Strain-controlled enzymatic cleavage of collagen in loaded matrix.

The purpose of this investigation is to support the novel hypothesis that collagenous matrices are intrinsically "smart" load-adapting biomaterials. This hypothesis is based fundamentally on the postulate that tensile strain directly modulates the susceptibility of collagen molecules to enzymatic degradation (i.e., protects molecules which are under load from cleavage). To test this postulate, collagenase (Clostridiopeptidase A) was applied to a uniaxially loaded, anisotropic, devitalized, collagenous matrix in which a subset of fibrils was loaded in tension while the remaining fibrils carried little or no load. The collagen degradation pattern (as assessed by polarization and transmission electron microscopy) was found to correspond inversely to the tensile stress field such that fibrils under lower tensile load were preferentially cleaved. These results have immediate implications for tissue engineering of load-bearing collagenous matrices in vitro and may contribute significantly to our understanding of synthesis, remodelling, and pathogenesis of collagen matrices in vivo.

Catalysis↗

Local application of rhTGF-beta2 enhances peri-implant bone volume and bone-implant contact in a rat model.

Orthopedic and dental implant fixation depends upon bone regeneration. Growth factors such as transforming growth factor-beta (TGF-beta) have been shown to enhance bone repair and strengthen the mechanical connection between implant and host skeleton in canine models. To provide a platform for studying molecular mechanisms of growth factor stimulated bone regeneration and implant fixation, the present study examined peri-implant bone volume as a response to TGF-beta treatment in a rodent model. The rat femoral ablation model in which an implant is placed in the medullary cavity of the femur was used to examine the dose response to TGF-beta2 applied to the implant (0, 0.1, 1.0, or 10 microg). The study included a total of 40 rats (10 per dose) examined at 28 days. Peri-implant bone volume and bone-implant contact were assessed through microcomputed tomography and implant fixation strength was determined by a mechanical pullout test. Treatment of the implant with 10 microg TGF-beta2 led to a 2-fold increase in bone volume (P<0.001) and a 1.5-fold increase in bone-implant contact (P<0.01) with a trend of increasing fixation strength (non-significant increase of 1.4-fold). TGF-beta2 treatment with 10 microg led to uniform peri-implant bone volume and bone-implant contact along the length of the implant, whereas the other groups had less bone at the mid-point compared to the proximal and distal aspects of the implant. About 50% of the variance in implant fixation strength was explained by a regression model involving both bone-implant contact and peri-implant bone volume.

Animals↗

The biology of alternative bearing surfaces in total joint arthroplasty.

Periprosthetic osteolysis is currently the dominant limiting factor in joint arthroplasty longevity. Because this process is predominantly a biologic response to particulate wear debris and/or corrosion products, alternative bearing surfaces and highly cross-linked polyethylenes have been developed in an attempt to reduce the incidence of wear-induced periprosthetic osteolysis. These alternative bearing surfaces currently include ceramic-on-polyethylene, ceramic-on-ceramic, metal-on-metal, and metal or ceramic on highly cross-linked polyethylene. Although these alternative bearings diminish the generation of polyethylene debris, metallic or ceramic debris is produced. In addition, the biologic response to debris generated from alternate bearings is not fully elucidated and is related not only to particle number, but also to particle size, shape, composition, and surface area.

Arthroplasty, Replacement↗

Can metal levels be used to monitor metal-on-metal hip arthroplasties?

In this review, the prospects for using blood, serum, and/or urine metal levels for monitoring the performance of metal-on-metal hip arthroplasty systems are explored. This approach does have substantial potential for serving this function; however, the methodology is technically challenging and the interpretation of the values requires an extensive database with correlative clinical information. At this time, it is premature to recommend metal concentration analysis on a routine clinical basis for patients with metal-on-metal total hip arthroplasties. Nonetheless, metal concentration analysis remains a powerful research tool in the evaluation of metal-on-metal hip arthroplasty systems.

Arthroplasty, Replacement, Hip↗

Spinal implant debris-induced osteolysis.

STUDY DESIGN: Generally, implant-induced osteolysis is a manifestation of an adverse cellular response to phagocytosable particulate wear and corrosion debris. Initially termed "cement disease," particle-induced loosening was recognized by Charnley in the early 1960s. Despite the plethora of information gained over the last 40 years on the basic science of periprosthetic bone loss, much remains unanswered. The effect of unintended debris resulting from wear and corrosion (e.g., micromotion between the interconnection mechanisms in spinal implants) remains a clinical concern. The current study highlights what is known of particle-induced osteolysis and how the presence of spinal implant particulate debris deleteriously influences osseointegration of posterolateral bone graft or disrupts an established posterolateral fusion mass. Tissue explant, animal, and cell culture studies have revealed the complexity of cellular reactivity involved in aseptic particle-induced osteolysis. OBJECTIVES: The objectives of this study are twofold: 1) to highlight the dominant cellular participants in total joint arthroplasty particle induced osteolysis, which are purportedly the macrophage, osteoblast, fibroblast, and osteoclast and several of the dominant chemical mediators have been identified as well, which include prostaglandin E2, tumor necrosis factor-alpha, interleukin-1, and interleukin-6; and 2) to demonstrate the potential deleterious effects of spinal implant debris using animal models and analysis of soft tissue surrounding spinal implants in symptomatic patients. METHODS: There are a growing number of proinflammatory and anti-inflammatory cytokines, prostenoids, and enzymes that have been shown to play important roles in the pathology of particle-induced osteolysis. Reports that aseptic granulomatous inflammation typical of that associated with corrosion debris appear to correlate with the complexity of the implant. Titanium particulate material was used to induce effects in 34 New Zealand White rabbits where analysis included serological quantification of systemic cytokines. Postmortem microradiographic, immunocytochemical, and histopathologic assessment of the intertransverse fusion mass quantified the extent of osteolysis, local proinflammatory cytokines, osteoclasts and inflammatory infiltrates. Clinical analysis of 12 patients more than 0.4 years after spinal implants (mean 4.03, range 0.4 to 11 years) presented with late operative site pain. RESULTS: Currently the etiology of this inflammation around spinal implants resembles particle-induced osteolysis around joint arthroplasties where there typically is a self-perpetuating fibroinflammatory zone adjacent to the implant, where macrophage exhaustion, reactive oxygen intermediates, and pro-inflammatory cytokines affect a host of local cell types and induce a widening zone of soft tissue damage and inflammation. Animal model analysis indicated increased levels of local inflammatory cytokines typically associated with osteolysis-tumor necrosis factor-alpha. Osteoclast cell counts and regions of osteolytic resorption lacunas were higher in the titanium-treated versus autograft-alone groups (P < 0.05), and the extent of cellular apoptosis was markedly higher in the titanium-treated sites at both time intervals. Electron microscopy indicated definitive evidence of phagocytized titanium particles and foci of local, chronic inflammatory changes in the titanium-treated sites. CLINICAL CASES: 11 of 12 clinical cases demonstrated elevated tumor necrosis factor-alpha levels and an increased osteoclastic response in the vicinity of wear debris caused by dry frictional wear particles of titanium or stainless steel. Resection of the wear debris and surrounding fibroinflammatory zone resolved clinical symptoms in all 12 cases. CONCLUSIONS: More basic science and clinical research is needed to develop novel strategies for gaining knowledge, and developing effective evaluation and treatment of patients with implant debris related osteolysis. Titanium debris simulating that produced by spinal implants introduced at the level of a spinal arthrodesis elicits an inflammatory cytokine mediated particulate-induced response through increased expression of intracellular TNF-alpha, increased osteoclastic activity and cellular apoptosis. This study highlighted the association between spinal implants particulate wear debris and increased potential for osteolysis. Aseptic osteolysis is among the primary reasons for failure of orthopedic implants. Increased awareness of this destructive process is becoming more important with the growing popularity of total disc arthroplasty and highly modular spinal implants.

Adult↗

Metal degradation products: a cause for concern in metal-metal bearings?

In the majority of patients, orthopaedic implants are biocompatible. However, there is an increasing recognition that, in the long-term, permanent orthopaedic implants may be associated with adverse local and remote tissue responses in some individuals. These adverse effects are mediated by the degradation products of implant materials. The recent reintroduction of metal-on-metal bearings for total hip arthroplasty has heightened concerns about the biologic response to metal degradation products in light of the fact that the serum and urine metal concentrations in patients with these implants typically are higher than those seen in patients with conventional metal-on-polyethylene bearings. From previous studies of long-term metal-on-metal McKee-Farrar implants, it seems that these elevated levels may persist for the duration of the implant's lifetime. This is of particular concern in the younger and more active patient in whom life expectancy after implantation may exceed 30 years. The association of metal release from orthopaedic implants with any metabolic, bacteriologic, immunologic, or carcinogenic toxicity currently remains conjectural because cause and effect have not been established in human subjects. However, continued surveillance of patient populations with metal implants, particularly those with metal-metal bearings, is warranted.

Foreign Bodies↗

The effect of titanium particulate on development and maintenance of a posterolateral spinal arthrodesis: an in vivo rabbit model.

STUDY DESIGN: The current study was undertaken to determine if the presence of titanium wear particulate deleteriously influences early osseointegration of posterolateral bone graft or disrupts an established posterolateral fusion mass. OBJECTIVES: Using an in vivo animal model to evaluate the effect(s) of titanium wear particulate on a posterolateral spinal arthrodesis based on serologic, histologic, and immunocytochemical analyses. SUMMARY OF BACKGROUND DATA: The effect of unintended wear particulate resulting from micromotion between the interconnection mechanisms in spinal instrumentation remains a clinical concern. METHODS: Thirty-four New Zealand White rabbits were randomized into two groups based on postoperative time periods of 2 months (Group 1, n = 14) and 4 months (Group 2, n = 20). Group 1 underwent a posterolateral arthrodesis at L5-L6 using tricortical iliac autograft or tricortical iliac autograft + titanium particulate. Group 2 received iliac autograft at the initial surgery and were reoperated on after 8 weeks and treated with posterolateral arthrodesis exposure alone or titanium particulate. Postoperative analysis included serologic quantification of systemic cytokines. Postmortem microradiographic, immunocytochemical, and histopathologic assessment of the intertransverse fusion mass quantified the extent of osteolysis, local pro-inflammatory cytokines, osteoclasts, and inflammatory infiltrates. RESULTS: Serologic analysis of systemic cytokines indicated no significant differences in cytokine levels (P > 0.05) between the titanium or autograft treatments. Immunocytochemistry indicated increased levels of local cytokines (tumor necrosis factor-alpha) at the titanium-treated posterolateral arthrodesis sites at both time periods (P < 0.05). Osteoclast cell counts and regions of osteolytic resorption lacunas were higher in the titanium-treated versus autograft-alone groups (P < 0.05), and the extent of cellular apoptosis was markedly higher in the titanium-treated sites at both time intervals. Electron microscopy indicated definitive evidence of phagocytized titanium particles and foci of local, chronic, inflammatory changes in the titanium-treated sites. CONCLUSION: Titanium particulate debris introduced at the level of a spinal arthrodesis elicits a cytokine-mediated particulate-induced response favoring pro-inflammatory infiltrates, increased expression of intracellular tumor necrosis factor-alpha, increased osteoclastic activity, and cellular apoptosis. The presence of titanium particulate debris, secondary to motion between spinal implants, may serve as the impetus for late-onset inflammatory-infectious complications and long-term osteolysis of an established posterolateral fusion mass in the clinical setting.

Acid Phosphatase↗

The effect of spinal instrumentation particulate wear debris. an in vivo rabbit model and applied clinical study of retrieved instrumentation cases.

STUDY DESIGN: The current study was undertaken to determine if the presence of spinal instrumentation wear particulate debris deleteriously influences early osseointegration of posterolateral bone graft or disrupts an established posterolateral fusion mass. OBJECTIVES: Using an in vivo animal model, the first phase (basic science) of this study was to evaluate the effect(s) of titanium wear particulate on a posterolateral spinal arthrodesis based on serological, histological and immunocytochemical analyses. The second phase (clinical) was to perform the same analysis of soft tissue surrounding spinal instrumentation in 12 symptomatic clinical patients. SUMMARY OF BACKGROUND DATA: The effect of unintended wear particulate resulting from micromotion between the interconnection mechanisms in spinal instrumentation remains a clinical concern. METHODS: Thirty-four New Zealand White rabbits were randomized into two groups based on postoperative time periods of 2 months (Group 1, n=14) and 4 months (Group II, n=20). Group I underwent a posterolateral arthrodesis (PLF) at L5-L6 using tricortical iliac autograft or tricortical iliac autograft plus titanium particulate. Group 2 all received iliac autograft at the initial surgery and were reoperated on after 8 weeks and treated with PLF exposure alone or titanium particulate. Postoperative analysis included serological quantification of systemic cytokines. Postmortem microradiographic, immunocytochemical and histopathological assessment of the intertransverse fusion mass quantified the extent of osteolysis, local proinflammatory cytokines, osteoclasts and inflammatory infiltrates. Clinical aspect of study: Over the last 2 years, 12 patients more than 0.4 years after spinal instrumentation presented with painful paraspinal inflammation. At surgical exploration, the cultures were negative for infection and the surrounding soft tissue was examined for cytokine reactions. There was loosening of implants and osteolysis in the location of the wear debris in 8 of 12 patients. RESULTS: Basic science phase: serological analysis of systemic cytokines indicated no significant differences in cytokine levels (p>.05) between the titanium or autograft treatments. Immunocytochemistry indicated increased levels of local cytokines: TNF-alpha at the titanium-treated PLF sites at both time periods (p<.05). Osteoclast cell counts and regions of osteolytic resorption lacunae were higher in the titanium-treated versus autograft-alone groups (p<.05), and the extent of cellular apoptosis was markedly higher in the titanium-treated sites at both time intervals. Electron microscopy indicated definitive evidence of phagocytized titanium particles and foci of local, chronic inflammatory changes in the titanium-treated sites. Clinical aspect: Eleven of 12 clinical cases demonstrated elevated TNF-alpha levels and an increased osteoclastic response in the vicinity of wear debris caused by dry frictional wear particles of titanium or stainless steel. Osteolysis most commonly involved loose transverse connectors. Resection of the wear debris and surrounding fibroinflammatory glycocalyx resulted in resolution of clinical symptoms in all 12 cases. CONCLUSIONS: Titanium particulate debris introduced at the level of a spinal arthrodesis elicits a cytokine-mediated particulate-induced response favoring proinflammatory infiltrates, increased expression of intracellular TNF-alpha, increased osteoclastic activity and cellular apoptosis. This is the first basic scientific study and the first clinical study demonstrating associations of spinal instrumentation particulates wear debris and increased cytokines and increased osteoclastic activity. Osteolysis is the number one cause of failure of orthopedic implants in the appendicular skeleton. Spinal surgeons need to increase their awareness of this destructive process.

Acid Phosphatase↗