PubMed Health⌕ Search

Biomedical subjects

N Toyooka

Publications and source records attributed to N Toyooka.

7 recordsLinked to original sources

[Synthesis and its application to the synthesis of biologically active natural products of new and versatile chiral building blocks].

This article describes a design and synthesis of new and versatile chiral building blocks and its application to the biologically active natural product synthesis. The chiral building blocks were prepared using a biocatalysis in an enantiomerically pure state. As an application of the above chiral building blocks to the synthesis of biologically active natural product, we demonstrated the diastereodivergent synthesis of the 3-piperidinol alkaloids cassine, spectaline, prosafrinine, iso-6-cassine, prosophylline, prosopinine, and also established the flexible route to the 5,8-disubstituted indolizidine or 1,4-disubstituted quinolizidine type of Dendrobates alkaloids. As another application to the synthesis of biologically active alkaloids, we accomplished the first enantioselective total synthesis of marine alkaloids clavepictines A, B, and pictamine using a highly stereoselective Michael type quinolizidine ring closure reaction as the crucial step, and the first total synthesis of a marine alkaloid lepadin B was also achieved using aldol cyclization controlled by a A strain.

Alkaloids↗

Detection of muscle layer invasion with submillimeter pixel MR images: staging of bladder carcinoma.

Conventional magnetic resonance (MR) images used for the pelvic organs generally have a pixel size of 1.3 mm x 1.3 mm. We obtained images with a higher resolution than conventional images, and evaluated the usefulness of this type of image in staging urinary bladder carcinoma. Twenty-six patients having either transurethral resection of bladder tumor (TUR-BT) or cystectomy were retrospectively studied. T2-weighted images of the bladder were acquired with a 20 cm field-of-view, a matrix size of 224 x 224 (pixel size: 0.9 mm x 0.9 mm), and a slice thickness of 7 mm using a 0.5 T system. MR appearances of the carcinoma were divided into the following five categories: no abnormality found on the inner surface of the bladder wall (0), high signal layer or protrusion without breakage of the wall (I), partial disruption of the wall (II), transmural disruption of the wall (III), and complete disruption with mass formations in the perivesicular region (IV). These findings were correlated with the TNM pathologic staging determined from each tissue specimen. A prediction for muscle layer invasion was calculated by selecting pathologic stage pT2 and MR category III as a boundary measure. The accuracy was 96.2%, the sensitivity 100.0%, and the specificity 91.7%. The results obtained indicate that submillimeter pixel MR imaging shows promise as a noninvasive method for the preoperative staging of bladder cancers.

Aged↗

A wireless axial pair resonator.

A wireless axial pair resonator consists of two coils coupling inductively with a body coil, which is used as a signal transmitter and receiver. Computer simulations gave signal enhancements of 1.41 and 1.47 for the resonators of 15- and 20-cm diameter, whereas those of phantom studies gave 1.37 and 1.49.

Computer Simulation↗

Magnetic resonance images of hematospermia.

Seminal vesicles and their adjacent structures were studied using magnetic resonance imaging (MRI) in 7 normal volunteers and 15 patients with hematospermia. Normal seminal vesicles are depicted on T2-weighted images either as a mixture of high- and low-signal granules or as a convolution of tubules with a diameter of less than 0.5 cm. Fourteen of the 15 patients with hematospermia exhibited abnormalities on MRI. Dilatation or cyst formation in the seminal vesicle was observed in 13 patients, and a dilatation of the midline structure was seen in 3 patients. Abnormal signal intensity of the seminal vesicles was seen in 11 patients and was thought to be due to subacute hemorrhage.

Adult↗

Submillimeter-pixel MR images of hepatic cavernous hemangiomas.

Several criteria have been used for differentiating hepatic cavernous hemangioma from other tumors at magnetic resonance imaging (MRI). Included are signal intensity and lobulation of the tumor. We counted the frequency of presence of lobulation of liver hemangiomas on T2-weighted images (T2WI), and measured the signal-intensity ratio (SIR) on T1-weighted images (T1WI) and on T2WI with a 0.9 mm x 0.9 mm pixel size using a 0.5 T magnetic resonance system. Eighty-three cavernous hemangiomas in 44 patients and 67 malignant tumors in 44 patients were retrospectively studied. Seventy-five of the cavernous hemangiomas (90%) exhibited lobules of various sizes, and four of the malignant tumors (6%) exhibited lobulations. The cavernous hemangiomas had a significantly higher SIR than the malignant tumors on T2WI: 3.0 +/- 0.7 and 1.9 +/- 0.8 (p < 0.001), respectively. The presence of lobulation together with a high SIR was a useful measure for differentiating cavernous hemangiomas from other liver tumors.

Adult↗