PubMed Health⌕ Search

Biomedical subjects

Nan Guang Chen

Publications and source records attributed to Nan Guang Chen.

5 recordsLinked to original sources

Double-pass rotary mirror array for fast scanning optical delay line.

We have developed a fast scanning optical delay line based on a rotary mirror array. A double-pass configuration is adopted to optimize the fiber-optical coupling and thus minimize the amplitude modulation in the reflected light. The achieved scanning range is extended to over 3 mm. An additional Michelson interferometer is incorporated into the reference arm to achieve high delay repeatability. Such a device is ideal for real-time optical coherence tomography, optical Doppler tomography, and spectroscopic optical coherence tomography.

Computer-Aided Design↗

Utilizing optical tomography with ultrasound localization to image heterogeneous hemoglobin distribution in large breast cancers.

PURPOSE: Angiogenesis in advanced breast cancers is highly distorted and heterogeneous. Noninvasive imaging that can monitor angiogenesis may be invaluable initially for diagnosis and then for assessing tumor response to treatment. By combining ultrasound (US) and near-infrared (NIR) optical imaging, a reliable new technique has emerged for localizing and characterizing tumor angiogenesis within the breast. METHODS: This new technique employs a commercial US transducer coupled with an array of NIR optical fibers mounted on a hand-held probe. The US image is used for lesion localization and for guiding optical imaging reconstruction. Optical sensors are used for imaging tumor total hemoglobin distribution, which is directly related to tumor angiogenesis. RESULTS: Six large breast carcinomas were studied and microvessel density count was then performed on tissue samples obtained from these cancers. Two patients had locally advanced breast cancers and received neoadjuvant chemotherapy for 3 months. In one patient, before chemotherapy, the total hemoglobin distribution showed a high concentration at the cancer periphery; the distribution was later confined to the core area after 3 months of treatment. In another patient, as treatment progressed, the maximum hemoglobin concentration decreased from 255.3, to 147.5, to 76.9 micromol/l with an associated reduction in spatial extension. The other four patients had cancers of 2.0 to 3.0 cm in size and were imaged either at the time of core biopsy or definitive surgery. The histologic microvessel density counts from these tumor samples correlate to hemoglobin distributions with a correlation coefficient of 0.64 (P < .05). CONCLUSION: These initial results suggest that this new imaging technique may have great potential in imaging the heterogeneous vascular distribution of larger breast cancers in vivo and in monitoring treatment-related changes in angiogenesis during chemotherapy.

Adenocarcinoma↗

Simultaneous reconstruction of absorption and scattering maps with ultrasound localization: feasibility study using transmission geometry.

We report the experimental results of the simultaneous reconstruction of absorption and scattering coefficient maps with ultrasound localization. Near-infrared (NIR) data were obtained from frequency domain and dc systems with source and detector fibers configured in transmission geometry. High- or low-contrast targets located close to either the boundary or the center of the turbid medium were reconstructed by using NIR data only and NIR data with ultrasound localization. Results show that the mean reconstructed absorption coefficient and the spatial distribution of the absorption map have been improved significantly with ultrasound localization. The improvements in the mean scattering coefficient and the spatial distribution of the scattering coefficient are moderate. When both the absorption and the scattering coefficients are reconstructed the performance of the frequency-domain systemis much better than that of the dc system.

Algorithms↗

Time-resolved optical measurements with spread spectrum excitation.

We propose a novel method for measuring time-dependent optical quantities. A train of excitation pulses modulated by a pseudorandom bit sequence is used as the light source, and a cross-correlation scheme is used to retrieve the impulse response. Simulation results of the temporal point-spread function of a diffusive wave are provided, as well as experimental results of a fluorescence decay profile. It is demonstrated that our new time-resolved technique can lead to high signal-to-noise ratios and short data acquisition times. A fluorescence-time-dependent suppression process was also been discovered.

Journal Article↗

Portable near-infrared diffusive light imager for breast cancer detection.

We present a frequency-domain near-infrared optical tomography system designed for breast cancer detection, in conjunction with conventional ultrasound. It features fast optical switching, three-wavelength excitations, and avalanche photodiode as detectors. Laser diodes at 660, 780, and 830 nm are used as light sources and their outputs are distributed sequentially to one of nine source fibers. An equivalent 130-dB isolation between electrical signals from different source channels is achieved with the optical switches of very low crosstalk. Ten detection channels, each of which includes a silicon avalanche photodiode, detect diffusive photon density waves simultaneously. The dynamic range of an avalanche photodiode is about 20 to 30 dB higher than that of a photomultiplier tube, thus eliminating the need for multistep system gain control. The entire system is compact in size (<0.051 m(3)) and fast in data acquisition (less than 2 sec for a complete scan). Calibration and the clinical experiment results are presented in the paper.

Algorithms↗