PubMed Health⌕ Search

Biomedical subjects

N Pierrat

Publications and source records attributed to N Pierrat.

2 recordsLinked to original sources

Current developments at IRSN on computational tools dedicated to assessing doses for both internal and external exposure.

The paper presents the OEDIPE (French acronym that stands for tool for personalised internal dose assessment) and SESAME (for simulation of external source accident with medical images) computational tools, dedicated to internal and external dose assessment, respectively, and currently being developed at the Institute for Radiological Protection and Nuclear Safety. The originality of OEDIPE and SESAME, by using voxel phantoms in association with Monte Carlo codes, lies in their ability to construct personalised voxel phantoms from medical images and automatically generate the Monte Carlo input file and visualise the expected results. OEDIPE simulates in vivo measurements to improve their calibration, and calculates the dose distribution taking both internal contamination and internal radiotherapy cases into account. SESAME enables radiological overexposure doses to be reconstructed, as also victim, source and accident environment modelling. The paper presents the principles on which these tools function and an overview of specificities and results linked to their fields of application.

Academies and Institutes↗

Application of Monte Carlo calculations to calibration of anthropomorphic phantoms used for activity assessment of actinides in lungs.

This paper reports on a new utility for development of computational phantoms for Monte Carlo calculations and data analysis for in vivo measurements of radionuclides deposited in tissues. The individual parameters of each worker can be acquired for an exact geometric representation of his or her anatomy, which is particularly important for low-energy gamma ray emitting sources such as thorium, uranium, plutonium and other actinides. The software discussed here enables automatic creation of an MCNP input data file based on computed tomography (CT) scanning data. The utility was first tested for low- and medium-energy actinide emitters on Livermore phantoms, the mannequins generally used for lung counting, in order to compare the results of simulation and measurement. From these results, the utility's ability to study uncertainties in in vivo calibration were investigated. Calculations and comparison with the experimental data are presented and discussed in this paper.

Actinoid Series Elements↗