial nailing. In vivo gait analysis with optical measurements of interfragmentary movements and simultaneous measurements of ground reaction parameters were performed three days after the operation and once weekly afterward. After the animals were killed at nine weeks, the treated and contralateral tibiae were explanted, the implants were removed, and radiographs were made and evaluated for bridged cortices. Each pair of tibiae was also mechanically tested until torsional failure, after which the whole callus region was subjected to histological and histomorphometric analysis. RESULTS: Throughout the examination period, the interfragmentary movements in all directions were significantly smaller in the group treated with the angle stable tibial nail than they were in the group treated with standard unreamed tibial nailing. The limbs treated with the angle stable tibial nails returned to almost full weight-bearing during the period of the investigation, whereas those treated with standard nailing did not. Histomorphometric analysis, radiographic data, and mechanical testing showed superior bone-healing following treatment with the angle stable tibial nail. CONCLUSIONS: Use of an angle stable tibial nail may help to reduce interfragmentary movements in vivo and thus lead to superior bone-healing compared with that following standard unreamed tibial nailing.

Analysis of Variance↗

Differences in the fusion and resorption activity of human osteoclasts after stimulation with different growth factors released from a polylactide carrier.

Previous in vivo studies were able to demonstrate the efficacy of locally released growth factors IGF-I, TGF-beta1, and BMP-2 from a poly(D,L-lactide) (PDLLA) implant coating on fracture healing. In vitro studies using human osteoblast-like cells showed an enhanced collagen-1 production due to growth factor application without an effect of the PDLLA on the investigated parameter. Both bone-forming osteoblasts and bone-resorbing osteoclasts are important during bone formation and fracture healing. The aim of this study was to investigate the influence of different growth factors and the polylactide coating into which they were incorporated on isolated osteoclasts. In vitro studies using human osteoclast-like cells derived from peripheral blood mononuclear cells (PBMNCs) were performed. Titanium K-wires coated with the lactide loaded with IGF-I and TGF-beta1 (alone and in combination) or BMP-2 were added to the culture in a non-contact manner and the fusion, resorption activity (pit formation assay), and TRAP 5b synthesis of the cells were analyzed. Differences in the effect of the growth factors were seen depending on the differentiation state of the cells. The fusion of the monocytes to multinuclear osteoclasts was significantly enhanced by the application of TGF-beta1 both alone and in combination with IGF-I. No effect was seen after application of IGF-I alone or BMP-2. The resorption activity of the osteoclasts analyzed on dentine chips was significantly enhanced after application of TGF-beta1 or BMP-2. These results indicate a differentiation-dependent effect of growth factors on osteoclasts. TGF-beta1 affects both the osteoclastogenesis and the activity of osteoclasts, whereas BMP-2 had an effect only on the activity of mature osteoclasts but not on the fusion of the PBMNCs.

Acid Phosphatase↗

Local and controlled release of growth factors (combination of IGF-I and TGF-beta I, and BMP-2 alone) from a polylactide coating of titanium implants does not lead to ectopic bone formation in sheep muscle.

The osteoinductive potential of growth factors leads not only to a stimulated bone formation in bony tissue but also in extra skeletal tissue. This potential depends on the dosage and potentially on the application method and may limit the clinical use. The aim of the present study was to investigate the potential of IGF-I, TGF-beta1 and BMP-2 released from a newly developed application systems of orthopaedic implants to induce ectopic bone formation in muscles. This bioactive coating showed a stimulating effect on fracture healing in several experimental studies before. Titanium discs were coated on one side with the drug carrier poly(d,l-lactide) (PDLLA), with the carrier plus IGF-I and TGF-beta1 or with the carrier plus BMP-2. The discs were implanted in the Musculus cleidomastoideus of sheep and followed up for 3 months. X-rays were taken after the operation and the day of sacrifice. The muscles plus implant were harvested and prepared for histology. Neither the radiology nor the histology revealed any signs of ectopic ossification in the implant/muscle interface or in a distance to the plate in any group. An influence of the locally applied growth factor, however, was seen in the formation of a soft tissue capsule. Histomorphometric analysis revealed a significantly larger capsule area over the growth factor coated side in comparison to the uncoated side or the pure titanium plate, indicating an effect of the applied growth factors on cells, however, not resulting in osteoinduction in muscle. The result showed that the local and controlled release of growth factors from PDLLA coated implants does not induce ectopic bone formation in sheep muscle and could be used in orthopaedic surgery to increase healing without the risk of ectopic bone formation in the surrounding soft tissue.

Animals↗

[Expandable cages: biomechanical comparison of different cages for ventral spondylodesis in the thoracolumbar spine].

INTRODUCTION: Due to a recent increase in the commercial availability of expandable cages for vertebral body replacement, this study was designed to gain more information about their biomechanical properties. All three expandable cages evaluated in this study are approved for clinical use, but little knowledge about their biomechanical properties exists. MATERIAL AND METHODS: Human thoracolumbar spines (T11 to L3) ( n=32) were tested in flexion, extension, axial rotation, and lateral bending with a nondestructive stiffness method. Three-dimensional displacement was measured using an optical measurement system. All motion segments were tested intact. After L1 corporectomy, cages were implanted and the following groups ( n=8 each) were tested: (1) meshed titanium cage (nonexpandable cage, DePuy Acromed), (2) X-tenz (expandable cage, DePuy Acromed), (3) Synex (expandable Cage, Synthes), and (4) VBR (expandable cage, Ulrich). Finally, posterior stabilization and posterior-anterior stabilization, both using USS (Synthes), and anterior plating (LCDCP, Synthes) was applied. The mean apparent stiffness values, ranges of motion, and neutral and elastic zones were calculated from the corresponding load/displacement curves. RESULTS: No significant differences were found between the in vitro biomechanical properties of expandable and nonexpandable cages. Compared to the intact motion segment, isolated anterior stabilization using cages and anterior plating significantly decreased stiffness and increased range of motion in all directions. Additional posterior stabilization significantly increased stiffness and decreased range of motion in all directions compared to the intact motion segment. Combined anterior-posterior stabilization demonstrated the greatest stiffness results. CONCLUSION: Design variations of expandable cages for vertebral body replacement do not show any significant effect on the biomechanical results. There was no significant difference found, between the biomechanical properties of expandable and non-expandable cages. After corporectomy, isolated implantation of expandable cages plus anterior plating was not able to restore normal stability of the motion segment. As a consequence, isolated anterior stabilization using cages plus LCDCP should not be used for vertebral body replacement in the thoraco-lumbar spine.

Biomechanical Phenomena↗

[The multidisciplinary approach to reconstructive surgery of the extremities-considerations for trauma and orthopedic surgery].

Interdisciplinary reconstructive surgery of the extremities involves a variety of indications ranging from IIIB/C open fractures with major segmental loss of bone and soft tissue, to arterial vessel injury necessitating vascular repair, and to biological, plastic reconstruction following resection of musculoskeletal tumors. The multidisciplinary approach involving trauma/orthopedic surgery combined with vascular, plastic, and neuro- resp. microsurgery has significantly increased the rate of limb-sparing operations and improved morbidity, function, quality of life, and long-term oncological outcome. The multidisciplinary treatment of both complex trauma and malignant bone/soft tissue sarcoma of the extremity is an integral task of surgical trauma and tumor centers. Close interactive communication between the individual surgical disciplines has decisively influenced prognosis and is the precondition for priority-adapted therapeutic strategies.

Amputation, Surgical↗

[Biodegradable cage. Osteointegration in spondylodesis of the sheep cervical spine].

Bioabsorbable implants are commonplace in knee and shoulder surgery. Bioabsorbable poly(l-lactide-co-D,L-lactide) (PLDLLA) cage devices have potential benefits over autologous tricortical iliac crest bone graft and metallic cages for cervical spine interbody fusion. The purpose of this study was to compare interbody fusion of an autologous tricortical iliac crest bone graft with that of a bioabsorbable cage using a sheep cervical spine interbody fusion model. This study was designed to determine differences in (1) the ability to preserve postoperative distraction, (2) biomechanical stability, and (3) histological characteristics of intervertebral bone matrix formation. Sixteen full-grown Merino sheep underwent C3/4 discectomy and fusion. After 12 weeks, there was no significant difference between the results with the bioabsorbable PLDLLA cages and tricortical bone grafts. The cage also did not show advanced interbody fusion but did, however, show large osteolysis, which allows skepticism regarding the value of this bioabsorbable implant.

Absorbable Implants↗