PubMed Health⌕ Search

Biomedical subjects

N Y Boo

Publications and source records attributed to N Y Boo.

At least 19 recordsLinked to original sources

G6PD deficiency with hemolytic anemia due to a rare gene deletion--a report of the first case in Malaysia.

A 2-year-old Chinese boy was referred to Hospital UKM for investigation of recurrent episodes of dark-coloured urine and pallor since birth. He was born prematurely at 34 weeks gestation and developed severe early-onset neonatal jaundice requiring exchange blood transfusion. Screening at birth showed Glucose-6-phosphate dehydrogenase (G6PD) deficiency. On admission, physical examination revealed pallor, jaundice and mild hepatomegaly. Results of laboratory investigations showed a hemoglobin level of 11.0 g/dl with a hemolytic blood picture, reticulocytosis of 20% and red cell G6PD activity reported as undetectable. The patient's DNA was analysed for G6PD mutations by PCR-based techniques and DNA sequencing and results showed a 24 bp deletion of nucleotide 953-976 in the exon 9 of the G6PD gene. DNA analysis was also performed on blood samples of the patient's mother and female sibling confirming their heterozygous status, although both showed normal red cell G6PD activity levels. The patient was discharged well and his parents were appropriately advised on the condition and the importance of taking folic acid regularly. This is a first case report in Malaysia of G6PD deficiency causing chronic-hemolytic anemia. The rare 24 bp deletion causes the G6PD Nara variant, previously reported only in two other unrelated males, a Japanese and a Portuguese both with chronic hemolytic anemia.

Anemia, Hemolytic↗

Newborn hearing screening: experience in a Malaysian hospital.

INTRODUCTION: This study aims to determine the prevalence of hearing loss among newborns delivered at Hospital Universiti Kebangsaan Malaysia and to evaluate the usefulness of our hearing screening protocol. METHODS: All infants born in the hospital over a nine-month period, between April to December 2003, were screened for hearing loss with a portable otoacoustic emission (OAE) before discharge. At the age of two months, a second OAE test was repeated on newborns who failed the initial test. Those who failed the second test were re-tested at three months of age. When these infants failed the third OAE test, a brainstem evoked response (BSER) test was performed. RESULTS: During the study period, 4,219 infants were born in the hospital, and 3,762 (89.2 percent) underwent OAE screening. 620 (19.7 percent) of them failed the first screening test, and 506 (81.6 percent) of them came for a second stage-screening test. In the third stage screening at three months of age, only 39 (65 percent) patients turned up. Of these, ten infants passed the OAE test and 29 failed. However, when these infants underwent BSER, 13 had normal BSER and 16 have abnormal BSER. The prevalence of hearing loss in this study was 0.42 percent (16/3,762). CONCLUSION: The large number of defaulters and false-positive results in this study suggest that this pilot hearing-screen programme requires fine-tuning to minimise these problems.

Audiometry, Evoked Response↗

Unbalanced chromosomal translocation: a cause of recurrent spontaneous abortion.

Recurrent spontaneous abortion, defined as three consecutive abortions, occurs in approximately 1% to 2% of couples. Although the cause is unknown in up to 50% of cases, about 5% of these couples are found to be a balanced translocation carrier. We report a case in which the mother was identified to be a translocation carrier following the birth of a baby with multiple congenital abnormalities.

Abortion, Spontaneous↗

A randomised control trial of clingfilm for prevention of hypothermia in term infants during phototherapy.

INTRODUCTION: This study aimed to compare the core, abdominal wall, and plantar temperatures of well jaundiced term infants undergoing phototherapy with or without clingfilm covering the lower two-thirds of the upper end of their bassinets. METHODS: This was a randomised controlled trial carried out in a tertiary university hospital on normal healthy term infants undergoing phototherapy. 106 eligible infants were randomised to receive phototherapy with (n=52) or without (n=54) the use of clingfilm during a two-hour period. Subsequently, after nappy change and feeding, they were crossed over to receive phototherapy without or with the clingfilm in place, respectively. Their body temperatures were measured at zero and two hours after phototherapy. RESULTS: There was no significant difference in their core, abdominal wall and plantar temperatures at baseline and after two hours of phototherapy (p-value is greater than 0.05) between infants with and without the use of clingfilm. Irrespective of the use of clingfilm, there was significant (p-value is less than 0.001) increase in core body temperatures after two hours of continuous phototherapy, with resultant hyperthermia (greater than 37.5 degree Celsius) in 42 percent of infants when under clingfilm and 35.8 percent when without clingfilm. A few (2.8 percent) infants, though statistically not significant, became mildly hypothermic after two hours of phototherapy when clingfilm was not used (p-value is greater than 0.05). CONCLUSION: Hyperthermia was common during phototherapy, irrespective of the use of clingfilm. Hypothermia was rare and the preventive role of clingfilm is not certain.

Body Temperature↗

Predictors of failed closure of patent ductus arteriosus with indomethacin.

INTRODUCTION: The aim of this study was to determine predictors of failed closure of patent ductus arteriosus (PDA) following a single course of indomethacin in symptomatic preterm infants. METHODS: This prospective observational study was carried out on 60 preterm infants weighing less than 1,750 g with symptomatic PDA confirmed by echocardiography. At a median age of 7.0 days (interquartile range 4.0), they were given indomethacin of 0.1 mg/kg/day intravenously daily for six days. Closure of PDA was reassessed by echocardiography upon completion of therapy. RESULTS: The PDA of 40 percent (n=24) of these infants remained patent. Forward logistic regression analysis showed that the only significant predictors of failed PDA closure in these infants were: PDA size (adjusted odds-ratio [OR] is 7.0; 95 percent confidence interval [CI] of OR is 2.0, 24.8; p-value is 0.002), birth weight (adjusted OR is 0.996; 95 percent CI of OR is 0.993, 1.000; p-value is 0.03) and platelet count (adjusted OR is 0.987; 95 percent CI is 0.975, 1.000; p-value is 0.045). Gestational age, maternal age and left atrium/aorta ratios were not significant predictors. CONCLUSION: Larger PDA, lower birth weight and lower platelet count were significant predictors of high failure in indomethacin therapy given late at one week of life.

Cyclooxygenase Inhibitors↗

Effectiveness of a simple heated water-filled mattress for the prevention and treatment of neonatal hypothermia in the labour room.

INTRODUCTION: This study aimed to determine the proportions of normothermic infants who remained normothermic, and hypothermic infants who became normothermic following the use of a heated water-filled mattress (HWM) in the labour room. METHODS: A prospective observational study carried out in the labour room over a 2.5 month period on 228 well term infants delivered by lower segment caesarean section (LSCS) in the operating theatre (environmental temperature 18 degrees Celsius). Upon arrival in the labour room, the infants were placed on a HWM in a nursing cot. The axillary temperature was measured using a mercury thermometer for three minutes. Each infant was then wrapped with a large piece of linen, and covered with a blanket. Just before transfer to postnatal wards, the axillary temperature was re-measured. RESULTS: 52.2 percent (119/228) of infants were hypothermic (temperature less than 36.5 degrees Celsius) upon arrival in the labour room. Before leaving the labour room, the median increase in axillary temperature of the initially hypothermic infants was significantly higher (0.2 degrees Celsius, interquartile range 0.5) than those initially normothermic infants (0.0 degrees Celsius, interquartile range 0.3) (p-value is less than 0.00001). Among the initially hypothermic infants, 40.3 percent (48/119) became normothermic before transfer to postnatal wards. The significant independent risk factors associated with persistent hypothermia were lower birthweight (p-value equals 0.02), lower gestational age (p-value equals 0.02) and shorter duration on the warming mattress (p-value equals 0.08). Among 109 initially normothermic infants, 17.4 percent became mildly hypothermic (mean axillary temperature 36.2 degrees Celsius, standard deviation 0.2) before leaving the labour room. CONCLUSION: The HWM is a reasonably effective simple device for the prevention and treatment of hypothermia in the labour room.

Beds↗

Turn-around-time of radiographs in a neonatal intensive care unit.

A quality assurance study was carried out prospectively in two phases at the Neonatal Intensive Care Unit (NICU) of Hospital Universiti Kebangsaan Malaysia. The objectives of the study were to determine the turn-around-time (TAT) of radiographs requested for infants undergoing intensive care treatment in the NICU and the effects of a standard operating procedure introduced based on initial findings of first phase of the study on subsequent TAT. The TAT was defined as the time taken for the radiograph to be ready for viewing after the attending doctor had requested for it to be done on an infant. During phase one of the study, none of the requested radiographs was ready to be viewed by the doctors within the standard TAT of 45 minutes. The problems identified were ward staffs delay in sending request forms to the radiology department, radiographers' delay in shooting and processing the films, and delay by NICU porter in collecting the processed films. Based on these findings, a standard operating procedure (SOP) was drawn up jointly by the staff of NICU and Department of Radiology. During phase two of the study conducted at one month after implementation of the SOP, there was a reduction of TAT by 50%. However, only 3 (4.3%) of the radiographs achieved the standard TAT. The main problems identified during phase two were delay in sending request forms and in collecting processed radiographs by the porter system. The dismal TAT of radiographs in NICU was related primarily to human behaviour. Besides continuous staff education, replacement of the porter system with electronic system may improve the TAT.

Humans↗

The effect of a user-guided request form for chest radiographs in a neonatal intensive care unit.

The objectives of this prospective, observational study were to determine the current indications of requesting chest radiograph in sick infants in a neonatal intensive care unit (NICU) and the effect of a user-guided request form for chest radiographs of sick infants. During the three-month study period, a total of 423 chest radiographs were requested on 159 sick newborn infants in the intensive area of this NICU. A majority (55.6%) of these chest radiographs were performed to verify positions tips of either central catheters (27.4%) or endotracheal tubes (28.1%). The number of chest radiographs done during the period when the user-guided request forms were utilised was significantly lower (1.24 per patient) than before (1.37 per patient) or after (1.58 per patients) the period when these forms were in use (p=0.01). The rate of radiological abnormalities detected in radiographs requested to verify position of tips of endotracheal tubes were significantly greater during the period when user-guided forms were used than when they were not (p=0.01). A significantly higher proportion of changes in management were instituted when the user-guided forms were in use than during the period when they were not used (p=0.03). We conclude that a user-guided radiographic request form helps doctors in NICU to carry out their management more effectively.

Follow-Up Studies↗

Congenital factor VII deficiency: a case report.

Factor VII deficiency is a rare congenital blood disorder. Its clinical features are rather variable and ranges from epistaxis to massive intracranial haemorrhage. Treatment involves replacement therapy, which constitutes use of fresh frozen plasma, prothrombin complex concentrates or recombinant activated factor VII. Although it is a rare entity, one still needs to consider it as a probable diagnosis in a newborn with coagulopathy. We report here a case of Factor VII deficiency in a newborn who presented with subdural haemorrhage at day 4 of life.

Blood Component Transfusion↗

Glucose-6-phosphate dehydrogenase (G6PD) variants in Malaysian Malays.

We performed DNA analysis using cord blood samples on 86 male Malay neonates diagnosed as G6PD deficiency in the National University of Malaysia Hospital by a combination of rapid PCR-based techniques, single-stranded conformation polymorphism analysis (SSCP) and DNA sequencing. We found 37.2% were 871G>A (G6PD Viangchan), 26.7% were nt 563 C>T (G6PD Mediterranean) and 15.1% were 487G>A (G6PD Mahidol) followed by 4.7% 1376G>T (G6PD Canton), 3.5% 383T>C (G6PD Vanua Lava), 3.5% 592C>T (G6PD Coimbra), 2.3% 1388G>A (G6PD Kaiping), 2.3% 1360C>T (G6PD Union), 2.3% 1003G>A (G6PD Chatham), 1.2% 131C>G (G6PD Orissa) and 1.2% 1361G>A (G6PD Andalus). Seventy-one (82.6%) of the 86 G6PD-deficient neonates had neonatal jaundice. Fifty seven (80%) of the 71 neonates with jaundice required phototherapy with only one neonate progressing to severe hyperbilirubinemia (serum bilirubin >340 micromol/l) requiring exchange transfusion. There was no significant difference in the incidence of neonatal jaundice, mean serum bilirubin level, mean age for peak serum bilirubin, percentage of babies requiring phototherapy and mean number of days of phototherapy between the three common variants. In conclusion, the molecular defects of Malay G6PD deficiency is heterogeneous and G6PD Viangchan, Mahidol and Mediterranean account for at least 80% of the cases. Our findings support the observation that G6PD Viangchan and Mahidol are common Southeast Asian variants. Their presence in the Malays suggests a common ancestral origin with the Cambodians, Laotians and Thais. Our findings together with other preliminary data on the presence of the Mediterranean variant in this region provide evidence of strong Arab influence in the Malay Archipelago.

DNA Mutational Analysis↗

Semiquantitative screening test for G6PD deficiency detects severe deficiency but misses a substantial proportion of partially-deficient females.

Neonatal screening for G6PD deficiency has long been established in many countries. The aim of the study was to determine whether the routine semiquantitative fluorescent spot test could detect all cases of G6PD deficiency, including those cases with partial deficiency (residual red cell G6PD activity between 20-60% of normal). We compared the results of G6PD screening by the semiquantitative fluorescent spot test and quantitative G6PD activity assay on a group of 976 neonates and 67 known female heterozygotes. The values for mean G6PD activity of G6PD-normal neonates and 293 healthy adult females were determined. There was no significant difference in the mean normal G6PD activity between the two racial groups in the neonates (669 Malays, 307 Chinese) and in the 293 healthy adult females (150 Malays, 143 Chinese) group. The values for the upper limits of total deficiency (20% of normal residual activity) for neonates and adult females were 2.92 U/gHb and 1.54 U/gHb, respectively. The upper limits of partial deficiency (60% of normal residual activity) were 8.7 U/gHb and 4.6 U/gHb respectively. The prevalence of G6PD deficiency among the male neonates was 5.1% (26) by both the fluorescent spot test and the enzyme assay method. The G6PD activity levels of all 26 cases of G6PD-deficient male neonates were < 20% normal (severe enzyme deficiency). In the female neonate group, the frequency of G6PD deficiency was 1.3% (6 of 472) by the fluorescent spot test and 9.35% (44 of 472) by enzyme assay. The 6 cases diagnosed as deficient by the fluorescent spot test showed severe enzyme deficiency (< 2.92 U/gHb). The remaining 38 female neonates had partial enzyme deficiency and all were misdiagnosed as normal by the fluorescent spot test. In the female heterozygote group, G6PD deficiency was diagnosed in 53% (35 of 67) by enzyme assay and in 7.5% (4 of 67) of cases by the fluorescent spot test. The 4 cases detected by fluorescent spot test had severe enzyme deficiency (<1.6 U/gHb). The remaining 31 (46.3%) cases, diagnosed as normal by fluorescent spot test, showed partial G6PD deficiency. In conclusion, we found that the semiquantitative fluorescent spot test could only diagnose cases of total G6PD deficiency and misclassified the partially-deficient cases as normal. In this study, the overall prevalence of G6PD deficiency was 3.28% by the semiquantitative fluorescent spot test and 7.17% by enzyme assay. This means that 3.9% of G6PD-deficient neonates were missed by the routine fluorescent spot test and they were found to be exclusively females. This study demonstrates a need to use a method that can correctly classify female heterozygotes with partial G6PD deficiency. The clinical implication is that these individuals may be at risk of the hemolytic complication of G6PD deficiency.

Adult↗

Randomized controlled study of the effects of different durations of light exposure on weight gain by preterm infants in a neonatal intensive care unit.

UNLABELLED: A randomized controlled study was carried out on 96 preterm infants (< 37 wk) with birthweight less than 2000 g admitted to a neonatal intensive care unit. The aim was to compare the weight gain between preterm infants exposed to 12 h cyclical lighting (intensity of light: 78.4 +/- 24.7 lux, mean +/- SD) and those exposed to a continuously dim environment (5.9 +/- 1.9 lux). The exclusion criteria were infants with major congenital malformations or who needed continuous lighting for treatment procedure and care. From day 7 of life until discharge, 50 infants were randomized to receive 12 h cyclical lighting and 46 infants to a continuously dim environment. There was no significant difference in the mean birthweight (12 h lighting vs continuously dim: 1482 vs 1465 g, p = 0.8), mean gestational age (31.6 vs 31.4 wk, p = 0.6), median duration of hospital stay (28.5 vs 28.5 d, p = 0.8), mean age to regain birthweight (13.0 vs 12.9 d, p = 0.3), mean weight gained by day 14 (27.6 vs 36.2 g, p = 1.0), median weight gain per day (11.9 vs 12.2 g, p = 0.9) or median body weight on discharge (1800 vs 1800 g, p = 0.4) between the two groups of infants. CONCLUSION: Exposing preterm infants to either 12 h cyglical lighting or continuously dim environment did not have any significant effect on their weight gain during the neonatal period.

Apgar Score↗

Randomized controlled trial of heparin for prevention of blockage of peripherally inserted central catheters in neonates.

AIM: To determine whether the addition of heparin to total parenteral nutrition (TPN) fluid would prevent blockage of peripherally inserted central catheters (PICCs) in neonates. METHODS: This was a randomized, double-blind, controlled study of 66 eligible neonates with PICCs inserted for the administration of TPN. Infants were randomized to receive TPN containing either 1 IU ml(-1) of heparin (n = 35) or no heparin (n = 31). RESULTS: There was no significant difference in the incidence of blocked catheters between the two groups of infants (heparin: 14.3%; no-heparin: 22.6%, p = 0.4). Although a higher percentage (62.9%) of infants in the heparin group received a complete course of TPN successfully via PICC than those in the no-heparin group (48.4%), the difference was not statistically significant (p = 0.3). There were no significant differences in the incidence of catheter-related sepsis, hypertriglyceridaemia, hyperbilirubinaemia, coagulopathy or intraventricular haemorrhage between the two groups. CONCLUSION: Addition of heparin to TPN fluid was not associated with a significant reduction in the incidence of blocked PICCs. However, the sample size of this study was too small to exclude even rather marked differences between the groups.

Catheterization, Central Venous↗

Diffuse neonatal haemangiomatosis: a rare cause of haemorrhagic shock and refractory coagulopathy in the newborn.

A term newborn infant developed hypovolaemic shock shortly after birth. She was pale with gross hepatomegaly. She required multiple boluses of intravenous fluids, blood products as well as inotropic support. Blood investigations showed persistent thrombocytopenia, anaemia and disseminated intravascular coagulopathy (DIC). She also developed heart failure. She finally succumbed on the eleventh day of life. Autopsy revealed haemangiomatosis involving the liver, lungs, gastrointestinal tract, kidneys and adrenals.

Adrenal Gland Neoplasms↗

Neonatal resuscitation training program in Malaysia: results of the first 2 years.

OBJECTIVES: To determine the number of providers and instructors trained by the initial 37 core instructors during the first 2 years following the launch of the Malaysian Neonatal Resuscitation Program (NRP). To identify remediable problems which interfered with the propagation of the NRP in Malaysia. METHODOLOGY: A prospective observational study carried out over a 2-year period between 2 September 1996 to 2 September 1998. For every training course conducted, the instructors completed a NRP course report form (Form A) that documented the instructors involved in the course. For every participant who attended the course and successfully completed it, the instructors submitted a record form (Form B) that contained the name, hospital address, department, profession, place of work, language used for training and the marks obtained by the individual participant. After each course, completed forms A and B were returned to the NRP secretariat for compilation. RESULTS: Of the 37 core instructors, 35 (94.6%) carried out training courses in their respective home states. A further 513 new instructors and 2256 providers were trained subsequently. A total of 2806 health personnel from all 13 states of Malaysia were NRP-certified during the first 2 years. However, 61.2% (n = 335) of the 550 instructors were inactive trainers, having trained less than four personnel per instructor a year. Most of the NRP-certified personnel were either doctors (32.0%) or nursing staff (64.4%). More than 60% of these worked either in the labour rooms, neonatal intensive care units or special care nurseries. At least one person from all three university hospitals and all general hospitals, 89.3% (92/103) of the district hospitals, 3.5% (73/2090) of the maternal and child health services, and 21% (46/219) of the private hospitals and maternity homes, were trained in the NRP. CONCLUSION: Dissemination of the NRP in Malaysia during the first 2 years was very encouraging. Further efforts should be made to spread the program to private hospitals and the maternal and child health services. In view of the large number of inactive instructors, the criteria for future selection of instructors should be more stringent.

Cohort Studies↗

Predictors of neurodevelopmental outcome of Malaysian very low birthweight children at 4 years of age.

OBJECTIVE: To determine neonatal, early developmental and social risk factors that predict the neurocognitive and behavioural outcome of very low birthweight (VLBW) preschool children at four years of age. METHODOLOGY: From a cohort of 151 eligible VLBW survivors born in Kuala Lumpur Maternity Hospital, 116 (76.8%) were prospectively followed up from birth till four years. A standardised neurological examination was performed at one and four years to determine the presence of impairment and cerebral palsy, respectively. Cognitive development was assessed using the Mental Scale of the Bayley Scales of Infant Development (MDI) at one year and the Weschler Preschool and Primary Scale of Intelligence-Revised (WIPPSI-R) at four years. Motor coordination was assessed using the Movement Assessment Battery for Children (Movement-ABC). Mothers completed the Child Behaviour Checklist (CBCL) and Parenting Stress Index (PSI) questionnaires. Logistic and multiple regression analyses were used to determine factors associated with cerebral palsy, IQ scores, Movement-ABC and CBCL scores. RESULTS: Factors associated with cerebral palsy were lower MDI scores at one year (P = 0.001) and late neonatal cranial ultrasound abnormalities (P = 0.036). Minor (P = 0.016) or major impairment (P = 0.003) at one year of age and a low level of paternal education (P = 0.01) were associated with poor motor function on the Movement-ABC scale. Lower levels of maternal education (P < 0.001), impairment at one year (P = 0.002) and late neonatal cranial ultrasound abnormalities (P = 0.039) predicted Full Scale IQ scores. Higher PSI scores (P = 0.001), younger mothers (P = 0.003) and late neonatal cranial ultrasound abnormalities (P = 0.009) were associated with worsened child behaviour scores on the CBCL scale. CONCLUSION: Social factors and the caregiving environment were important determinants of cognitive and behavioural outcome. Cranial ultrasound abnormalities in the late neonatal period and the developmental status at one year might be useful in identifying high risk infants in need of long-term surveillance.

Child Development↗