PubMed Health⌕ Search

Biomedical subjects

N Proust

Publications and source records attributed to N Proust.

3 recordsLinked to original sources

Phosphine sampling and analysis using silver nitrate impregnated filters.

In the field of industrial hygiene, besides the necessity of monitoring phosphine with direct reading apparatus to prevent accidents, there is a need for a method of sampling and analysing phosphine to control workers' exposure. The use of filters impregnated with silver nitrate to collect arsine, phosphine and stibine in workplace air has been described in the literature. Having previously chosen this type of filter to collect arsine, we studied its characteristics for phosphine capture. A filter impregnated with sodium carbonate was used both as a prefilter to collect the particles and to trap arsenic trioxide. After dissolving the silver compounds in nitric acid, ICP emission spectrometry was used to carry out the analysis. This article describes the comparative sampling we performed in a microelectronic laboratory and in a fumigation chamber (130 samples) to determine the concentration of AgNO3 impregnation solution to be used, the detection limit of the method and the retention capacity of the impregnated filters. Interference with other gases reacting with silver nitrate was studied and the storage time for sampled filters and analysis solutions was checked. The detection limit of the adopted method is better than 1 microg per filter, and the retention capacity exceeds 300 microg per filter. The problem of how to sample phosphine when H2S, NH3, or HCl is present has been solved, but the problem of sampling phosphine in atmospheres where acetylene evolves remains. Sampled filters and filter solutions are stable for more than three months at ambient temperature.

Environmental Monitoring↗

Peribulbar anaesthesia during keratoplasty: a prospective study of 100 cases.

AIMS: A prospective study was carried out in order to evaluate the efficacy and safety of peribulbar anaesthesia during keratoplasty and to describe surgical conditions. METHODS: Of 137 consecutive keratoplasties, 100 (73%) were performed under peribulbar anaesthesia. Patients received a mean volume of 16.5 (SD 4) ml (range 9-22 ml) of a mixture of etidocaine, bupivacaine, and hyaluronidase. Ocular compression duration was at least 20 minutes and intraocular pressure (IOP) was measured with a Tonopen after injection, compression, and before trephination. Degree of akinesia, pain scoring, complications, and surgical conditions were studied. RESULTS: Before trephination, IOP was 5.73 mm Hg below the preinjection value and was never above 21 mm Hg. Akinesia was complete in 80% of cases and 94% of patients found that surgery was painless. Two patients (2%) were very agitated during surgery. The last patient presented with an acute intraoperative suprachoroidal haemorrhage that did not result in a true expulsive haemorrhage despite an "open sky" situation. Surgical conditions were judged to be optimal by the patients in 92% of cases and by the surgeon in 98% of cases. CONCLUSION: These results demonstrate that peribulbar anaesthesia offers excellent anaesthesia and akinesia during keratoplasty and may be recommended for this type of surgery.

Adolescent↗