PubMed Health⌕ Search

Biomedical subjects

Nanyin Zhang

Publications and source records attributed to Nanyin Zhang.

8 recordsLinked to original sources

Noninvasive and three-dimensional imaging of CMRO(2) in rats at 9.4 T: reproducibility test and normothermia/hypothermia comparison study.

Ability to image cerebral metabolic rate of oxygen (CMRO(2)) is essential for studying the fundamental role of oxidative metabolism in brain function and disease. We have demonstrated recently that three-dimensional (3D) CMRO(2) images can be obtained in the rat brain during a 2-min (17)O(2) inhalation using the (17)O MR spectroscopic imaging (MRSI) approach at high field. The feasibility for establishing a completely noninvasive approach for imaging CMRO(2) has also been demonstrated. In this study, we further explored the feasibility of (17)O MRSI approach for performing repeated CMRO(2) measurements within a short period of time and evaluated the reproducibility of the repeated measurements. Subsequently, we applied the (17)O MRSI approach to measure CMRO(2) and cerebral blood flow (CBF) values at two brain temperatures in the alpha-chloralose anesthetized rat brain at 9.4 T. Finally, we tested the validity of simplified model for noninvasively determining CMRO(2) in normothermic and hypothermic rat brain. The results show (i) an excellent reproducibility among repeated measurements of 3D CMRO(2) images under the same physiologic condition; (ii) a 44% decrease of CMRO(2) across the rat brain at mild hypothermic (32 degrees C) condition as compared with normothermic (37 degrees C) condition; and (iii) a close correlation between CMRO(2) and CBF within a relatively wide physiologic range. This study demonstrates the capability of (17)O MRSI approach for noninvasively imaging CMRO(2) and its changes caused by physiologic perturbation. This approach, thus, should provide a promising neuroimaging modality for studying oxidative metabolism and bioenergetics associated with brain functions and diseases.

Animals↗

Spatial resolution of EEG cortical source imaging revealed by localization of retinotopic organization in human primary visual cortex.

The aim of the present study is to investigate the spatial resolution of electroencephalography (EEG) cortical source imaging by localizing the retinotopic organization in the human primary visual cortex (V1). Retinotopic characteristics in V1 obtained from functional magnetic resonance imaging (fMRI) study were used as reference to assess the spatial resolution of EEG since fMRI can discriminate small changes in activation in visual field. It is well known that the activation of the early C1 component in the visual evoked potential (VEP) elicited by pattern onset stimuli coincides well with the activation in the striate cortex localized by fMRI. In the present experiments, we moved small circular checkerboard stimuli along horizontal meridian and compared the activations localized by EEG cortical source imaging with those from fMRI. Both fMRI and EEG cortical source imaging identified spatially correlated activity within V1 in each subject studied. The mean location error, between the fMRI-determined activation centers in V1 and the EEG source imaging activation peak estimated at equivalent C1 components (peak latency: 74.8+/-10.6 ms), was 7 mm (25% and 75% percentiles are 6.45 mm and 8.4 mm, respectively), which is less than the change in fMRI activation map by a 3 degrees visual field change (7.8 mm). Moreover, the source estimates at the earliest major VEP component showed statistically good correlation with those obtained by fMRI. The present results suggest that the spatial resolution of the EEG cortical source imaging can correctly discriminate cortical activation changes in V1 corresponding to less than 3 degrees visual field changes.

Adult↗

Functional cortical source imaging from simultaneously recorded ERP and fMRI.

Feasibility of continuously and simultaneously recording visual evoked potentials (VEPs) with fMRI was assessed by quantitatively comparing cortical source images by means of receiver operating characteristic (ROC) curve analysis. The averaged EEG source images coincided well with simultaneously acquired fMRI activations. Strong correlation was found between the cortical source images of VEPs recorded inside and outside the scanner. Application of fMRI prior information strengthened correlation between estimated source images as well as resulted in source estimates with higher spatial resolution. The present results demonstrate that reliable cortical source images can be acquired during simultaneous fMRI scanning and they may be used for multimodal functional source imaging studies.

Adult↗

A dynamic fMRI study of illusory double-flash effect on human visual cortex.

Functional MRI (fMRI) combined with the paired-stimuli paradigms (referred as dynamic fMRI) was used to study the "illusory double-flash" effect on brain activity in the human visual cortex. Three experiments were designed. The first two experiments aimed to examine the cross-modal neural interaction between the visual and auditory sensory systems caused by the illusory double-flash effect using combined auditory (beep sound) and visual (light flash) stimuli. The fMRI signal in the visual cortex was significantly increased in response to the illusory double flashes compared to the physical single flash when the inter-stimuli delay between the auditory and visual stimuli was 25 ms. This increase disappeared when the delay was prolonged to approximately 300 ms. These results reveal that the illusory double-flash effect can significantly affect the brain activity in the visual cortex, and the degree of this effect is dynamically sensitive to the inter-stimuli delay. The third experiment was to address the spatial differentiation of brain activation in the visual cortex in response to the illusory double-flash stimulation. It was found that the illusory double-flash effect in the human visual cortex is much stronger in the periphery than the fovea. This finding suggests that the periphery may be involved in high-level brain processing beyond the retinotopic visual perception. The behavioral measures conducted in this study indicate an excellent correlation between the fMRI results and behavioral performance. Finally, this work demonstrates a unique merit of fMRI for providing both temporal and spatial information regarding cross-modal neural interaction between different sensory systems.

Acoustic Stimulation↗

Influence of gradient acoustic noise on fMRI response in the human visual cortex.

A paired-stimuli paradigm combined with fMRI was utilized to study the effect of gradient acoustic noise on fMRI response in the human primary visual cortex (V1) in terms of the auditory-visual cross-modal neural interaction. The gradient noise generated during the fMRI acquisition was used as the primary stimulus, and a single flashing light was used as the secondary stimulus. An interstimulus interval (ISI) separated the two. Six tasks were designed with different ISIs ranging from 50 to 700 ms. Both BOLD signal intensity and the number of activated pixels in V1 were analyzed and examined, and they showed a significant reduction when the gradient noise preceded the flashing light by approximately 300 ms. These results indicate that the gradient acoustic noise generated during fMRI acquisitions does interfere with neural behavior and the BOLD signal in the human visual cortex. This interference is modulated by the delay between the gradient noise and visual stimulation, and it can be studied quantitatively when the stimulation paradigm is designed appropriately. This study provides evidence of the auditory-visual interaction during fMRI studies, and the results should have an impact on fMRI applications.

Acoustics↗

In vivo 17O NMR approaches for brain study at high field.

17O is the only stable oxygen isotope that can be detected by NMR. The quadrupolar moment of 17O spin (I = 5/2) can interact with local electric field gradients, resulting in extremely short T1 and T2 relaxation times which are in the range of several milliseconds. One unique NMR property of 17O spin is the independence of 17O relaxation times on the magnetic field strength, and this makes it possible to achieve a large sensitivity gain for in vivo 17O NMR applications at high fields. In vivo 17O NMR has two major applications for studying brain function and cerebral bioenergetics. The first application is to measure the cerebral blood flow (CBF) through monitoring the washout of inert H2 17O tracer in the brain tissue following an intravascular bolus injection of the 17O-labeled water. The second application, perhaps the most important one, is to determine the cerebral metabolic rate of oxygen utilization (CMRO2) through monitoring the dynamic changes of metabolically generated H2 17O from inhaled 17O-labeled oxygen gas in the brain tissue. One great merit of in vivo 17O NMR for the determination of CMRO2 is that only the metabolic H2 17O is detectable. This merit dramatically simplifies both CMRO2 measurement and quantification compared to other established methods. There are two major NMR approaches for monitoring H2 17O in vivo, namely direct approach by using 17O NMR detection (referred as direct in vivo 17O NMR approach) and indirect approach by using 1H NMR detection for measuring the changes in T2- or T1rho-weighted proton NMR signals caused by the 17O-1H scalar coupling and proton chemical exchange (referred as indirect in vivo 17O NMR approach). Both approaches are suitable for CBF measurements. However, recent studies indicated that the direct in vivo 17O NMR approach at high/ultrahigh fields appears to offer significant advantages for quantifying and imaging CMRO2. New developments have further demonstrated the feasibility for establishing a completely noninvasive in vivo 17O NMR approach for imaging CMRO2 in a rat brain during a brief 17O2 inhalation. This approach should be promising for studying the central role of oxidative metabolism in brain function and neurological diseases. Finally, the similar approach could potentially be applied to image CMRO2 noninvasively in human brain.

Animals↗

Simplified methods for calculating cerebral metabolic rate of oxygen based on 17O magnetic resonance spectroscopic imaging measurement during a short 17O2 inhalation.

It has recently been shown that 17O magnetic resonance (MR) spectroscopic imaging at ultrahigh fields provides a reliable method for measuring CMRO2 during a short period of 17O2 gas inhalation. The mathematical (or complete) model used in the 17O MR method for calculating CMRO2 requires simultaneous measurements of multiple parameters including the concentration of H2 17O produced in the brain tissue from inhaled 17O2 gas (Cb), CBF, and the input function for the H2 17O concentration in the feeding artery (Ca). Both invasive and noninvasive measurements are involved in determining all of these parameters. In this article, two simplified methods are proposed and validated for calculating CMRO2 based on 17O MR measurement(s); the first method requires the measurements of Cb and CBF, but not Ca, and the second method only requires a single noninvasive measurement of Cb. The simplified methods were used to calculate CMRO2 in anesthetized rat brain, and the results were compared with those obtained using the complete model. The results from this work show (1) the validity of the simplified methods for quantifying CMRO2, and (2) the feasibility for establishing a completely noninvasive 17O MR approach for imaging CMRO2 in vivo.

Animals↗

Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field.

A comprehensive technique was developed for using three-dimensional (17)O magnetic resonance spectroscopic imaging at 9.4T for rapidly imaging the cerebral metabolic rate of oxygen consumption (CMRO(2)) in the rat brain during a two-min inhalation of (17)O(2). The CMRO(2) value (2.19 +/- 0.14 micromol/g/min, n = 7) was determined in the rat anesthetized with alpha-chloralose by independent and concurrent (17)O NMR measurements of cerebral H(2)17O content, arterial input function, and cerebral perfusion. CMRO(2) values obtained were consistent with the literature results for similar conditions. Our results reveal that, because of its superior sensitivity at ultra-high fields, the (17)O magnetic resonance spectroscopic imaging approach is capable of detecting small dynamic changes of metabolic H(2)17O during a short inhalation of (17)O(2) gas, and ultimately, for imaging CMRO(2) in the small rat brain. This study provides a crucial step toward the goal of developing a robust and noninvasive (17)O NMR approach for imaging CMRO(2) in animal and human brains that can be used for studying the central role of oxidative metabolism in brain function under normal and diseased conditions, as well as for understanding the mechanisms underlying functional MRI.

Animals↗