Recombinant tissue-type plasminogen activator therapy in prosthetic mitral valve thrombosis: assessment by transthoracic and transesophageal echocardiography.

Prosthetic cardiac thrombosis is a life-threatening complication that needs prompt diagnosis and therapy. We used recombinant tissue-type plasminogen activator (rT-PA), followed by heparin, in three patients with mitral prosthetic thrombosis, which was evident in two and suspect in one. Transthoracic and transesophageal echocardiography were employed in the diagnosis of both thrombosis and its resolution. No complications occurred. Immediately after the end of treatment with rT-PA, clinical status and echocardiographic data improved in all cases: transthoracic echocardiography showed the normalization of prosthetic function and transesophageal echocardiography showed resolution of thrombosis. One patient needed reoperation for rethrombosis due to the presence of prosthetic fibrous clot. rT-PA, followed by heparin, led to a good clinical result without bleeding and embolic complications in selected patients with mitral prosthetic thrombosis. Transthoracic and transesophageal echocardiography are complementary diagnostic tools in the diagnosis and management of patients with prosthetic thrombosis.

Adult↗

Protection by coenzyme Q10 from myocardial reperfusion injury during coronary artery bypass grafting.

To evaluate the effect of coenzyme Q10 in reducing postoperative cardiac complications after ischemia and reperfusion, we randomly divided 40 patients undergoing elective coronary artery bypass into two groups: patients in group 1 received coenzyme Q10 (150 mg/day) for 7 days before operation, and those in group 2 were the control group. Concentrations of thiobarbituric acid-reactive substances (malondialdehyde), conjugated dienes, and cardiac isoenzymes of creatine kinase were measured in samples from both arterial and coronary sinus sites. Serial sampling was performed 5 minutes after heparin administration, at 10 and 30 minutes during cardiopulmonary bypass, 15 and 30 minutes after aortic cross-clamp removal, and 5 minutes after protamine administration. The concentrations of malondialdehyde, conjugated dienes, and creatine kinase in group 1 were significantly lower than those in group 2. The decrease in plasma malondialdehyde concentrations correlated positively with the decrease in creatine kinase levels in the coronary sinus. The treatment group showed a significantly lower incidence of ventricular arrhythmias during the recovery period than did the control group (p < 0.05). Although the percentage of patients requiring inotropic agents was not significantly different between the two groups, the mean dosage of dopamine required to maintain stable hemodynamics was significantly lower in patients of group 1 than in those of group 2 (p < 0.01). Our findings suggest that pretreatment with coenzyme Q10 may play a protective role during routine bypass grafting by attenuating the degree of peroxidative damage.

Coenzymes↗

Annular abscesses and GRF glue.

Infective endocarditis of the aortic prosthesis is a serious complication of valve surgery. The correction of this condition is difficult and complex procedures are often required. Two patients with aortic bioprosthetic endocarditis complicated with annular abscesses were operated on. The aortic valve was replaced with a bioprosthesis and the annular abscesses were debrided and closed with the aid of gelatin-resorcin-formalin (GRF) glue, which completely sealed the abscess cavities. One year later the patients were asymptomatic and had no clinical or echocardiographic signs of aortic incompetence.

Abscess↗

Bioprosthesis replacement with mechanical valve implantation on the bioprosthetic ring. Surgical and 2D echo considerations.

Removal of a failing bioprosthesis can be a delicate operation and extensive damage can be caused. Eighteen patients with failing bioprostheses underwent excision of the leaflets, then the "new" mechanical valve was sewn onto the "old" bioprosthetic ring. At follow-up, clinical and 2D color-flow echo-Doppler evaluations showed good hemodynamic performance of the mechanical valves.

Adult↗

[Surgical revascularization in acute myocardial infarction].

Surgical treatment of acute myocardial infarction (AMI), while pathogenetically impeccable, has severe limitations in the time factor. Outside of clinical-experimental situations in some pilot-centers, operation for AMI are performed in case of accidents post-PTCA, in patients already hospitalized in cardiology or cardiac-surgery wards, or in case of post-infarction complications. The results in 10 cases of emergency revascularization for AMI after PTCA (2 deaths), 36 cases of AMI treated in hospitalized patients (4 deaths), and 24 septal ruptures (12 deaths) are reported. AMI can be favourably treated surgically, with the aid of modern cardioplegic and reperfusion techniques, if the operation is performed early, and complete revascularization is achieved.

Decision Trees↗

[The usefulness of bioimpedance in patient monitoring in an intensive-therapy heart-surgery unit: a comparison with thermodilution].

Haemodynamic monitoring of intensive care unit (ICU) patients can be carried out by thermodilution system. This method is invasive, does not give a continuous monitoring and complications can occur. Thoracic electrical bioimpedance (TB), a non invasive, fast, easily repeatable method, is able to measure some important haemodynamic parameters: end diastolic volume (EDV), stroke volume, cardiac output (CO), ejection fraction (EF), some contractility indexes, systemic vascular resistances (SVR) and cardiac work. The aim of the present study is to compare CO and SVR obtained by thermodilution with the same indexes obtained by TB. Therefore, 20 ICU patients (12 males and 8 females, mean age 54 +/- 11 years) were studied. Out of them, 16 had been submitted to cardiac surgery in the previous 7 days and 4 were waiting for cardiac surgery. The patients were divided in 2 groups: Group A (N 4) included patients with valvular malfunction and/or cardiac arrhythmias and Group B (N 16) included patients with normal valvular function and sinus rhythm. CO obtained by TB was well related with the one obtained by invasive (INV; r = 0.878; p < 0.001). The mean value of difference of the 2 methods was 12.29 +/- 11.83 for the whole group of 20 patients but it was 26.07 +/- 14.16 in the Group A and 8.84 +/- 8.09 in the Group B confirming the less reliability of the method in patients with abnormal valvular function or in the presence of cardiac arrhythmias. As a consequence, SVR obtained by TB and INV resulted well related (r = 0.752; p < 0.001). The mean value of differences was 11.14 +/- 9.01 in the group of 20 patients and particularly 19.55 +/- 10.87 in the Group A and 9.04 +/- 7.07 in the Group B. In a subgroup of 9 patients, CO was measured at successive times (0, 30, 60, 90 min) by both TB and INV; when comparing the 2 CO values a significant correlation was observed. In conclusion, TB represents a valid method in haemodynamic monitoring of the ICU patients.

Adult↗

Clinical experience with the transvenous Medtronic Pacer Cardioverter Defibrillator (PCD) System.

We review our experience with the transvenous Medtronic Pacer Cardioverter Defibrillator System (Model 7217B), a multifunction implantable pacer defibrillator combined with a transvenous lead system (Transvene). From April 1991 to October 1992, we implanted this device in 19 consecutive patients (11 men and 8 women; average age, 56.5 years). Nine patients (47.4%), 5 with coronary artery disease and 4 with dilated cardiomyopathy, had an ejection fraction of < 30%. The average operative time was 129 minutes. In 18 patients (94.7%), the transvenous lead system provided effective sensing, pacing, and defibrillation during intraoperative testing. In each of these cases, the defibrillation threshold was less than 18 J. In 1 patient (5.3%), it was necessary to switch to epicardial leads, which were implanted through a left thoracotomy. All patients were extubated in the recovery room. The average hospital stay was 8 days. There was no early mortality or morbidity. During a maximum follow-up period of 17 months (mean, 9.2 months), no sudden death occurred. The implantable system terminated 245 ventricular tachycardia episodes in 14 patients (73.7%) and 82 ventricular fibrillation episodes in 13 patients (68.4%). Two hundred eleven (86.1%) of the ventricular tachycardia episodes were resolved by antitachycardia pacing alone. In 2 patients (10.5%), the caval electrode became dislocated; repositioning of the electrode was followed by repeat defibrillation threshold evaluation. Our experience shows that the transvenous Medtronic Pacer Cardioverter Defibrillator System provides safe, effective treatment of ventricular tachyarrhythmias. Because the perioperative mortality and morbidity are extremely low, use of this device may be particularly beneficial in patients with a high operative risk. Moreover, the lower number of unpleasant therapeutic shocks should increase patient a acceptance of the device.

Adult↗

[Use of enoximone in the postoperative course of heart surgery].

The aim of this study was to evaluate the efficacy and safety of enoximone, an imidazolonic compound inhibiting cardiac phosphodiesterase III, during the postoperative period. The drug was administered prior to the usual stages of weaning the patient off extracorporeal circulation, to a group of 20 subjects who presented an ejection fraction of less than 35% following hemodynamic studies. Patients were randomly subdivided into 4 groups each of which received a different dose of enoximone according to the following protocol: Group A, 1 mg/kg bolus and slow infusion at 10 gamma/kg/min; Group B, 0.5 mg/kg bolus and slow infusion at 15 gamma/kg/min; Group C, 0.5 mg/kg bolus and slow infusion at 10 gamma/kg/min; Group D, slow infusion at 10 gamma/kg/min. The best results in hemodynamic terms and with regard to the positive inotropic and vasodilatory action of the drug in question were obtained in Group C. Increased cardiac output was observed in all patients within 120 minutes of enoximone administration and reduced systemic vascular resistance after approximately 6 hours of infusion. Special attention should be drawn to the use of the drug in patients who do not respond to conventional therapy due to its mechanism of action which is not dependent on beta receptors, thus enabling good results to be achieved even when these are down regulated. Special care must be taken however in administrating enoximone to platelet-deficient patients since the reduction of platelet levels is one of its collateral effect. Other collateral effects observed were: supraventricular arrhythmias and ventricular tachyarrhythmias.

Cardiac Output↗

Low dose aprotinin as blood saver in open heart surgery.

Bleeding after open heart surgery is still a great concern for the surgeon, especially when the surgical field has been revised accurately and hemostatic stitches and electrical cauterization have been used extensively. Among non-surgical adjuncts, aprotinin has been reported as very effective in reducing complications. At the time we started using this drug, we intended to test two different dosages lower than those reported in the literature. We evaluated three groups of 18 patients: the first (A) received about 350 mg of aprotinin from the start of anesthesia up to the end of operation (140 mg in the priming of cardio-pulmonary bypass and 70 mg/h i.v. during the procedure; the second (A/2) received half that dose (i.e. 70 mg and 35 mg, respectively), and the third (C) did not receive aprotinin. We compared in these groups: postoperative bleeding, blood transfusions, red blood cells, hemoglobin, hematocrit, platelets. The results were good only in the A group: bleeding was reduced and few transfusions were required. The patients in the A/2 and C groups did not show significant differences. From our observations we conclude that aprotinin is a useful adjunct, but has to be given in the proper dose.

Aprotinin↗

Myocardial revascularization in women.

To compare the results of coronary artery bypass in women and men, we reviewed our experience from January 1976 through June 1989. During this period, 170 women with coronary artery disease but with no other cardiac abnormalities underwent coronary artery bypass. We compared this group with a group of 150 men, matching them according to age, presence of angina, extent of disease, and surgical treatment. Preoperative clinical features, surgical data, and early and late results were analyzed. The operative mortality was similar between groups (2.9% for women vs 2.6% for men). The women, however, were more frequently overweight (54% vs 15%; p <0.001) and more often had the following: diabetes mellitus (34% vs 20%; p <0.01), a coronary artery diameter of <1.8 mm (64% vs 29%; p <0.001), poor saphenous vein quality (50% vs 16%; p <0.001), and incomplete revascularization (20% vs 4%; p <0.001). After a mean follow-up of 6 years, the women also had a higher incidence of recent-onset myocardial infarction (31% vs 12%; p <0.001) and a greater tendency to be symptomatic (48% vs 19%; p <0.001). The 12-year cumulative survival rates were similar in both groups (76.2% for women vs 77.1% for men). According to logistic regression analysis of the significantly different variables, the only independent determinants of postoperative asymptomatic status were satisfactory coronary artery caliber, good saphenous vein quality, and complete revascularization. We conclude that poorer functional results after coronary artery bypass surgery in women may be caused by a poorer quality of revascularization, which in turn is a result of smaller coronary artery diameter, worse distal runoff, and less satisfactory vein quality.

Journal Article↗

Double valve Implantation. Long-term evaluation of 8 different bioprostheses.

From January 1976 through December 1987, 194 patients with a mean age of 43.3 +/- 13.7 years (range, 11 to 74 years) underwent double (mitral and aortic) replacement of native valves with 8 types of bioprostheses: Carpentier-Edwards, 127 valves; Hancock, 76 valves; Liotta-Bioimplant, 57 valves; Ionescu-Shiley, 53 valves; Vascor, 27 valves; Carpentier-Edwards Pericardial, 22 valves; Angell-Shiley, 20 valves; and Implamedic, 6 valves. Concomitant cardiac procedures were performed in 25 patients (12.8%). There were 18 operative deaths (9.27%). Our retrospective analysis was restricted to 352 bioprostheses implanted in the 176 patients who survived surgery and were considered at risk for valve tissue failure. The overall cumulative duration of follow-up was 1,174.1 patient-years (range, 1 to 13 years). The durations of follow-up for specific valves were: Carpentier-Edwards, 920.2 valve-years; Hancock, 383.8 valve-years; Liotta-Bioimplant, 310.2 valve-years; Ionescu-Shiley, 357.7 valve-years; Vascor, 131.2 valve-years; Carpentier-Edwards Pericardial, 52.0 valve-years; Angell-Shiley, 167.0 valve-years; and Implamedic, 31.0 valve-years. Thirty patients had thromboembolic accidents, for a linearized incidence of 2.5% per patient-year. At 13 years, the actuarial freedom from thromboembolic accidents was 85.8% +/- 10.7%. Nine patients had endocarditis, for a linearized incidence of 0.7% per patient-year. At 13 years, the actuarial freedom from endocarditis was 92.0% +/- 1.5%. Twenty-four patients had valve tissue failure, for a cumulative linearized incidence of 1.87% per valve-year. The cumulative actuarial probability of freedom from valve tissue failure was 78.6% +/- 3.7% at 10 years and 51.2% +/- 10.7% at 13 years. The 24 patients with valve tissue failure all underwent reoperation: 20 of these had double valve replacement, 3 had aortic valve replacement alone, and 1 had mitral valve replacement alone. The mean interval between initial valve implantation and reoperation was 66.9 +/- 28.8 months. At reoperation, the hospital mortality was 15.1% (5 patients). This study showed that the long-term results of valve implantation are not significantly influenced by either prosthesis design or material. Moreover, the incidence of degenerative change was similar in the aortic and mitral positions.

Journal Article↗

Abnormalities in serum lipoprotein composition in patients with premature coronary heart disease compared to serum lipid matched controls.

Serum lipoprotein composition was examined in 18 male patients (mean age 44 +/- 0.9 years) who had undergone coronary artery by-pass surgery because of premature coronary heart disease (PCHD) and in 18 control subjects, matched with patients for sex, age, body mass index and serum cholesterol and triglyceride. Cholesterol, triglyceride and apolipoprotein B (apo B) concentrations in very low density lipoprotein (VLDL) and in low density lipoprotein (LDL) did not differ in the two groups, but high density lipoprotein (HDL)-cholesterol was significantly lower in PCHD patients (P less than 0.02). Cholesterol/apo B, triglyceride/apo B and phospholipid/apo B ratios in VLDL were significantly higher in patients than in controls (P less than 0.05, P less than 0.01 and P less than 0.001, respectively). The relative VLDL enrichment in cholesterol was mainly due to the non-esterified moiety (P less than 0.01). These VLDL abnormalities as well as the low HDL-cholesterol suggest an impairment of VLDL catabolism in PCHD patients.

Adult↗