The assessment of intramural stress alignment on the beating heart in situ using micro-ergometry: functional implications.

The main local stress transmission pathways in the left ventricular base, midportion and apex in up to seven layers have been assessed in normal dog and porcine hearts, in hypertrophied dog hearts, and in three pig hearts having undergone a temporary left ventricular outflow stricture. The rotational sensitivity of needle force probes was used to determine the focal surface-parallel direction of the myocardial tension vector. In all places investigated the orientation of the force transmission pathways differs slightly from the morphologically determined fibre alignment. Vector rotation upon an axis normal to the epicardial surface is definitely tempered as compared to fibre rotation. Alterations in the force transmission pathways assessed in hypertrophied dog hearts by micro-ergometry qualitatively confirm structural remodelling in so far as an irregularity in the transmural rotation of the main stress vector was found. The measured disparities between the alignment of the myocardial fibre weave and the direction of stress transmission both in the normal and the diseased heart is widely individual, and hence, scattering of the data is marked. However, it must also be called into consideration that the measured orientation of force vectors is that at the moment of highest developed force, only. Further investigations will elucidate if discrepancies between that force vector and morphology are less pronounced when the vector is averaged over the entire heart cycle.

Animals↗

Inhomogeneities in wall stress measured by microergometry in the heart muscle in situ.

Microergometry is a method which we have developed as a tool to measure local mesh-tension within the myocardial weave at any measuring site of both ventricles and the septum on the beating heart in situ. In a mapping procedure on pig and dog hearts, both in control conditions and in the hypertrophied state after aortic banding, local mesh-tension was measured in several areas and in up to eight depths proceeding from the epicardium to the endocardium: Probe-to-fibre coupling is definitely more stable in the canine myocardium than in the porcine heart muscle, probably due to a more effective connective tissue fettering of the canine myocardial weave. The observed longitudinal gradient, with the highest tension in the base, of control dog hearts was levelled out in the hypertrophied hearts. Furthermore, in control dog hearts mesh-tension in the subepi- and subendocardial layers was higher than in the midlayers. This pronounced midlayerhypotension was smoothed in the hypertrophied hearts. Further studies will be dedicated to the question of whether the impact of ventricular size and shape on intersegmental stress transmission is determined by the Frank-Starling mechanism alone or whether protracted remodelling processes on the level of the local fibre weave cause slow coupling alterations.

Animals↗

High-frequency oscillation in an adult porcine model.

OBJECTIVE: Controversy exists as to whether high-frequency oscillatory ventilation can be used on babies and small laboratory animals only, or whether high-frequency oscillatory ventilation can also be efficient in the adult patient and large (> 65 kg body weight) laboratory animals. Moreover, controversy exists as to whether limitations in high-frequency oscillation efficiency are caused by the size and shape of the bronchial system, by the lack of low impedant intersegmental gas flow in lung parenchyma, or by inappropriate high-frequency ventilators and ancillary hardware. Therefore, our objective in this study using the adult pig as a model of the adult patient was to test whether the adult airway system is suited to the use of high-frequency oscillatory ventilation or whether there are geometrical, structural, or functional limitations to efficient ventilation by high-frequency oscillation. DESIGN: Prospective, controlled, randomized comparison over 8 to 16 hrs of ventilatory management. SETTING: Experimental thoracovascular surgery laboratory in a university hospital. SUBJECTS: Fifteen adult, female, house swine (weight 90 to 140 kg). INTERVENTIONS: We evaluated the ventilatory effect of a wide range of oscillation frequencies (10-15 to 35-45 Hz), tidal volumes (0.5 to 2.2 mL/kg), and bias flow volumes (10 to 70 L/min) at a mean airway pressure of 12 +/- 1 cm H2O in anesthetized and relaxed pigs who did not have lung injury. MEASUREMENTS AND MAIN RESULTS: Arterial blood gases are mainly dependent on tidal volume, frequency, and mean airway pressure. A threshold bias flow volume of 35 +/- 5 L/min is required to prevent CO2 rebreathing. In the group of lightweight animals (65 to 99 kg), the most efficient frequency band for CO2 elimination was approximately 25 Hz. The most efficient frequency band for arterial oxygenation was found to vary between individuals more than the most efficient frequency band for CO2 elimination. In the group of heavy animals (100 to 140 kg), no most efficient mean frequency could be assessed, probably because the excitation system was limited. We confirmed that tidal volume on its own had an effect on CO2 elimination ("tidal-volume effect"), although CO2 elimination was mainly determined by the product of tidal volume and oscillation frequency (oscillated minute volume), at least up to a critical frequency. Beyond that frequency, CO2 elimination could not be enhanced. The most efficient mean airway pressure in unimpaired lungs was assessed at 12 +/- 1 cm H2O. CONCLUSIONS: Adult pigs with a body weight in the range of the weight of clinical adult patients can be ventilated by high-frequency oscillation at tidal volumes smaller than, equal to, or slightly more than anatomical deadspace. The most efficient frequency for gas exchange varied between individuals. Tidal volume had an enhancing effect on CO2 elimination. The frequency dependency of PaO2 may have been related to a frequency-dependent structural remodeling of the airway system, which occurred even though the mean airway pressure was kept constant. These results demonstrate that failure of adequate ventilation by high-frequency oscillation is caused by a) CO2 rebreathing, b) the avoidance of an appropriate alveolar recruitment strategy, and c) an underpowered, high-frequency ventilatory system (oscillator) that is unable to deliver appropriate pressure oscillations. These limitations led to insufficient CO2 elimination and/or inadequate arterial oxygenation.

Animals↗

[High-frequency artificial respiration. II. Intratracheal high-frequency pressure changes with a rotation-valve catheter].

From the history of ventilatory support, the early studies of Auer und Meltzer only now seem to find a functional explanation. A rotating valve mounted on the tip of an endotracheal tube delivers a widespread gas bolus. The turbulent flow acts as a stirring device on the intrapulmonary gas volume. The method reduces the directional selectivity that typically limits the efficiency of jet ventilation. Systematically changing the rotational frequency between 10 and 80 Hz allows sequential stimulation, compartment by compartment, of the entire lung, which also gives rise to frequency-dependent local air-trapping that sequentially inflates different compartments. Jet ventilation and high-frequency oscillation were compared in dogs with the rotating valve tube by taking blood gas samples from 4-6 intrapulmonary veins: jet ventilation is characterized by preponderant ventilation of lung compartments opposite the lower aperture of the endotracheal tube. High-frequency oscillation induces a frequency dependent repartition of alveolar ventilation. The rotating valve tube definitely contributes to the homogenisation of alveolar ventilation in a manner that is less dependant upon segmental compliance than conventional ventilation.

Animals↗

Local myocardial and global ventricular function compared during positive inotropic medication.

The assessment of the pharmacological efficiency of cardiotonic drugs interferes with the complex force generation within the spatially netted myocardial meshwork. By multifocal local force and distance measurements we distinguished "afterloaded" from "unloading" force types, which essentially differ in their transient behaviour during changes in ventricular shape. Histologically we found the "afterloaded" force type in oblique fibre populations whereas the "unloading" force curve is generated in surface parallel fibres. Amrinon reduces pre- and afterload, thus inducing ventricular shrinkage. The resulting rearrangement of the intramural force pattern modifies the transmission of fibre tension to ventricular ejection in a way that contractility indices, derived from left ventricular pressure, become inapplicable. However, direct intracoronary drug injection, monitored by segmental force and distance measurements within the irrigated myocardial area, characterizes Amrinon as a potent positive inotropic drug.

Amrinone↗

Coronary rheothermia: a quasi non-invasive method for controlling bypass patency.

A method based on the principle of thermodilution was developed for a quasi non-invasive permeability control of aortocoronary bypass. An epivascularly-attached thermistor records the cooling of the bypass wall when, following the intravenous injection of 5 to 10 ml of a NaCl solution at 4 degrees C, a bolus of cooled blood passes through the bypass. During cardiosurgical intervention, the thermistor is attached to the venous bridge by one or 2 sutures. The efferent cable goes through the thorax wall and is coupled to a subcutaneously implanted telemetric amplifier unit. The influence of the vessel wall on the perivascular temperature signal, as compared to the intravascular one, was studied in acute and chronic animal experiments. In acute experiments the perivascular peak of temperature was found to be lower than the intravascular one. Continuous measurements over 9 days showed variations in the perivascular signals which must have been due to changes in the thermal capacity of the tissue coupled to the thermistor as well as to changes in resistance caused by a variable extent of scarred area and by the varying water content of the wound bed. These variables will continue to keep rheothermia within the limitations of a method with primarily binary results (= bypass: open or closed). Given stable coupling conditions after full development of the scar around the thermistor, the signal falsification by the then constantly coupled tissue capacity becomes calculable such as to obtain semiquantitative results which, theoretically should vary predominantly with cardiac output.

Animals↗

[Catheter tip force probe: a paraclinical development for per- and postoperative monitoring in heart surgery].

Local intramyocardial "one-point" force measurement is well adapted to the myocardial architecture. The dense three-dimensional muscle network does not permit direct measurement of longitudinal tension in a particular bundle of muscle fibers. However, measurements on the skeletal muscle have shown changes in tendon stress to be strictly proportional to changes in local force measured simultaneously at different sites on the gastrocnemial muscle. In the heart in situ the response to inotropic and pre- and afterloads changes is extremely sensitive. However, in comparison to left ventricular pressure, local force measurements at different sites and in different ventricular layers show distinct force gradients and phase dislocation, indicating a wide range of inhomogeneities in ventricular dynamics. The method is suitable for clinical application in cardiac surgery: the probe may be implanted directly on the exposed heart or during ventricular catheterization using a pointed catheter tip force probe.

Cardiac Catheterization↗