PubMed Health⌕ Search

Biomedical subjects

N Poli

Publications and source records attributed to N Poli.

5 recordsLinked to original sources

Long-lived BLOCH oscillations with bosonic sr atoms and application to gravity measurement at the micrometer scale.

We report on the observation of Bloch oscillations on the unprecedented time scale of several seconds. The experiment is carried out with ultracold bosonic 88Sr atoms loaded into a vertical optical standing wave. The negligible atom-atom elastic cross section and zero angular momentum in the ground state makes 88Sr an almost ideal Bose gas, insensitive to typical mechanisms of decoherence due to thermalization and external stray fields. The small size of the system enables precision measurements of forces at micrometer scale. This is a challenge in physics for studies of surfaces, Casimir effects, and searches for deviations from Newtonian gravity predicted by theories beyond the standard model.

Journal Article↗

Laser sources for precision spectroscopy on atomic strontium.

We present a new laser setup designed for high-precision spectroscopy on laser cooled atomic strontium. The system, which is entirely based on semiconductor laser sources, delivers 200 mW at 461 nm for cooling and trapping atomic strontium from a thermal source, 4 mW at 497 nm for optical pumping from the metastable P23 state, 12 mW at 689 nm on linewidth less than 1 kHz for second-stage cooling of the atomic sample down to the recoil limit, 1.2 W at 922 nm for optical trapping close to the "magic wavelength" for the 0-1 intercombination line at 689 nm. The 689 nm laser was already employed to perform a frequency measurement of the 0-1 intercombination line with a relative accuracy of 2.3 x 10(-11), and the ensemble of laser sources allowed the loading in a conservative dipole trap of multi-isotopes strontium mixtures. The simple and compact setup developed represents one of the first steps towards the realization of a transportable optical standards referenced to atomic strontium.

Lasers↗

Direct demonstration of decoupling of spin and charge currents in nanostructures.

The notion of decoupling of spin and charge currents is one of the basic principles underlying the rapidly expanding field of spintronics. However, no direct demonstration of the phenomenon exists. We report a novel measurement in which a nonequilibrium spin population is created by a pointlike injection of current from a ferromagnet across a tunnel barrier into a one-dimensional spin channel and detected differentially by a pair of ferromagnetic electrodes placed symmetrically about the injection point. We demonstrate that the spin current is strictly isotropic about the injection point and, therefore, completely decoupled from the unidirectional charge current.

Computer Simulation↗

Precision frequency measurement of visible intercombination lines of strontium.

We report the direct frequency measurement of the visible 5s(2) 1S0-5s5p 3P1 intercombination line of strontium that is considered a possible candidate for a future optical-frequency standard. The frequency of a cavity-stabilized laser is locked to the saturated fluorescence in a thermal Sr atomic beam and is measured with an optical-frequency comb generator referenced to the SI second through a global positioning system signal. The 88Sr transition is measured to be at 434 829 121 311 (10) kHz. We measure also the 88Sr-86Sr isotope shift to be 163 817.4 (0.2) kHz.

Journal Article↗

[Evaluation of the efficacy of a program to control nosocomial spread of methicillin-resistant Staphylococcus aureus].

OBJECTIVE: To evaluate the efficacy of a program to control nosocomial spread of methicillin-resistant Staphylococcus aureus (MRSA). METHODS: Analysis of the incidence of infection and contamination due to MRSA in patients admitted to the hospital of Cremona 6 months before and 3 years after the introduction of the guidelines (July 1997). RESULTS: During the 42 months of the study period, on 80705 admissions, 511 cases of MRSA contamination/infection were identified, the incidence being 0.57 cases per 100 admissions. The infection rate dropped from 0.34 (IC95%: 0.25-0.45) in the first 6 months of the study, before the introduction of guidelines, to 0.17 (IC95%: 0.14-0.20) in the following 3 years (p=0.01). Severe infection decreased from 0.18 to 0.1 per 100 admissions, with a 44% decrease (p=0.058), while mild infections diminished from 0.16 to 0.07 per 100 admissions (p=0.045). Methicillin resistance among nosocomial isolates of Staphylococcus aureus was reduced from 53 % to 35 % (p<0.0001). CONCLUSIONS: The introduction of a program to control the nosocomial spread of MRSA proved effective in reducing both the incidence of infection and the methicillin-resistance of Staphylococcus aureus isolates. The cost effectiveness of the program seems very favourable.

Body Fluids↗