PubMed Health⌕ Search

Biomedical subjects

N V Lavrik

Publications and source records attributed to N V Lavrik.

5 recordsLinked to original sources

Enantioselective sensors based on antibody-mediated nanomechanics.

The use of microfabricated cantilevers as bioaffinity sensors was investigated. Since many bioaffinity interactions involve proteins as receptors, we conducted studies of the magnitude, kinetics, and reversibility of surface stresses caused when common proteins interact with microcantilevers (MCs) with nanostructured (roughened) gold surfaces on one side. Exposure of nanostructured, unfunctionalized MCs to the proteins immunoglobulin G and bovine serum albumin (BSA) resulted in reversible large tensile stresses, whereas MCs with smooth gold surfaces on one side produced reversible responses that were considerably smaller and compressive. The response magnitude for nanostructured MCs exposed to BSA is shown to be concentration dependent, and linear calibration over the range of 1-200 mg/L is demonstrated. Stable, reusable protein bioaffinity phases based on unique enantioselective antibodies are created by covalently linking monoclonal antibodies to nanostructured MC surfaces. The direct (label-free) stereoselective detection of trace amounts of an important class of chiral analytes, the alpha-amino acids, was achieved based on immunomechanical responses involving nanoscale bending of the cantilever. The temporal response of the cantilever (delta deflection/delta time) is linearly proportional to the analyte concentration and allows the quantitative determination of enantiomeric purity up to an enantiomeric excess of 99.8%. To our knowledge, this is the first demonstration of chiral discrimination using highly scalable microelectromechanical systems.

Amino Acids↗

An approach to conductometric immunosensor based on phthalocyanine thin film.

A new approach to conductometric biosensors utilizing iodine-sensitive phthalocyanine thin films has been proposed. The excellent sensitivity of the tetra-tert-butyl copper phthalocyanine (ttb-CuPc) to free iodine was used for the first time to detect a peroxidase-initiated reaction in an aqueous medium. To minimize the interfering effect of aqueous electrolytes on the impedance responses of the ttb-CuPc film itself, Au/Cr interdigitated planar electrodes bearing ttb-CuPc thin films were protected with hydrophobic gas-permeable membranes, namely thermally evaporated calixarene or plasma polymerized hexamethyldisiloxane films. Impedance spectroscopy data were analyzed in order to define the optimal operating frequency. An enzyme sensor with peroxidase immobilized in a cross-linked albumin matrix was tested. Its impedance responses were studied under variation of the substrate concentration, pH, ionic strength and buffer capacity. These results were used to define conditions for peroxidase-linked immunoassay in subsequent tests. With the developed sensor, concentrations of IgG in 0.2-2 micrograms/ml range were measured in a competitive mode with satisfactory accuracy. The detection of IgG in both test solutions and blood serum samples has been demonstrated.

Biosensing Techniques↗

Enhancing chemi-mechanical transduction in microcantilever chemical sensing by surface modification.

The use of chemically selective thin-film coatings has been shown to enhance both the chemical selectivity and sensitivity of microcantilever (MC) chemical sensors. As an analyte absorbs into the coating, the coating can swell or contract causing an in-plane stress at the associated MC surface. However, much of the stress upon absorption of an analyte may be lost through slippage of the chemical coatings on the MC surface, or through relaxation of the coating in a manner that minimizes stress to the cantilever. Structural modification of MC chemical sensors can improve the stress transduction between the chemical coating and the MC. Surfaces of silicon MC were modified with focused ion beam milling. Sub-micron channels were milled across the width of the MC. Responses of the nanostructured, coated MCs to 2,3-dihydroxynaphthalene and a series of volatile organic compounds (VOCs) were compared to smooth, coated MCs. The analytical figures of merit for the nanostructured, coated MCs in the sensing of VOCs were found to be better than the unstructured MCs. A comparison is made with a previously reported method of creating disordered nanostructured MC surfaces.

Journal Article↗

IR imaging using uncooled microcantilever detectors.

Uncooled bimaterial microcantilever detectors were fabricated and used to obtain infrared (IR) images of objects at temperatures ranging from room temperature to a few hundred degrees C. Images were obtained using both single 50 micro m x 50 micro m microcantilever IR detectors and arrays of microcantilever detectors. Thermal radiation from the target object was imaged onto the detector and the resulting temperature change caused microcantilever bending due to the bimaterial effect. This micromechanical bending was measured using two different non-contact optical readout techniques and IR images were obtained. A smaller size (20 micro m x 20 micro m) microcantilever IR detector was also used to capture IR images of near room temperature objects.

Journal Article↗

Detection and differentiation of biological species using microcalorimetric spectroscopy.

We report on the application of infrared (IR) microcalorimetric spectroscopy ( micro -CalSpec) to the identification and detection of trace amounts of biological species. Our approach combines principles of photothermal IR spectroscopy with ultrasensitive microcantilever (MC) thermal detectors. We have obtained photothermal IR spectra for DNA and RNA bases and for Bacillus Cereus (an anthrax simulant) in the wavelength range of 2.5-14.5 micro m (4000-690 cm(-1)). The measurements are accomplished by absorbing biological materials directly on a MC thermal detector. The main advantage of the developed micro -CalSpec is its unprecedented sensitivity as compared to any of the previously explored IR techniques, including FTIR and photothermal FTIR methods. Our results demonstrate that <10(-9)g of a biological sample is sufficient to obtain its characteristic micro -CalSpec spectrum that contains information-rich chemical (vibrational) signatures. This opens up a new opportunity to create inexpensive high-throughput analytical systems for biochemical detection.

Anthrax↗