PubMed Health⌕ Search

Biomedical subjects

N Pallikarakis

Publications and source records attributed to N Pallikarakis.

At least 19 recordsLinked to original sources

Dual-energy mammography: simulation studies.

This paper presents a mammography simulator and demonstrates its applicability in feasibility studies in dual-energy (DE) subtraction mammography. This mammography simulator is an evolution of a previously presented x-ray imaging simulation system, which has been extended with new functionalities that are specific for DE simulations. The new features include incident exposure and dose calculations, the implementation of a DE subtraction algorithm as well as amendments to the detector and source modelling. The system was then verified by simulating experiments and comparing their results against published data. The simulator was used to carry out a feasibility study of the applicability of DE techniques in mammography, and more precisely to examine whether this modality could result in better visualization and detection of microcalcifications. Investigations were carried out using a 3D breast software phantom of average thickness, monoenergetic and polyenergetic beam spectra and various detector configurations. Dual-shot techniques were simulated. Results showed the advantage of using monoenergetic in comparison with polyenergetic beams. Optimization studies with monochromatic sources were carried out to obtain the optimal low and high incident energies, based on the assessment of the figure of merit of the simulated microcalcifications in the subtracted images. The results of the simulation study with the optimal energies demonstrated that the use of the DE technique can improve visualization and increase detectability, allowing identification of microcalcifications of sizes as small as 200 microm. The quantitative results are also verified by means of a visual inspection of the synthetic images.

Algorithms↗

Simulation studies of field shaping in rotational radiation therapy.

This article presents simulation studies of field shaping in rotational radiation therapy by means of two categories of beam modifying devices: protectors and shapers. The protectors used are diminished copies of the organs at risk (OARs) and stay parallel to them during gantry rotation. Thus, each protector always keeps the corresponding OAR in its shadow, significantly reducing the irradiation. The shapers are used in order to obtain a more uniform dose distribution in the planning target volume (PTV) while preserving their initial orientation during gantry rotation. Thus, the use of beam modifying devices allows modulation of the beam intensity, to better fit irradiation requirements, at every gantry position. A software tool for calculations of geometrical position and dimensions of the beam modifying devices, using information about the shape, size, and position of the protected organ or area at risk as input, was developed. This tool was integrated into the in-house-developed Monte Carlo radiation therapy simulator (MCRTS), used to simulate the particle transport through the designed system. The verification of the software tool showed good agreement between experimental and simulation data, with discrepancies of less than 3%. Dose distributions in solid-geometry and voxel-based neck models were evaluated. Furthermore, the effectiveness of the shapers to modify the dose distribution outside the protected area was studied. Results demonstrated that the use of the shapers effectively improves dose uniformity. Studies using shapers of different materials were also carried out and resulted in similar dose distributions. The results of the simulation studies with a voxel-based model showed that rotational therapy with beam modifying devices offers adequate protection of the OAR and a uniform dose distribution outside the protected region.

Algorithms↗

Development and evaluation of an ODL course on Medical Image Processing.

Recent developments in the field of Biomedical Engineering have led to considerable improvement in health care delivery, but also impose continuous change and improvement in education and training schemes of its professionals, in order to assure appropriate front-line knowledge, competencies and skills. Open and distance learning provides a very effective means for continuous education and training purposes. Image processing may be used as an attractive case for exploring the Collaborative Learning Model (CLM) paradigm in Open Distance Learning (ODL). An on-line course on Medical Image Processing, following the principles of collaborative learning, has been developed and evaluated. Each concept of the course is available in three levels of complexity. The first level shows only a very general description, actually the main idea. If the user is interested to continue, a second level is accessible, where the concept is explained in a more detailed manner. Moreover, for some concepts requiring complicated mathematical proofs, a third level is available. The course has been used at the European Course on Biomedical Engineering organized by the Department of Medical Physics, University of Patras, Greece, and was positively evaluated by the students.

Biomedical Engineering↗

A three-dimensional breast software phantom for mammography simulation.

This paper presents a methodology for three-dimensional (3D) computer modelling of the breast, using a combination of 3D geometrical primitives and voxel matrices that can be further subjected to simulated x-ray imaging, to produce synthetic mammograms. The breast phantom is a composite model of the breast and includes the breast surface, the duct system and terminal ductal lobular units. Cooper's ligaments, the pectoral muscle, the 3D mammographic background and breast abnormalities. A second analytical x-ray matter interaction modelling module is used to generate synthetic images from monoenergetic fan beams. Mammographic images of various synthesized breast models differing in size, shape and composition were produced. A preliminary qualitative assessment performed by three radiologists and a quantitative evaluation study using fractal and grey-level histogram analysis were conducted. A comparative study of extracted features with published data has also been performed. The evaluation results indicated good correlation of characteristics between synthetic and actual radiographs. Applications foreseen are not only in the area of breast imaging experimentation but also in education and training.

Breast↗

An integrated research tool for X-ray imaging simulation.

This paper presents a software simulation package of the entire X-ray projection radiography process including beam generation, absorber structure and composition, irradiation set up, radiation transport through the absorbing medium, image formation and dose calculation. Phantoms are created as composite objects from geometrical or voxelized primitives and can be subjected to simulated irradiation process. The acquired projection images represent the two-dimensional spatial distribution of the energy absorbed in the detector and are formed at any geometry, taking into account energy spectrum, beam geometry and detector response. This software tool is the evolution of a previously presented system, with new functionalities, user interface and an expanded range of applications. This has been achieved mainly by the use of combinatorial geometry for phantom design and the implementation of a Monte Carlo code for the simulation of the radiation interaction at the absorber and the detector.

Computer Simulation↗

Image quality in extended arc filtered digital tomosynthesis.

PURPOSE: To study image quality in filtered digital tomosynthesis (FDTS) tomograms as a function of their reconstruction arc, using isocentrically acquired, fluoroscopic projection data. MATERIAL AND METHODS: Both digital tomosynthesis (DTS) and cone beam CT (CBCT) reconstruction algorithms are based on backprojection and use cone beam projection data as input. Under limited angle conditions, CBCT is reduced to FDTS, where only a subset of projection data are used for reconstruction. The effect of the reconstruction arc on the spatial resolution, slice thickness, contrast sensitivity, shape distortion and artifacts, was also experimentally studied. The investigation was performed using both simulated and actual fluoroscopic images. RESULTS AND CONCLUSION: Image quality in terms of spatial resolution, slice thickness, shape distortion and artifacts, improved with increasing reconstruction arc and was optimized at 180 degrees, while contrast continued to improve as the arc was increased to 360 degrees. However, DTS was determined to be the technique of choice when reconstruction arcs of less than 40 degrees were used. Consequently, FDTS may be successfully implemented in applications involving extended arc reconstructions, in the range between 40 degrees delimiting the DTS domain and 360 degrees corresponding to CBCT.

Image Processing, Computer-Assisted↗

A software data generator for radiographic imaging investigations.

A software data generation tool, intended to be used in radiographic applications, has been developed. The application integrates a phantom design module and an imaging simulator. Phantoms can be described as a set of either geometrical objects or voxels, or contours drawn on multiple tomographic slices. Radiographic projections of the phantoms are formed on the basis of a simulated irradiation process, with selectable imaging parameters. Comparison between actual projection images from a physical and a simulated phantom shows good correspondence. The application was used for digital tomosynthesis (DTS) investigations and has proven to be a useful tool in the study of tomographic noise. Further development is expected to expand the use of the application to more areas of radiological imaging research.

Algorithms↗

Education in biomedical engineering: experience from a European ERASMUS program.

Based on recent advances in biomedical research and the developments of new equipment and techniques, the field of Biomedical Engineering and Health Care Telematics are currently undergoing a rapid evolution characterized by an increasing degree of specialization. This, in turns, imposes new requirements in advanced education, while the changing scene at European level, introduces a major challenge for harmonization and standardization of education with a focus on meeting the emerging needs. At the same time information technologies provide new means and tools supporting the educational and training activities. An initiative for the development of a multinational advanced course in Biomedical Engineering, is implemented in the University of Patras with extended collaboration of European Universities, providing a unique case for achievement of excellency. In order to take full advantage of this potential, a Quality Assurance system has been designed and implemented over the past four years, aiming to provide the appropriate framework for mutual recognition amongst the participating institutions. Additionally, the implementation of new telematic tools is scheduled for the near future, in order to provide the Course with teleconference facilities and allow a much larger number of students to remotely attend the lectures.

Biomedical Engineering↗

An integrated system for the production of field shaping devices in radiotherapy.

A system has been developed in our department that simplifies the production processes of field shaping devices in radiotherapy, integrating an image grabbing and processing facility at a radiotherapy simulator and an automated block cutter. The data acquisition subsystem captures images, processes and corrects them for pincushion distortions, creates a composite radiograph, records user defined contours of blocks and exports data to the block cutter controller. A robotic subsystem drives and controls the polystyrene cutting unit. The system has been experimentally evaluated. Errors in contour definition were found to be less than 1 mm for a broad range of gantry angles and not exceeding 1.5 mm for those gantry orientations that present maximum magnetic field related image intensifier distortion, while the automated block cutter is capable of cutting out contours in polystyrene with an accuracy comparable to that of commercially available systems. The system is expected to contribute to the overall improvement of radiotherapy processes, particularly in low budget radiotherapy departments, introducing improvements in accuracy and efficiency at minimum costs.

Cost Control↗

Three-dimensional localisation based on projectional and tomographic image correlation: an application for digital tomosynthesis.

Accurate three-dimensional tumor localisation in Radiotherapy, is critical to the treatment outcome, particularly when high dose gradients are present. A number of techniques have been proposed for the localisation of anatomical structures or markers. The present study proposes an approach to a concurrent maximisation of localisation accuracy and efficiency by correlation of tomographic and projectional images. The method introduces an element of direct verification and interactive optimisation of the process. Tomographic images are used for the identification of a point of interest. Its position is computed within the treatment co-ordinate system and verification of this position is achieved by obtaining the beam's eye view of the identified point on two projection radiographs. The key element of the approach is that all images used should be part of one single image data set. The implementation of this localisation method, as part of the functionality of a Digital Tomosynthesis prototype, has provided an integrated facility for localisation, of optimised accuracy and precision, while easy and efficient to use. The considerations are general and apply in principle to any imaging system that can augment tomographic images with projections.

Algorithms↗

Monte Carlo simulation of the radiographic imaging procedure for electronically designed phantoms.

This paper presents a software simulation package of the entire X-ray projection radiography process including beam generation, absorber structure and composition, irradiation set up, radiation transport through the absorbing medium and image formation. This software tool is an augmented version of a previously presented system with expanded range of application by the implementation of Monte Carlo approach for the simulation of the radiation interaction at the absorber and the detector. Phantoms are created as composite objects from geometrical or voxelized primitives and can be subjected to simulated irradiation process. The acquired projection images represent the two dimensional spatial distribution of the energy absorbed in the detector and are formed at any geometry, taking into account energy spectrum, beam geometry and detector response.

Computer Simulation↗

A protocol building software tool for medical device quality control tests.

Q-Pro is an application for Quality Control and Inspection of Medical Devices. General system requirements include friendly and comprehensive graphical environment and proper, quick, easy and intuitive user interface. Functions such as, a tool library for protocol design widely used multimedia, as well as, a support of a local database for protocol and inventory data archiving are provided by the system. In order to serve the different categories of users, involved in Quality Control procedures, the system has been split into three modules of different functionality and complexity, each of which can work as a stand-alone application. The implementation of protocols and use of the software functions, as well as, the user interface itself have been proved by the evaluators to be clear and intuitive. The software seems to adapt easily to different kinds of Quality Control procedures and objectives. Q-Pro effectively supports and enhances the processes to attain a highly tuned, professional, responsive and effective quality control and preventive maintenance procedures for biomedical equipment management.

Data Collection↗

In-house development of test equipment for quality control and training. Case study: a prototype ECG simulator-tester.

The support services for biomedical technology address a variety of technical and administrative issues, concerning the safe and efficient operation of medical equipment over the period of its intended use and the training of hospital personnel in issues concerning safety and quality. Clinical Engineering Departments undertake the responsibility of developing and operating training programs in medical equipment utilisation apart from the traditional role of training and supervising technicians involved in testing, calibration and preventive/corrective maintenance of electromedical equipment. In view of the above, the Institute of Biomedical Technology and the Centre of Biomedical Engineering collaborated for the design and development of a prototype digital ECG and arrhythmia simulator. In the absence of internationally accepted inspection protocols for ECG simulators, the verification phase of the project involved mainly the inspection of the device's conformity to its initial technical specifications. The results demonstrated that this tester. due to simplicity in construction and easiness of use could be a practical, reliable and economical solution for electrocardiograph and ECG monitor testing and waveform recognition training.

Arrhythmias, Cardiac↗

Volume imaging in fluoroscopy. A clinical prototype system based on a generalized digital tomosynthesis technique.

PURPOSE: This work involves the development of a new digital tomosynthesis technique into a clinical prototype imaging system for the three-dimensional visualization of patient anatomy. MATERIAL AND METHODS: The multiple projection algorithm (MPA) has been developed into a clinical prototype imaging system comprising a digital chain that is interfaced with an isocentric fluoroscopic unit to form an integrated DTS facility. Planes of varying orientations can be synthesized retrospectively on the basis of an acquired set of appropriate projection images extending over the whole volume of interest. RESULTS AND CONCLUSION: The system provides an image reconstruction and processing facility that can effectively augment fluoroscopic examinations. Reconstruction times of a few seconds per plane have been achieved. The region of interest can be approached by tracking through cross-sections with user-selected orientations. Anatomical planes of particular interest can be identified and their reconstructed images can be stored. The characteristics of the image presentation modality have the potential to extend the field of current digital tomosynthesis applications to new areas in radiology and other clinical domains.

Algorithms↗

Radiographic skills learning: procedure simulation using adaptive hypermedia.

The design and development of a simulation tool supporting learning of radiographic skills is reported. This tool has by textual, graphical and iconic resources, organized according to a building-block, adaptive hypermedia approach, which is described and supported by an image base of radiographs. It offers interactive user-controlled simulation of radiographic imaging procedures. The development is based on a commercially available environment (Toolbook 3.0, Asymetrix Corporation). The core of the system is an attributed precedence (priority) graph, which represents a task outline (concept and resources structure), which is dynamically adjusted to selected procedures. The user interface imitates a conventional radiography system, i.e. operating console, tube, table, patient and cassette. System parameters, such as patient positioning, focus-to-patient distance, magnification, field dimensions, tube voltage and mAs are under user control. Their effects on image quality are presented, by means of an image base acquired under controlled exposure conditions. Innovative use of hypermedia, computer based learning and simulation principles and technology in the development of this tool resulted in an enhanced interactive environment providing radiographic parameter control and visualization of parameter effects on image quality.

Computer Simulation↗