Biological activity of tri-calciumphosphate/hydroxyl-apatite granules mixed with impacted morsellized bone graft. A study in rabbits.

Reconstruction of bone defects with impacted morsellized cancellous bone grafts (MCB) is a popular method. Because of a shortage of human bone, mixing with biomaterials may be attractive. Ceramics may be used as bone graft extenders. In this study, various volume mixtures of biphasic tri-calciumphosphate/hydroxyl-apatite (TCP-HA) granules (1.5-2 mm) with MCB were examined in a non-loaded defect model in rabbits. Direct post-operatively, many 10-150 microm TCP-HA particles were present due to impaction. Irrespective to the group, after 8 weeks, virtually all MCB was resorbed and most TCP-HA granules were osseous-integrated with newly formed bone. The cross-sectional areas of TCP-HA after 8 weeks was generally smaller compared with direct post-operatively and the number of small 10-150 microm TCP-HA particles seemed reduced. Macrophages and giant cells were sparse after 8 weeks. In conclusion, the osteoconductivity of various mixtures of MCB and TCP-HA granules is not dependent on the ratio of TCP-HA over MCB. The reduced number of the 10-150microm TCP-HA particles after 8 weeks, may suggest that a cellular mediated resorption process of TCP-HA granules took place. Based on these favorable biological findings subsequent in-vivo experiments are warranted in load-bearing conditions to investigate whether these findings hold for joint reconstruction purposes.

Animals↗

Functional evaluation of the TKA patient using the coordination and variability of rising.

A kinematic analysis of the knee function is important for the evaluation of total knee arthroplasties (TKA). We used the coordination and variability of rising from a chair as functional knee parameters. Twelve knee patients were measured prior to surgery (=pre-TKA group) and one year after surgery (=post-TKA group). A group of 15 healthy, age-matched subjects was selected as control group. The WOMAC questionnaire, frequently used by orthopaedic surgeons, was administered prior to the test. The test consisted of 10 times rising from a low chair and 10 times from a high chair. Knee and hip angles and angular velocities were measured with electrogoniometers. The relative phase (=MRP) between hip and knee was a measure for the coordination of rising and the standard deviation of the relative phase of the 10 trials (=SRP) was a measure for the variability. The coordination and variability of rising of the TKA patients were compared to the control group, and the relationship with the WOMAC questionnaire was calculated. The coordination of rising from a high chair and the variability of rising from both chair heights were significantly different for the pre-TKA group compared to the control group (p<0.05). The post-TKA group showed no significant differences with the control group, which indicates a functional recovery after TKA implantation. The functional parameters correlated adequately with the subjective WOMAC questionnaire. This study showed that our method is an objective measure of functionality and it will be worthwhile to use it as an additional evaluation tool.

Aged↗

The stability of the femoral component of a minimal invasive total hip replacement system.

In this study, the initial stability of the femoral component of a minimal invasive total hip replacement was biomechanically evaluated during simulated normal walking and chair rising. A 20 mm diameter canal was created in the femoral necks of five fresh frozen human cadaver bones and the femoral heads were resected at the smallest cross-sectional area of the neck. The relatively short, polished, taper-shaped prostheses were cemented centrally in this canal according to a standardized procedure. A servohydraulic testing machine was used to apply dynamic loads to the prosthetic head. Radiostereophotogrammetric analysis was used to measure rotations and translations between the prosthesis and bone. In addition, the reconstructions were loaded until failure in a static, displacement-controlled test. During the dynamic experiments, the femoral necks did not fail and no macroscopical damage was detected. Maximal values were found for normal walking with a mean rotation of about 0.2 degrees and a mean translation of about 120 microm. These motions stabilized during testing. The mean static failure load was 4714 N. The results obtained in this study are promising and warrant further development of this type of minimal invasive hip prosthesis.

Arthroplasty, Replacement, Hip↗

Finite element analysis of the long-term fixation strength of cemented ceramic cups.

Clinical studies have shown that adequate fixation of ceramic cups using bone cement is difficult to achieve. As the cement-ceramic bond strength is low, a satisfactory fixation strength requires a cup design that allows mechanical interlocking, although such a design will probably promote cement cracking and therefore cup loosening in the long term. An investigation has been carried out to establish whether a cemented ceramic cup can be designed in such a way that both a satisfactory initial fixation strength is obtained and cement cracking is reduced to levels found around PE cups functioning well in vivo. By means of finite element analysis, the fatigue loading of three geometrically different cemented acetabular cups, with ceramic and PE material properties, has been simulated, and the severity of the crack patterns produced in the cement has been analysed. Furthermore, the fixation strength has been analysed by simulating a pull-out test prior to and after fatigue testing. All ceramic cups produced much larger amounts of cement damage during fatigue testing than any PE cup, caused by stress concentrations in the cement that were attributable to the high stiffness of the ceramic. Even a completely smooth ceramic cup produced more damage than a sharp-grooved PE cup. Owing to the excessive cement cracking, the fixation strength of the ceramic cups dropped after fatigue loading. It is concluded that cemented ceramic cups have an increased risk of long-term mechanical failure by comparison with PE cups, and that a ceramic cup design that combines sufficient fixation strength with low cement failure may be difficult to achieve.

Acetabulum↗

The Ilizarov external fixator: what remains of the wire pretension after dynamic loading?

BACKGROUND: Maintenance of wire pretension in an Ilizarov external fixator is dependent on the torque applied to the fixation bolts. We therefore measured immediately after surgery the clinically applied torques. The median value was only 10 N m (range 8-14N m). We wondered whether this value is appropriate to maintain the wire pretension and thereby to achieve sufficient fracture stability during dynamic loading of the device for a longer period. METHODS: A material testing machine dynamically loaded one wire mounted on one ring. Several configurations were tested. RESULTS: A quick decrease in wire tension to a steady state situation was seen. In the most stable configuration (20 N m wire fixation torque) 50% of the initial 90 kg wire pretension remained after dynamic loading with 200 N. In the least stable configuration (10 N m torque) considerable wire slippage occurred even without loading and no tension remained after loading! No plastic deformation of the wires was observed so loss of wire tension was due to slippage of the wires through the fixation bolts. INTERPRETATION: With the small fixation torques used in clinical practice considerable wire tension is lost even after a few loading cycles. Further research should address the question whether preservation of a higher wire tension during long term loading promotes faster fracture healing.

Bone Wires↗

The difference in trochlear orientation between the natural knee and current prosthetic knee designs; towards a truly physiological prosthetic groove orientation.

The patella groove of total knee replacements has evolved from a groove with a neutral orientation to a groove with a lateral (also referred to as valgus) orientation. In this study the authors questioned whether femoral components with a lateral groove orientation more closely approximate the configuration in the natural knee. The groove orientations of an implanted CKS femoral component, available in different sizes and with different groove orientations, were determined and compared with formerly published measurements of the natural trochlear orientation. It was found that the prosthetic groove orientations differed considerably from human anatomy, up to a maximum deviation of 6.4 degrees. The orientations of the prosthetic grooves were all equal within the area of the natural trochlea. The area of the natural trochlea guides the patella between about 30 degrees and 120 degrees of knee flexion. The orientations of the prosthetic grooves were different in the area of the supracondylar pouch/proximal anterior flange. This area guides the patella between about 0 degrees and 30 degrees of knee flexion. As this study showed a considerable deviation between natural and prosthetic groove orientation, an optimal prosthetic groove orientation, matching the average orientation in the natural knee, was mathematically determined.

Arthroplasty, Replacement, Knee↗

A comparison of fatigue resistance of three materials for cusp-replacing adhesive restorations.

OBJECTIVES: To investigate the fatigue resistance and failure behaviour of cusp-replacing restorations in premolars using different types of adhesive restorative materials. METHODS: A class 2 cavity was prepared and the buccal cusp was removed in an extracted sound human upper premolar. By using a copy-milling machine this preparation was copied to 60 human upper premolars. In groups of 20 premolars each, direct resin composite restorations, indirect resin composite restorations and ceramic restorations were made. All restorations were cusp replacements made in standardized shape and with adhesive techniques. Cyclic load (5 Hz) was applied starting with a load of 200 N (10,000 cycles) followed by stages of 400, 600, 800 and 1000 N at a maximum of 50,000 cycles each. Samples were loaded until fracture or to 2,10,000 cycles maximum. In case of fracture, the failure mode was recorded. RESULTS: No differences were seen in fracture strength between the three groups (Wilcoxon P = 0.16). No differences were observed with regard to failure mode above or below the cemento enamel junctions (chi2 P = 0.63). The indirect resin composite and ceramic restorations showed significantly more combined cohesive and adhesive fractures than the direct resin composite restorations, which showed more adhesive fractures (chi2 P = 0.03 and 0.002). CONCLUSIONS: The results of this study suggest that ceramic, indirect resin composite and direct resin composite restorations provide comparable fatigue resistance and exhibit comparable failure modes in case of fracture, although the indirect restorations tend to fracture more cohesively than the direct restorations.

Acrylic Resins↗

Why would cement porosity reduction be clinically irrelevant, while experimental data show the contrary.

Laboratory bench tests have shown that porosity reduction increases the fatigue life of bone cement specimens. Clinically, however, the effect porosity reduction is subject to debate. We hypothesized that the discrepancy between clinical and experimental findings is related to differences in the stress distribution, which is typically uniform in experimental test specimens, while stress concentrations exist in cement around hip implants. We simulated fatigue failure of cement in a finite element model of an experimental test specimen and of a transverse slice of a total hip arthroplasty with a sharp-cornered stem. Four levels of porosity were introduced. In the fatigue test specimen model, the fatigue life clearly was dependent on the level of porosity, while in the transverse slice model, the level of porosity had virtually no effect on failure of the cement mantle. The results of the simulations confirmed our hypothesis. In simulations of laboratory tests, pores clearly acted as crack initiators, while in the simulation of a real total hip reconstruction, crack formation was governed by local stress singularities. This explains why the beneficial effect of cement porosity reduction on the lifetime of total hip reconstructions may be hard to detect clinically.

Arthroplasty, Replacement, Hip↗

Avoiding rotational malalignment after fractures of the femur by using the profile of the lesser trochanter: an in vitro study.

INTRODUCTION: Intramedullary (IM) nailing has become the preferred method of treatment for femoral shaft fractures in adults. Rotational malalignment is an important complication, established during operation. The incidence of rotational malalignment (> or = 15 degrees) has been reported to be between 20% and 30%. It might be avoided intra-operatively by using quantitative imaging techniques, with the profile of the contralateral lesser trochanter serving as a reference. MATERIALS AND METHODS: With the help of a C-arm image intensifier, five surgeons tried to determine the neutral state of ten prepared cadaver femora. They could only look at the C-arm screen and were blinded to the actual femur. Per observer three measurements were done per femur. The first measurement (method I) was done without a reference, while the second (method II) used a reference image of the femur in a neutral state. The third method (method III) added a lesser trochanter quantifying computer program. After positioning of the femur, the difference in rotational state compared with the neutral state was measured with an inclinometer. RESULTS: Without reference, malrotations up to 27 degrees were found. Methods II and III proved to be significantly better (p < 0.0001). These two methods showed malrotation of 2.2 degrees (+/-1.5 degrees) and 2.3 degrees (+/-1.7 degrees), respectively. External or internal malrotation occurred with all three methods equally frequently. No difference was found between observers. CONCLUSIONS: Using the contralateral lesser trochanter as a reference is an accurate method to minimize malrotation of a femur. Quantifying the profile of the lesser trochanter with computer assistance did not improve these results. Clinical results in the future still have to support these in vitro findings.

Bone Malalignment↗

Can internal stresses explain the fracture resistance of cusp-replacing composite restorations?

The aim of this study was to explore and compare the results of occlusal load application to cusp-replacing composite restorations, studied by means of finite element (FE) analysis and in vitro load tests. A three-dimensional (3D) FE model was created with a set up similar to an in vitro load test that assessed the fatigue resistance of upper premolars with buccal cusp-replacing resin composite restorations. Occlusal load was applied to two geometries (with and without palatal cuspal coverage), and the tooth-restoration interface and composite material stresses were calculated. Subsequently, safety factors were calculated by dividing the material strength values by the obtained stresses. The highest safety factors were observed for the restorations with cuspal coverage. This was consistent with the load test, in which cuspal coverage led to higher fracture resistance. Furthermore, the FE analysis predicted that failure of the tooth-restoration interface is more likely than failure of the composite material. Correspondingly, the load test showed predominantly adhesive failures of the restorations. Although the described test methods did not lead to a complete understanding of the failure mechanism, it can be concluded that the FE analysis provides additional information with regard to the differences in fracture behaviour of these types of restorations.

Adhesiveness↗

Cemented cup stability during lever-out testing after acetabular bone impaction grafting with bone graft substitutes mixes containing morselized cancellous bone and tricalcium phosphate--hydroxyapatite granules.

Bone defects after failed total hip arthroplasty can be reconstructed with impacted morselized bone grafts and a cemented cup. In the near future the amount of bone grafts available for surgical purposes will be insufficient. Ceramic calcium phosphates [tricalcium phosphate (TCP) and hydroxyapatite (HA)] have been widely considered as potential bone graft substitutes or bone graft extenders. In the past, mechanical experiments have been performed to determine implant stability of bone grafts and ceramic TCP-HA granules mixes under a compressive load. However, in-vivo migration studies suggest that shear loading may be equally important. This in-vitro study investigated the initial stability of cups reconstructed with various mixes of bone grafts and ceramic TCP-HA granules in a lever-out situation, where shearing is the predominant loading mode. It was found that the cups reconstructed with mixes of bone graft and TCP-HA granules exhibited greater mechanical stability than the cups reconstructed with bone grafts only. It is concluded that from a mechanical standpoint, when considering shear force resistance, 50-50 per cent volume mix and 25-75 per cent volume mix of morselized cancellous bone graft and TCP-HA granules both provide adequate initial cup stability and can be used for acetabular reconstructions with the bone impaction grafting technique.

Acetabulum↗

A three-dimensional dynamic finite element model of the prosthetic knee joint: simulation of joint laxity and kinematics.

For testing purposes of prostheses at a preclinical stage, it is very valuable to have a generic modelling tool, which can be used to optimize implant features and to avoid poor designs being launched on to the market. The modelling tool should be fast, efficient, and multi-purpose in nature; a finite element model is well suited to the purpose. The question posed in this study was whether it was possible to develop a mathematically fast and stable dynamic finite element model of a knee joint after total knee arthroplasty that would predict data comparable with published data in terms of (a) laxities and ligament behaviour, and (b) joint kinematics. The soft tissue structures were modelled using a relatively simple, but very stable, composite model consisting of a band reinforced with fibres. Ligament recruitment and balancing was tested with laxity simulations. The tibial and patellar kinematics were simulated during flexion-extension. An implicit mathematical formulation was used. Joint kinematics, joint laxities, and ligament recruitment patterns were predicted realistically. The kinematics were very reproducible and stable during consecutive flexion-extension cycles. Hence, the model is suitable for the evaluation of prosthesis design, prosthesis alignment, ligament behaviour, and surgical parameters with respect to the biomechanical behaviour of the knee.

Arthroplasty, Replacement, Knee↗

Finite-element analysis of failure of the Capital Hip designs.

The Capital Hip implant was a Charnley-based system which included a flanged and a roundback stem, both of which were available in stainless steel and titanium. The system was withdrawn from the market because of its inferior performance. However, all four of the designs did not produce poor rates of survival. Using a simulated-based, finite-element analysis, we have analysed the Capital Hip system. Our aim was to investigate whether our simulation was able to detect differences which could account for the varying survival between the Capital Hip designs, thereby further validating the simulation. We created finite-element models of reconstructions with the flanged and roundback Capital Hips. A loading history was applied representing normal walking and stair-climbing, while we monitored the formation of fatigue cracks in the cement. Corresponding to the clinical findings, our simulation was able to detect the negative effects of the titanium material and the flanged design in the Capital Hip system. Although improvements could be made by including the effect of the roughness of the surface of the stem, our study increased the value of the model as a predictive tool for determining failure of an implant.

Arthroplasty, Replacement, Hip↗

Mechanical testing of impaction bone grafting in the tibia: initial stability and design of the stem.

Clinical experience of impaction bone grafting for revision knee arthroplasty is limited, with initial stability of the tibial tray emerging as a major concern. The length of the stem and its diameter have been altered to improve stability. Our aim was to investigate the effect of the type of stem, support of the rim and graft impaction on early stability of the tray. We developed a system for impaction grafting of trays which we used with morsellised bone in artificial tibiae. Trays with short, long thick or long thin stems were implanted, with or without support of the rim. They were cyclically loaded while measuring relative movement. Long-stemmed trays migrated 4.5 times less than short-stemmed trays, regardless of diameter. Those with support migrated 2.8 times less than those without. The migration of short-stemmed trays correlated inversely with the density of the impacted groups. That of impaction-grafted tibial trays was in the range reported for uncemented primary trays. Movements of short-stemmed trays without cortical support were largest and sensitive to the degree of compaction of the graft. If support of the rim was sufficient or a long stem was used, impacted morsellised bone graft achieved adequate initial stability.

Arthroplasty, Replacement, Knee↗

Is hydroxyapatite cement an alternative for allograft bone chips in bone grafting procedures? A mechanical and histological study in a rabbit cancellous bone defect model.

To evaluate in vivo performance of hydroxyapatite cement (HAC) as a porous bone graft substitute, HAC was mixed (1:1 ratio) with either porous calcium-phosphate granules (80% tricalcium phosphate, 20% hydroxyapatite) or defatted morsellized cancellous bone (MCB) allograft and implanted bilaterally in cylindrical drill holes in distal femurs of rabbits. Groups with empty defects and impacted MCB were used for reference. After 8 weeks, one femur from each pair was examined histologically. All contralateral specimens and Time-0 specimens were used for mechanical indentation tests. Histology showed that some empty defects were filled with newly formed osteopenic bone after 8 weeks. The impacted MCB showed remodeling into new vital bone. Incorporation of the HAC/MCB composite was incomplete, whereas minimal new bone ingrowth was found in the HAC/granule composites. Though not different from each other, both composites were significantly stronger than empty defects, incorporated impacted MCB, and intact cancellous bone. At Time 0, the mechanical behavior of impacted MCB was similar to both HAC composites. In conclusion, composites of HAC and porous biomaterials can maintain relatively high strength over 8 weeks in vivo, but their incorporation into a new bony structure is slower than impacted MCB. The HAC/MCB composite showed favorable incorporation behavior.

Animals↗

Displacement of the medial meniscus within the passive motion characteristics of the human knee joint: an RSA study in human cadaver knees.

The objective of this study was to validate an in vitro human cadaver knee-joint model for the evaluation of the meniscal movement during knee-joint flexion. The question was whether our model showed comparable meniscal displacements to those found in earlier meniscal movement studies in vivo. Furthermore, we determined the influence of tibial torque on the meniscal displacement during knee-joint flexion. Three tantalum beads were inserted in the medial meniscus of six human-cadaver joints. The knee joints were placed and loaded in a loading apparatus, and the movements of the beads were determined by means of RSA during knee-joint flexion and extension with and without internal tibial (IT) and external tibial (ET) torque. During flexion without tibial torque, all menisci moved in posterior and lateral direction. The anterior horn showed significantly greater excursions than the posterior horn in both posterior and lateral direction. Internal tibial torque caused an anterior displacement of the pathway on the tibial plateau. External tibial torque caused a posterior displacement of the pathway. External tibial torque restricted the meniscal displacement during the first 30 degrees of knee-joint flexion. The displacements of the meniscus in this experiment were similar to the displacements described in the in vivo MRI studies. Furthermore, the application of tibial torque confirmed the relative immobility of the posterior horn of the meniscus. During external tibial torque, the posterior displacement of the pathway on the tibial plateau during the first 30 degrees of flexion might be restricted by the attached knee-joint capsule or the femoral condyle. This model revealed representative meniscal displacements during simple knee-joint flexion and also during the outer limits of passive knee-joint motion.

Aged↗

Computed tomography determined femoral torsion is not accurate.

INTRODUCTION: Computed tomography (CT) is considered the method of choice for detecting rotational malalignment of the femur. However, it is unclear how reliable the method is, and what the causes are of potential inaccuracies. MATERIALS AND METHODS: To address these issues three observers measured the CT images of the femur of 76 patients on two separate occasions. The images were made during follow-up of a unilateral femoral shaft fractures. Rotational malalignment was determined by comparing the torsion angle of the injured to the noninjured leg. RESULTS: The pooled intraobserver variance was 3.9 degrees and interobserver variance 4.1 degrees. Of the two measurements of one observer 95% were up to 10.8 degrees different, and between observers 95% of the measurements were up to 15.6 degrees different. CONCLUSIONS: CT measurements of rotational malalignment of the femur are not accurate. This is due principally to the difficulty in defining a line through the axis of the femoral neck. The accuracy can be improved by taking the average of two measurements.

Bone Malalignment↗

Prosthetic replacement of the medial meniscus in cadaveric knees: does the prosthesis mimic the functional behavior of the native meniscus?

UNLABELLED: Meniscus replacement by a polymer meniscus prosthesis in dogs resulted in generation of new meniscal tissue. HYPOTHESIS: Optimal functioning of the prosthesis would involve realistic deformation and motion patterns of the prosthesis during knee joint motion. STUDY DESIGN: Controlled laboratory study. METHODS: The movements of the meniscus were determined during knee joint flexion and extension with and without internal and external tibial torque by means of roentgen stereophotogrammetric analysis. Subsequently, the meniscus in 6 human cadaveric knee joints was replaced by a meniscus prosthesis. RESULTS: All different parts of the meniscus showed a posterior displacement during knee joint flexion. The anterior horn was more mobile than the posterior horn. The prosthesis mimicked the movements of the meniscus. However, the excursions of the prosthesis on the tibial plateau were less. The knee joint laxity was not significantly higher after replacement with the meniscus prosthesis. CONCLUSIONS: The prosthesis approximated the behavior of the native meniscus. Improvement in both the gliding characteristics of the prosthetic material and the fixation of the prosthesis may improve the function. CLINICAL RELEVANCE: The meniscus prosthesis needs to be optimized to achieve a better initial function in the knee joint.

Aged↗