PubMed Health⌕ Search

Biomedical subjects

Nan Li

Publications and source records attributed to Nan Li.

132 records · Page 8Linked to original sources

[A comparative study of digital colposcope and optical colposcope in the diagnosis of early lesions of uterine cervix].

OBJECTIVE: To evaluate the clinical value of domestically manufactured digital colposcope system (SLC-2000) in the detection of early cervical lesions. METHODS: During a follow-up study of patients in Xiangyuan county, Shanxi, a high risk area for cervical cancer, a digital colposcope and an optical colposcope were randomly used for diagnosis, with pathology as the gold standard. RESULTS: In 163 cervical biopsy specimens, 103 were diagnosed as chronic inflammation by histologic examination. Among 60 specimens which gave abnormal pathology, there were papilloma 1, cervical intra-epithelial neoplasia (CIN) I 37, CIN II 18 and CIN III 4. In 33 endocervical curettage specimens, 3 were pathologically positive. Comparing the digital and optical colposcope in diagnosing the positive lesions of > or = CIN I, the sensitivity of the former and latter were 83.3% and 95.0%, the difference without being statistically significant (P = 0.075). The specificity, positive predictive value, and accuracy of these two instruments were 61.2%, 21.4%, 55.6% and 41.3%, 69.3% 48.5%, with significant difference (P = 0.000, P = 0.035, and P = 0.000). In diagnosing > or = CIN II cervical lesions, these three results of the two instruments did not show any significant difference either. The negative predictive value of the digital and optical colposcope were 86.3% and 88.0%, also showing no significant difference (P = 0.075). CONCLUSION: The specificity, positive predictive value, and accuracy of the digital colposcope in diagnosing cervical lesions > or = CIN I are all superior to those of the traditional optical colposcope, even though the sensitivity of the latter is higher. There is no difference between the two instruments in diagnosing lesions > or = CIN II. Not only is domestic digital colposcope (SLC-2000) effective, but feasible and practical in the diagnosis, research and follow-up of cervical lesions.

Colposcopes↗

Brain iron uptake in hypotransferrinemic mice: influence of systemic iron status.

The relationship of the heterogeneity of iron concentrations in the brain with the regulation of iron uptake into specific brain regions remains unresolved. We used hypotransferrinemic mice and an iron-deficient or control diet to explore whether plasma transferrin (Tf), transferrin saturation, and plasma iron levels influence the uptake of (59)Fe and whether there was brain region specificity. Weaning wild-type (+/+) and heterozygotic mice (+/hpx), were sorted randomly to either a iron-deficient diet or a control iron diet for 8 weeks, whereas homozygous mice (hpx/hpx) ate the control diet for 8 weeks before (59)Fe uptake studies. Iron-deficient heterozygous and wild-type mice both had significantly greater plasma Tf levels (37.5 and 42.5 microM) than control mice had (heterozygous and wild-type controls were 20 and 32.5 microM) and far more than homozygous mice (<0.2 microM) had, thus providing five distinct levels of plasma Tf concentrations. After intravenous injection of (59)Fe, brains of iron-deficient wild-type mice took up significantly more (59)Fe (0.15% dose) compared to control wild-type mice (0.056%) at 2 hr, a treatment effect that persisted through 24 hr. In contrast, diet had no effect in heterozygous mice. Importantly, homozygous mice had equivalent uptake to other groups (0.089% dose) by 24 hr. Early brain radioactivity varied by regions (hypothalamus and prefrontal cortex approximately 10-18% brain uptake > cerebellum, pons, thalamus, and striatum approximately 7-12% > cortex, hippocampus, and substantia nigra approximately 6-8%). This distribution of radioactivity changed over 24 hr in the hypothalamus of heterozygous mice, homozygous mice, and iron-deficient wild-type mice. Homozygous mice also showed higher uptake (13-15%) in some regions (hypothalamus and cerebellum) than in other regions. In wild-type and heterozygous mice, (59)Fe uptake was inversely related to brain Tf and was independent of regional brain iron concentrations and plasma Tf levels or saturation. These experimental data suggest that brain iron uptake may be constitutive and independent of plasma Tf, transferrin saturation, or regional brain iron concentration. The proteins and mechanisms responsible for additional iron uptake into specific regions, or perhaps the redistribution are unclear though the data are supportive of a non-transferrin-bound iron uptake pathway.

Analysis of Variance↗

Development and applications of in-gel CNBr/tryptic digestion combined with mass spectrometry for the analysis of membrane proteins.

Hydrophobic membrane proteins often have complex functions and are thus of great interest. However, their analysis presents a challenge because they are not readily soluble in polar solvents and often undergo aggregation. We present a sequential CNBr and trypsin in-gel digestion method combined with mass spectrometry for membrane protein analysis. CNBr selectively cleaves methionine residues. But due to the low number of methionines in proteins, CNBr cleavage produces a small number of large peptide fragments with MWs typically >2000, which are difficult to extract from gel pieces. To produce a larger number of smaller peptides than that obtained by using CNBr alone, we demonstrate that trypsin can be used to further digest the sample in gel. The use of n-octyl glucoside (n-OG) to enhance the digestion efficiency and peptide recovery was also studied. We demonstrate that the sensitivity of this membrane protein identification method is in the tens of picomole regime, which is compatible to the Coomassie staining gel-spot visualization method, and is more sensitive than other techniques reported in the literature. This CNBr/trypsin in-gel digestion method is also found to be very reproducible and has been successfully applied for the analysis of complex protein mixtures extracted from biological samples. The results are presented from a study of the analysis of bacteriorhodopsin, nitrate reductase 1 gamma chain, and a complex protein mixture extracted from the endoplasmic recticulum membrane of mouse liver.

Animals↗

Liquid chromatography MALDI MS/MS for membrane proteome analysis.

Membrane proteins play critical roles in many biological functions and are often the molecular targets for drug discovery. However, their analysis presents a special challenge largely due to their highly hydrophobic nature. We present a surfactant-aided shotgun proteomics approach for membrane proteome analysis. In this approach, membrane proteins were solubilized and digested in the presence of SDS followed by newly developed auto-offline liquid chromatography/matrix-assisted laser desorption ionization (LC/MALDI) tandem MS analysis. Because of high tolerance of MALDI to SDS, one-dimensional (1D) LC separation can be combined with MALDI for direct analysis of protein digests containing SDS, without the need for extensive sample cleanup. In addition, the heated droplet interface used in LC/MALDI can work with high flow LC separations, allowing a relatively large amount of protein digest to be used for 1D LC/MALDI which facilitates the detection of low abundance proteins. The proteome identification results obtained by LC/MALDI are compared to the gel electrophoresis/MS method as well as the shotgun proteomics method using 2D LC/electrospray ionization MS. It is demonstrated that, while LC/MALDI provides more extensive proteome coverage compared to the other two methods, these three methods are complementary to each other and a combination of these methods should provide a more comprehensive membrane proteome analysis.

Chromatography, High Pressure Liquid↗

Simple and robust two-layer matrix/sample preparation method for MALDI MS/MS analysis of peptides.

Recent advances in MALDI MS/MS instrumentation allow a high degree of automation in the efficient detection of peptide fragment ions that can be used for protein identification. However, the performance of the technique is dependent on the MALDI sample preparation. We present a simple and robust two-layer sample preparation method tailored for sensitive and reproducible generation of MALDI MS/MS data. This method produces a strong and uniform crystal layer which allows acquisition of high quality MS/MS spectra over the entire sample surface area. Furthermore, due to its crystal strength, the matrix/sample layer can be washed extensively on target, enabling direct analysis of samples containing impurities, such as salts and surfactants. This method is demonstrated to be very useful in routine analysis of in-gel tryptic digests of silver-stained protein gel spots, without the need of desalting steps or hunting for "hot" spots. As an example, seven threonine-phosphorylated proteins involved in signal transduction in response to growth factor stimulation within the lipid raft fractions of the IMR5 neuroblastoma cells have been identified using differential gel display, in-gel digestion and MALDI MS/MS with the new two-layer sample preparation method. Some of these proteins have the functions of maintaining raft structure or cell signaling.

Cell Line, Tumor↗

Characterization of human tear proteome using multiple proteomic analysis techniques.

Tear proteome profiling may generate useful information for the understanding of the interaction between an eye and its contacting objects, such as a contact lens or a lens implant. This is important for designing improved eye-care devices and maintaining the health of an eye. Proteome profiles of tear fluids may also be used for disease diagnosis and prognosis. However, only a small volume of tear fluid (<5 microL) can be collected in a clinical laboratory under normal operational conditions, which makes proteome profiling a challenge. In this work we apply several proteomic analysis techniques, including gel-based and solution-based approaches with LC-ESI and LC-MALDI MS and MS/MS to gauge the relative merits of producing proteome profiles and to generate as broad a coverage of the tear proteome as possible from this small amount of sample. It is shown that a total of 54 proteins can be confidently identified using less than 5 microL of tear fluid. Of these, 44 proteins can be detected by LC-MALDI MS alone with a consumption of 2 microL of tear fluid. Furthermore, LC-MALDI can be used to determine post-translational modifications (PTMs), such as glycosylation and phosphorylation, without any sample enrichment or treatment. This work represents one of the most extensive proteome profiles (i.e., proteins identified and PTMs characterized) generated from tear fluids using clinically relevant amounts of sample.

Chromatography↗