PubMed Health⌕ Search

Biomedical subjects

N S Thompson

Publications and source records attributed to N S Thompson.

13 recordsLinked to original sources

Effect of a rigid ankle-foot orthosis on hamstring length in children with hemiplegia.

Eighteen children with hemiplegia, mean age 8 years 5 months, underwent gait analysis and musculoskeletal modelling using specially designed software. The maximum lengths of the hamstrings were determined for each child walking in and out of an ankle-foot orthosis (AFO). The muscles were deemed to be short if shorter than the normal average -1SD. In bare feet 8 participants had short medial hamstrings with a higher proportion of these in the less involved individuals. All participants showed an increase in maximum hamstring length when wearing an AFO. In all but one child this was sufficient to restore hamstring length to within normal limits. These finding suggest that hamstring pathology in hemiplegic gait is usually secondary to more distal lower limb pathology.

Ankle Joint↗

Seat-belt syndrome revisited.

This report describes a complex syndrome of injuries occurring in a young female who was a back seat passenger wearing a lap-belt restraint in a high-speed road traffic accident. As a consequence of the forced flexion distraction injury of her lumbar spine, she sustained a fracture-subluxation of the first lumbar vertebra in association with a jejunal perforation and extensive small intestinal mesenteric laceration. She also had a large traumatic hernia of the anterior abdominal wall, which was overlooked at primary laparotomy. This report highlights collectively the classical combination of injuries associated with the lap-belt syndrome and demonstrates the importance of carefully inspecting the anterior abdominal wall for deficiencies, because traumatic herniation may be easily overlooked.

Abdominal Injuries↗

Dia-metaphyseal distal tibial fractures--treatment with a shortened intramedullary nail: a review of 15 cases.

Fifteen patients were reviewed retrospectively with distal tibial fractures treated with a reamed intramedullary nail which had approximately 1 cm removed just distal to the lowermost locking screw. There were 15 patients (nine males and six females). All patients had returned to normal activities of daily living. Eleven patients could perform all leisure activities with no symptoms and three had only minor discomfort, which did not preclude sport. All fractures united, 12 uneventfully and three after a secondary surgical procedure. Three patients had malalignment defined as varus-valgus angulation or recurvatum of 5 degrees or greater. Whilst technically challenging, intramedullary nailing for dia-metaphyseal distal tibial fractures represents a safe and reliable method for managing these injuries. This represents the first report in the English Language literature specifically examining treatment with a shortened tibial nail.

Adult↗

Ongoing coding reviews: ways to ensure quality.

As compliance becomes an increasingly hot topic, how can a facility ensure its coding quality? Here are some ways that HIM departments can improve the quality of coding on a daily basis.

Abstracting and Indexing↗

Supracondylar nail failure: two case reports.

We describe two case reports of supracondylar nail failure in young patients who had sustained high energy, closed, comminuted supracondylar femoral fractures. These injuries had been successfully treated using retrograde intramedullary nails which failed several months later because of excessive activity on the part of the patient without the presence of full flexion at the knee. The failed implants were removed and dynamic condylar screws were inserted with bone graft to the fracture site. This revision procedure produced solid bony union. We recommend that these patients should not fully weight bear, or engage in strenuous physiotherapy after nailing, until the fracture has consolidated and a functional range of knee motion has been obtained. Failed implants should be managed by nail removal, bone grafting and insertion of a dynamic condylar screw.

Accidental Falls↗

Musculoskeletal modelling in determining the effect of botulinum toxin on the hamstrings of patients with crouch gait.

This study aimed to determine the effect of hamstring botulinum toxin A (Btx-A) injection in 10 children with crouch gait in terms of changes in muscle length and lower-limb kinematics. Before Btx-A injection limb kinematics were recorded. Maximum hamstring lengths and excursions were calculated by computer modelling of the lower limb. Data were compared with the averaged hamstring lengths of 10 control children. Hamstrings were defined as short if their length was shorter than the average maximum length minus one standard deviation. Gait analysis was repeated 2 weeks after isolated hamstring Btx-A injection. Pre- and postinjection kinematic data and muscle lengths were then compared. Four of 18 injected limbs in three subjects had short medial hamstring before injection, none of the subjects had short lateral hamstrings. Muscle excursion was significantly reduced in the short and adequate maximum muscle length groups. A significant increase in the semimembranosus and semitendinosus length in all of the injected limbs was noted. Only in the short muscle group was a significant increase in muscle excursion observed. Knee extension improved by 13 degrees in the adequate muscle length group and by 15.6 degrees in the short muscle length group. Pelvic tilt and hip flexion increased in both groups non-significantly. Average walking speed postinjection increased from 0.60 ms(-1) to 0.71 ms(-1). Short hamstrings are over-diagnosed in crouch gait. Hamstring Btx-A injection in patients with crouch gait produces significant, repeatable muscle lengthening and improved ambulatory function.

Botulinum Toxins, Type A↗

Hemicelluloses as structure regulators in the aggregation of native cellulose.

The influence of hemicelluloses on the aggregation of cellulose in higher plant cell walls was modelled by adding hemicelluloses to cultures of the cellulose producer Acetobacter xylinum. Characterization of the celluloses by X-ray diffractometry showed them to be more like those that occur in higher plants; the coaggregation of the hemicelluloses suggests their occlusion within and between the crystalline domains of the celluloses. The authors propose that hemicelluloses may be primary moderators of the tertiary structure of cell wall celluloses, allowing the development of a wide range of properties.

Acetobacter↗

Familiarity and the rarity of deception: two theories and their relevance to play between dogs (Canis familiaris) and humans (Homo sapiens).

One theory of the relation between familiarity and the frequency of deception predicts that familiarity leads to the rarity of deception and another, that familiarity increases deception. We examined which theory applied to play by comparing familiar and unfamiliar partners during play between dogs (Canis familiaris) and humans (Homo sapiens). Deceptions by humans were based on directionality of movement and petting the dog and on the projects show object and throw object, which are specialized for play. Likewise, deceptions by dogs were based on directionality of movement and the project retrieve object (an analogue to show object). Deceptions based on directionality and petting were rare among familiars (and unfamiliars), whereas those based on show object, throw object, and retrieve object were more frequent. The findings suggest that, in play at least, deception may occur frequently.

Adolescent↗

Relevance of the popliteal angle to hamstring length in cerebral palsy crouch gait.

The popliteal angle is a widely used clinical means of assessing hamstring length in cerebral palsy patients. The relevance of the popliteal angle as a measure of hamstring length was assessed in this prospective study. Sixteen patients with cerebral palsy with crouch gait had their conventional and modified popliteal angles measured by nine observers on two separate occasions. With use of the conventional and modified forms of the test, 74 and 70%, respectively, of the observed variability was inter-and intraobserver related. The range of SDs for each observer using the conventional test was 7.1-13.6 degrees (average 10.9 degrees ), and with use of the modified form of the test, the range was 6.3-4.2 degrees (average 10.5 degrees ). The maximum hamstring length of each subject during gait was determined by three-dimensional modelling of their lower limbs. The modified popliteal angle measurements of the most repeatable observer demonstrated an inverse relationship between modified popliteal angle and maximum hamstring length (p < 0.01) and muscle excursion (p < 0.01). Only 10 of 32 limbs had short medial hamstrings.

Adolescent↗

Fractured lateral epicondyle with associated elbow dislocation.

We describe a case series involving a very unusual injury in children, i.e. a Milch 1 fracture of the lateral condyle with an associated dislocation of the elbow. This fracture configuration is normally stable as the intact capitellotrochlear groove serves as a lateral buttress for the coronoid-olecranon ridge of the ulna. In this series, however, each patient had an associated dislocation. These injuries usually present as a clinical dislocation and if the elbow is manipulated before radiographic imaging, the fracture line can be difficult to see on the post-reduction films. We recommend that all patients with a dislocated elbow should have elbow stability assessed under general anaesthesia, because a missed lateral condylar injury can lead to abnormalities in carrying angle, epiphyseolysis or an unstable elbow.

Bone Wires↗