PubMed Health⌕ Search

Biomedical subjects

N Rosa

Publications and source records attributed to N Rosa.

At least 19 recordsLinked to original sources

Cardosins: a new and efficient plant enzymatic tool to dissociate neuronal cells for the establishment of cell cultures.

In the present work, we examined the feasibility of using cardosins, plant aspartic-proteinases from Cynara cardunculus L., to isolate cells from rat embryonic brain. Using morphological and functional assays, we compared cell cultures obtained with cardosins with those prepared with a well-established trypsin protocol. Cardosins and trypsin dissociation produced cells with similar yield, viability, and GABA release in response to a depolarizing stimulus. However, cardosins-dissociated cells appeared to recover faster in culture, as assessed by the MTT-test and by the number and length of neurtites, suggesting that cardosins are less aggressive to neurons than trypsin. This feature might be helpful for research and medical purposes requiring fast manipulations of cells.

Animals↗

[Intracorneal invasion of the ciliary body by melanoma].

The authors report a case of a slow reduction of vision in the left eye of a 69-year-old woman. The slit-lamp examination of the eye showed a vascularized achromic subconjunctival mass close to the nasal limbus, invading the inferonasal corneal quadrant. At B-scan and standardized A-scan echography, the mass was shown to be localized to the ciliary body, with characteristics of a malignant melanoma. The patient did not want to undergo conservative treatment. Therefore, enucleation was performed and light microscopy revealed a pigmented malignant melanoma of the ciliary body with extrascleral growth and infiltration of the anterior third of the corneal stroma. No alteration of Bowman's membrane was present. The corneal infiltration, limited to the anterior third of the stroma, could be due to the fact that at this level the collagen fibers are disposed less regularly than those of the posterior two-thirds, with this different disposition responsible for the weak resistance opposed to the tumoral invasion.

Aged↗

Rapid differential diagnosis of Mycoplasma agalactiae and Mycoplasma bovis based on a multiplex-PCR and a PCR-RFLP.

The membrane-protein 81 gene (mb-mp81) of Mycoplasma bovis was cloned, sequenced and compared to membrane-protein 81 gene (ma-mp81) of Mycoplasma agalactiae. After alignment of both sequences, specific primers pairs were designed from variable or unchanging nucleotide segments. In this study, we describe the development and optimization of a multiplex-PCR (MPCR) for the rapid detection of M. agalactiae and M. bovis strains. In addition, a simple and rapid PCR-restriction fragment length polymorphism (RFLP) assay, using the restriction enzymes AluI, DraI, RsaI and XbaI, is described to distinguish between both species. The results suggest that MPCR and PCR-RFLP assays could be used as an alternative method in routine diagnosis for rapid and specific simultaneous detection of M. agalactiae and M. bovis.

Bacterial Proteins↗

Can we utilize photorefractive keratectomy to improve visual acuity in adult amblyopic eyes?

PURPOSE: To report the results of photorefractive keratectomy (PRK) in adult amblyopic patients. DESIGN: Noncomparative case series. PARTICIPANTS: Thirty-eight amblyopic eyes of 36 adult patients who had undergone PRK ranging from -14.63 diopters (D) to +3.75 D (mean, -6.38+/-4.10) were analyzed. METHODS: Preoperative and postoperative (1, 3, and 6 months) refractions and measurements of the best spectacle-corrected visual acuity (BSCVA) were reviewed. Statistical evaluation was performed using a paired Student's t test. MAIN OUTCOME MEASURES: Best-corrected visual acuity before and after PRK. RESULTS: Before PRK, BSCVA ranged between 0.2 and 0.7 lines (mean, 0.60+/-0.13). One month after PRK, BSCVA ranged between 0.2 and 1.2 lines (mean, 0.77+/-0.24), with a significant difference (P = 3x10(-5)). Three months after PRK, BSCVA ranged between 0.15 and 1.15 lines (mean, 0.84+/-0.23), with a significant difference (P = 5x10(-7)). Six months after PRK, BSCVA ranged between 0.25 and 1.3 lines (mean, 0.88+/-0.25), with a significant difference (P = 8x10(-8)). CONCLUSIONS: Our study does not imply that refractive surgery should or may be performed in young children but, rather, that adults wishing to undergo refractive surgery may undertake such procedures despite an amblyopic eye thought to be refractory to visual rehabilitation by conventional methods, such as spectacles and contact lenses.

Adult↗

Goldmann applanation tonometry after myopic photorefractive keratectomy.

PURPOSE: To determine the accuracy of applanation tonometry in patients with corneas thinned by photorefractive keratectomy, and to correlate corneal changes with tonometric readings. METHODS: The intraocular pressure was measured with Goldmann applanation tonometry in 87 patients who underwent photorefractive keratectomy before and 1, 6 and 12 months after treatment. The treatments ranged from -1.5 to -14 diopters (mean=-7.6+/-4.1 diopters) and the fellow eyes were used as controls. RESULTS: In the treated eyes the intraocular pressure before surgery ranged from 11 to 26 mmHg (mean=17.7+/-2.8 mmHg). One month after surgery it ranged from 5 to 22 mmHg (mean=11.9+/-2.7 mmHg) with a significant underestimation (P=1x10(-33)). Six months after surgery it ranged from 6 to 22 mmHg (mean=12+/-3 mmHg) with a significant underestimation (P=5x10(-30)). Twelve months after surgery it ranged from 8 to 22 mmHg (mean=12.7+/-2.7 mmHg) with a significant underestimation (P=5x10(-31)). CONCLUSIONS: A correcting factor should be applied when using applanation tonometry to measure intraocular pressure in patients who have undergone PRK.

Adolescent↗

In vitro evaluation of a new echographic contrast agent.

BACKGROUND: So far, intravenously injected echographic contrast agents have not been able to overcome the lung circle, and their use was confined to the study of right-sided heart abnormalities. A new agent that is able to pass the pulmonary barrier has been manufactured, and it is currently under investigation in ophthalmology. METHODS: A saccharide-based contrast agent (SHU 454) that is not able to overcome the lung filter has been compared in vitro with a new saccharide-based contrast agent (SHU 508 A) that is able to overcome the pulmonary barrier. They have been diluted in saline solution, and the reflectivity of the solution and the eventual sound attenuation have been studied with standardized A scan and a tissue model. RESULTS: The solution with SHU 508 showed a higher reflectivity that lasted longer, without significant sound attenuation. CONCLUSIONS: The long-lasting period of the increased reflectivity will allow to better evaluate the normal and pathological vascular network in the eye and orbit, such as the evaluation of the effectiveness of conservative treatment in cases of malignant melanoma with a spread of the indications of standardized echography to other fields of ophthalmology.

Contrast Media↗

Power doppler ultrasonography in ocular and orbital diseases.

PURPOSE: The authors present a preliminary report to test the usefulness of a new technique called power Doppler ultrasonography (PD) in the study of orbital vessels. MATERIAL AND METHODS: The ophthalmic artery and vein as well as the central retinal artery and vein have been examined in 10 patients with a General Electric Logiq 5000 that allows the examination with both color Doppler ultrasonography (CD) and PD. RESULTS: PD does not alias, is relatively angle independent and is able to better detect the pathways of these vessels. CONCLUSIONS: PD is a new promising technique that may be superior to CD in detecting orbital and ocular vessels.

Blood Flow Velocity↗

The corneal endothelium 12 months after photorefractive keratectomy in high myopia.

PURPOSE: To determine if photorefractive keratectomy with a 193 nm excimer laser could cause human corneal endothelial changes, mainly in high dioptric treatments. METHODS: 18 patients underwent a treatment ranging from 7 to 13 diopters at the corneal apex (mean 10.3 +/- 1.4 SD) with an estimated corneal thinning ranging from 62 to 116 microns (mean 90.7 +/- 12 SD). In these patients a comparison between the number and shape of the corneal endothelial cells has been performed before and 12 months after PRK. RESULTS: The mean cell density was 2818 +/- 337 mm2, before surgery, and 2894 +/- 301 mm2 after 12 months. The polymorphic index was 79.0 +/- 2.3, before surgery, and 81.0 +/- 5.0 after 12 months with no significant changes (p = 0.16 and P = 0.09, respectively). CONCLUSIONS: These results show that photorefractive keratectomy does not cause any significant observable damage to the central corneal endothelium up to 12 months after surgery, even in high myopic treatments.

Adult↗

Use of a special device for the treatment of overfiltration after glaucoma filtering surgery.

BACKGROUND: standardized A and B scan echography were used to look for the possible presence of ciliochoroidal detachment in patients with flat anterior chamber following glaucoma filtering surgery. For this purpose, a scleral shell filled with saline solution was inserted between the lids. As a deepening of the anterior chamber was found in some patients, we planned to utilize these devices for the treatment of flat anterior chambers after glaucoma filtering surgery. METHODS: 16 patients with flat anterior chambers after glaucoma filtering surgery underwent the insertion of a scleral shell filled with saline solution between the lids. The shell was left in place for 15 min. RESULTS: In all of our patients a deepening of the anterior chamber was achieved. In 5 patients 1 application, in 6 patients 2 applications, in 4 patients 3 applications were needed. CONCLUSIONS: The advantages of using this procedures are: the procedure is quick; it does not disturb the corneal epithelium; it is cheap; it does not require suturing the conjunctiva; it can be part of the examination of the anterior segment with echography to look for any ciliary body detachment.

Anterior Chamber↗

Non-contact tonometry in patients that underwent photorefractive keratectomy.

To determine the accuracy of non-contact tonometry in patients with corneas thinned by photorefractive keratectomy, the authors measured the intraocular pressure with a non-contact tonometer and the corneal thickness with an ultrasonic pachymeter in 47 patients before and 9 months after photorefractive keratectomy. The patients were divided into three groups according to the degree of treatment: group I between 1 and 5 diopters (14 eyes), group II between 6 and 10 diopters (18 eyes), group III between 11 and 15 diopters (15 eyes). In the first group of patients mean intraocular pressure was 16.1 (+/-3.85) mm Hg before surgery, and 13.2 (+/-3.14) mm Hg after surgery with a significant difference (p = 0.0027). In the second group of patients mean intraocular pressure was 16.0 (+/-4.13) mm Hg before surgery and 13.0 (+/-3.0) mm Hg after surgery with a significant difference (p = 0.0045). In the third group of patients mean intraocular pressure was 17.7 (+/-3.8) mm Hg before surgery and 12.4 (+/-2.6) mm Hg after surgery, with a significant difference (p = 0.0005). In conclusion, according to our results, non-contact tonometry needs a correcting factor for measuring the intraocular pressure in patients that underwent photorefractive keratectomy, related to the degree of refractive treatment.

Adult↗

Endothelial cells evaluation two years after photorefractive keratectomy.

To evaluate long-term corneal endothelium damages after myopic photorefractive keratectomy (PRK) a morphometric analysis of corneal endothelial cells was performed in 41 patients before and at least 24 months after photorefractive keratectomy. These patients underwent a treatment ranging from -2.5 to -14 dpt with a mean of 8.9 +/- 2.8 dpt at the corneal apex, with an estimated corneal thinning ranging from 23 to 123 microns with a mean of 78 +/- 24.4 microns. Our results showed that the density of endothelial cells ranged from 2,334 to 3,554/mm2 with a mean of 2,819 +/- 351/mm2 before surgery, and from 2,051 to 3,461/mm2 with a mean of 2,774 +/- 330/mm2 after surgery without any significant changes (p = 0.16). The polymorphic index ranged from 58 to 84 with a mean of 77 +/- 5.7 before PRK and from 57 to 89 with mean of 77.7 +/- 7.2 after treatment without any significant changes (p = 0.61). In conclusion, we can state that there is no long-term corneal endothelial damage after PRK even in highly myopic eyes.

Adolescent↗

Refractive outcome and corneal topographic studies after photorefractive keratectomy with different-sized ablation zones.

BACKGROUND: Discrepancies may still occur between planned and actual refractive correction in eyes undergoing photorefractive keratectomy (PRK). The authors have evaluated the use of an enlarged ablation zone. METHOD: A computerized corneal analysis system has been used to compare the changes of the anterior surface of the cornea and the refractive changes before and 1, 6, and 12 months after PRK in 113 patients (119 eyes) treated with an excimer laser. The patients were divided into two groups: those treated with a mask with a 5-mm window (59 eyes), and those with a new mask with different window openings according to the degree of refraction at the corneal apex, starting from 5 mm in diameter for treatments less than 6.5 diopters (D) and from 7 mm in diameter for higher treatments (60 eyes). In the first group, treatment ranged from -2.5 to -16 D (mean +/- standard deviation. -8.5 +/- 3.24 D); in the second group, it ranged from -1 to -14 D (-7.8 +/- 3.06 D). Treatments were evaluated with a chi-square test. RESULTS: In the first group of eyes, 46% were within +/-1 D at 1 month, 37% at 6 months, and 39% at 12 months. In the second group of eyes, 73% were within +/-1 D at 1 month, 60% at 6 months, and 58% at 12 months. The comparison between these data and corneal topographic changes shows that both are more stable and predictable with the new mask compared with the 5-mm mask (P = 0.002, 0.02, 0.04, at 1, 6, and 12 months, respectively). CONCLUSIONS: The use of larger ablation zones improves the predictability and stability of refractive changes.

Adult↗

Macula study with standardized echography.

At an early clinical stage, patients with cystoid macular oedema show no significant changes in their vision. This phase is described as angiographic cystoid macular oedema. Echographic macular studies have in the past years shown that the macular thickness is increased in the early stages of cystoid macular oedema. In these patients there was no evidence of cystoid macular oedema with the visual acuity test, B-scan echography and fluorescein angiography. In this paper an echographic macular study by standardized A-scan echography was performed in 537 patients before extracapsular cataract extraction and intraocular lens implantation in posterior chamber (ciliary sulcus). The results showed that this method is very sensitive in detecting patients with high risk of cystoid macular oedema.

Adult↗

Effects on the corneal endothelium six months following photorefractive keratectomy.

Photorefractive keratectomy (PRK) with a 193-nm excimer laser has been shown not to destroy endothelial cells in vivo. However, this laser could damage endothelial cell metabolism, and result in damage over a longer term. In this paper, a comparison between the number and shape of corneal endothelial cells has been performed in 25 patients before and 6 months after PRK. These patients underwent treatment with myopic correction ranging from 2.5 to 17 dpt and with an estimated corneal thinning ranging from 25 to 170 microns. No significant changes in the number (p = 0.167) and shape (p = 0.075) of endothelial cells have been found. These results show that there are no long-term damages after PRK even in severely myopic eyes.

Adult↗