Fleck dystrophy of the cornea; a report of cases from three generations of a family.

Fleck dystrophy of the cornea is characterized by numerous, tiny, small opacities scattered throughout the entire corneal stroma. The mode of inheritance is autosomal dominant, and this dystrophy is considered to be bilaterally symmetric. This report describes five members from three-generations of the same family with corneal fleck dystrophy. Their clinical features and genetic inheritance pattern are discussed. Visual acuity in all patients was normal and the density of opacities were similar except for two patients with less density. Except for one who presented with mild photophobia all patients were asymptomatic. The inheritance pattern appeared as autosomal dominant with variable expression.

Adolescent↗

Calculation of intraocular lens power with the SRK II formula for axial high myopia.

AIM: The SRK II formula has been widely used for intraocular lens (IOL) power calculations. The predictability of this formula is evaluated in axial myopic patients. METHODS: Planned extracapsular cataract extraction and posterior chamber IOL implantation (PECCE + IOL) were performed on 98 eyes of 98 patients with axial length > 24.5 mm. Cases had no preoperative complications and postoperative visual acuity was at least 0.5 (Snellen). Corneal refractive power and axial length were measured preoperatively and emmetropic IOL power calculations were made using the SRK II formula. Long-term (mean 4.7 months) visual acuities and refractions were noted postoperatively. RESULTS: The absolute refractive error was < 1.00 Diopters (D) in 57 eyes (58.2%) and < 2.00 D in 83 eyes (84.7%). The mean absolute error of the SRK II formula in axial myopia was 1.16 D +/- 0.78 SD. CONCLUSIONS: The SRK II formula is not very accurate in axial myopic patients.

Biometry↗

Amalgam repair: evaluation of bond strength and microleakage.

This study evaluated the tensile bond strength of "repaired" amalgams and compared the degree of microleakage. Amalgam (Cavex avalloy) was condensed into plastic tubes (3 mm in diameter, 10 mm in height) to the half-length. After storage in water at 37 degrees C for two days, the remaining parts of tubes were filled with amalgam (A), cavity varnish (CV)+A, Liner Bond 2V (LB2V)+A, 3M Opal Luting Cement (3MOLC)+A, Panavia F(PF)+A, Metabond(MB)+A, Fuji BondLC(FB)+A, HytacOSB(HOSB)+Hytac Aplitip (H), Liner Bond2V+Clearfil AP-X(CAP). The bond strengths for 15 samples of each restoration group were determined. For the microleakage study, MOD cavities of 90 extracted human premolars were used. The distal half of cavities were filled with amalgam. After storage in water at 37 degrees C for two days, the mesial half of the cavities were filled to simulate a clinical repair. The "repair" was placed using the procedures applied in the bond strength study. The teeth were stained with basic fuchsine (0.5%), sectioned and evaluated for dye penetration. In both parts of study, the data were analyzed by ANOVA and Duncan's multiple range tests. Bond strength values (MPa) were: A+PF+A 3.84+/-1.08, A+LB2V+A 3.15+/-0.97, A+LB2V+CAP 3.05+/-0.53, A+MB+A 2.86+/-0.88, A+HOSB+H 2.58+/-0.51, A+3MOLC+A 2.11+/-0.75, A+FB+A 0.68+/-0.59. The repaired A+A and A+CV+A groups were separated before testing. The A+PF+A group showed the highest bond strength (p<0.05). Microleakage in the cervical margins of repaired restorations was lower in the amalgam groups than microleakage in the resin composite and compomer groups. PF, MB, 3MOLC and FB performed better at the amalgam "repair" interface. The A+LB2V+A group showed no microleakage at both the occlusal and gingival test regions.

Analysis of Variance↗