Investigation of using a power function as a cost function in inverse planning optimization.

The purpose of this paper is to investigate the use of a power function as a cost function in inverse planning optimization. The cost function for each structure is implemented as an exponential power function of the deviation between the resultant dose and prescribed or constrained dose. The total cost function for all structures is a summation of the cost function of every structure. When the exponents of all terms in the cost function are set to 2, the cost function becomes a classical quadratic cost function. An independent optimization module was developed and interfaced with a research treatment planning system from the University of North Carolina for dose calculation and display of results. Three clinical cases were tested for this study with various exponents set for tumor targets and sensitive structures. Treatment plans with these exponent settings were compared, using dose volume histograms. The results of our study demonstrated that using an exponent higher than 2 in the cost function for the target achieved better dose homogeneity than using an exponent of 2. An exponent higher than 2 for serial sensitive structures can effectively reduce the maximum dose. Varying the exponent from 2 to 4 resulted in the most effective changes in dose volume histograms while the change from 4 to 8 is less drastic, indicating a situation of saturation. In conclusion, using a power function with exponent greater than 2 as a cost function can effectively achieve homogeneous dose inside the target and/or minimize maximum dose to the critical structures.

Algorithms↗

Effects of the intensity levels and beam map resolutions on static IMRT plans.

In this study we focus on how the intensity level and multileaf collimator (MLC) resolution affect the quality of IMRT plans using the static MLC delivery technique. The planning process is based on a least-square dose-based quadratic function and uses a simulated annealing algorithm to sample the discrete variables. Three clinical cases are studied empirically: a medulloblastoma, a prostate, and an oropharyngeal carcinoma. The intensity levels used are 3, 5, 10, 20, and continuous; the map resolution varies from 0.15-1.5 cm, with the leaf width equal to the step size. The influence of these two parameters are studied by comparing the cost value and the cost of delivery time from a trade-off point of view. An "efficient frontier" is drawn by connecting the plans with the lowest cost value at any given resolutions. For each case, a practical delivery region is defined by doubling the delivery time needed at a normal setting (five levels, 1.0 cm). Within this region, the "efficient frontier" demonstrates that the plans with five intensity levels are the most efficient comparing with plans with higher levels. This is a confirmation of the conclusion from Keller-Reichenbecher et al. [Int. J. Radiat. Oncol., Biol., Phys. 45, 1315-1324 (1999)]. It indicates that to further improve the plan quality with the minimal cost of extra delivery time, the most economical way is to improve the resolution rather than using higher intensity levels.

Algorithms↗