PubMed Health⌕ Search

Biomedical subjects

Naoki Asakawa

Publications and source records attributed to Naoki Asakawa.

16 recordsLinked to original sources

Reduction of carry-over in column-switching HPLC/MS system with automated system washing procedure for highly sensitive direct analysis of donepezil in dog plasma.

To solve the problem of carry-over--a persistent chromatographic challenge for bioanalytical assays with highly sensitive detector such as a mass spectrometry (MS)--a new on-line sample pretreatment HPLC/MS system using a column-switching technique was established. This system was designed to reduce carry-over based on a hydrophobic interaction mechanism using a washing function (multi-mobile phase flow system), as well as to remove impurities on-line in a mobile phase for the pretreatment. As a result, a washing function in this system was enabled to reduce carry-over and to remove impurities in a mobile phase by automatic operation. Therefore, concentration levels of donepezil (DH) in dog plasma as low as 10 pg/mL could be determined using this on-line sample pretreatment HPLC/MS system. In addition, method validation results of specificity, linearity, accuracy, precision, lower limit of quantitation (LLOQ), and carry-over demonstrated that this on-line sample pretreatment HPLC/MS system was robust and valid as a practical assay of drugs and metabolites in the biological samples.

Animals↗

Sensitive determination of aspirin and its metabolites in plasma by LC-UV using on-line solid-phase extraction with methylcellulose-immobilized anion-exchange restricted access media.

We describe a sensitive determination of aspirin (ASA) and its three metabolites (salicylic acid [SA], 2,3-dihydroxybenzoic acid [2,3-DHBA], and 2,5-dihydroxybenzoic acid [gentisic acid (GA)]) in rat plasma. Analysis was carried out by on-line solid-phase extraction (SPE) using a methylcellulose-immobilized-strong anion-exchanger (MC-SAX), followed by liquid chromatography (LC) coupled with UV detection. The lower limits of quantitation for ASA and SA were 60 ng/mL in 100 microL of plasma, respectively. This method was validated with respect to intra- and inter-day precision, accuracy, and linearity up to concentrations of 20,000 ng/mL for ASA, SA, 2,3-DHBA and gentisic acid, respectively. The method was successfully applied to an analysis of the pharmacokinetics of ASA and SA in rats.

Animals↗

Reliable on-line sample preparation of basic compounds from plasma using a reversed phase restricted access media in column-switching LC.

We investigated on-line sample preparation of basic compounds from plasma using a methylcellulose-immobilized reversed-phase restricted-access media in column-switching liquid chromatography (LC). Dilution of the plasma sample with phosphate buffered saline prevented or delayed the formation of fibrin clots at 4 degrees C and resulted in reproducible on-line sample preparation over a 30-h period. The use of an ion-pair reagent in the extraction LC enhanced recoveries of hydrophilic basic compounds. The ability of the methods to quantify compounds in plasma were validated and the method was successfully applied to the pharmacokinetic study of a hydrophilic basic compound injected into the bloodstream of rats.

Acetonitriles↗

Simplified gradient generator for micro- and nano-liquid chromatography.

We have developed a simple device to generate gradient elution profiles using split tubing array (STAR) units for micro- and nano-HPLC. This gradient device consists of a delivery pump, a splitter, tubes in parallel, and a relatively large-volume mixing chamber. In the mixing chamber, an initially filled water-rich solvent is adjusted to an organic-rich solvent by delivery of appropriate components through the split paths, in which the flow rate and residence time are controlled by the sizes of the tubes employed. A program was developed to describe the output gradient profiles, and the predicted gradient profiles were highly consistent with the observed ones. A linear gradient generated by this STAR system was successfully applied to micro-HPLC systems for separation of digested peptides derived from serum albumin with sufficient reproducibility. Further miniaturization of STAR systems for nano-HPLC coupled with tandem mass spectrometry was accomplished to separate digested peptides from serum albumin with a reproducibility of retention times of better than 0.2%, and the obtained spectra from the well-separated chromatographic peaks allowed protein identification with high confidence by protein database searching. We believe that this simple and reproducible gradient system using an isocratic pump will be especially advantageous for nanoLC-MS, instead of flow-controlled gradient pumps.

Chromatography, High Pressure Liquid↗

Poly(epsilon-caprolactone)/chitin and poly(epsilon-caprolactone)/chitosan blend films with compositional gradients: fabrication and their biodegradability.

Poly(epsilon-caprolactone) (PCL)/chitin and PCL/chitosan blend films with compositional gradients were successfully fabricated by a dissolution/diffusion method; that is, repeatedly pouring the PCL/chitin (or PCL/chitosan) blend solutions, with variable composition, onto polysaccharide layers. The compositional gradient structure in the resulting films was characterized by polarized optic microscopy, ATR-FT-IR and trans-FT-IR microscopic spectroscopy. Enzymatic degradability of the PCL/chitin and PCL/chitosan blend films with compositional gradients in the presence of lysozyme was compared with those of homogeneous films and two-layer films. It was found that the degradation rate of PCL/chitin blend films with a compositional gradient was far lower than that of the neat chitin film, whereas the degradation rate of PCL/chitosan blend films with a compositional gradient was close to that of the neat chitosan film. The suppression of the chitosan crystallization, which accelerates the enzymatic degradation, at the surface of PCL/chitosan films with a compositional gradient was much more severe than that for PCL/chitin films with a compositional gradient.

Biodegradation, Environmental↗

Development of a large-volume, membrane-based injection system for gradient elution micro-liquid chromatography.

A membrane unit which can be used to inject a large volume of sample solution was developed to facilitate reproducible and accurate gradient elution in micro-high-performance liquid chromatography (micro-HPLC). Since the membrane unit has a very low void volume, it facilitates the effective concentration of analytes in large sample volumes. Gradient elution micro-HPLC with the membrane unit allowed the efficient separation of n-alkyl benzoates, used as test samples, in a short time without marked gradient delay. In this study, the membrane unit could be loaded with up to 50 microg of n-hexyl benzoate, and more than 500 microL of sample solution could be applied. In about 50 chromatographic runs, the relative standard deviation (RSD) of the relative retention time of n-hexyl benzoate with respect to methyl benzoate was 0.530%.

Benzoates↗

Effective on-line purification for cationic compounds in rat bile using a column-switching LC technique.

An on-line purification method for cationic compounds and their metabolites in rat bile was investigated using a column-switching technique. 8-Hydroxyquinoline and its glucuronide were used as test compounds. Bile samples were injected directly into the system and successful on-line extraction with high purification efficiency for analytes was achieved using two-dimensional extraction LC; that is, reversed-phase chromatography followed by cation-exchange chromatography. After removal of the endogenous component by extraction LC, chromatographic separation of the target analyte was performed on an analytical ODS column, followed by identification using UV detection. The quantitative ability of the method was evaluated on the basis of injection repeatability, linearity and accuracy. This novel method was also applied to LC/MS analysis in order to characterise the pharmacokinetics of propranolol in rats, and the metabolites were successfully identified.

Animals↗

On-line pretreatment using methylcellulose-immobilized cation-exchange restricted access media for direct liquid chromatography/mass spectrometric determination of basic drugs in plasma.

A novel methylcellulose-immobilized restricted access media column with strong cation-exchange groups on an internal surface (MC-SCX) was evaluated for the direct injection analysis of basic polar drugs in plasma by column-switching liquid chromatography/mass spectrometry (LC/MS). Analytical conditions, including an automated pretreatment step and MS detection, were optimized for a series of basic drugs (doxepin, desipramine, imipramine, nortriptyline, amitriptyline, clomipramine). On-line pretreatment with the MC-SCX column followed by fast gradient analysis using a C18 column resulted in a total analysis cycle time of 7 min for each spiked plasma sample. More than 150 plasma samples spiked with target compounds were measured without compromising MS detection (relative standard deviations less than 11% for all compounds, and regression coefficients greater than 0.99).

Animals↗

Novel methylcellulose-immobilized cation-exchange precolumn for on-line enrichment of cationic drugs in plasma.

We developed a novel methylcellulose-immobilized strong cation-exchange (MC-SCX) precolumn for direct analysis of drugs in plasma. MC-SCX consists of silica gel with a methylcellulose outer-surface and a 2-(4-sulfophenyl) ethyl phase inner-surface. The MC-SCX precolumn was evaluated by direct analysis using pyridoxine, atenolol and sulpiride spiked in plasma, using a column-switching HPLC system. Each drug was retained and enriched on MC-SCX using an acidic mobile phase, which resulted in good linearity, sufficient reproducibility, intra- and inter day precision, and accuracy in analytical ion-pair LC with trifluoroacetic acid. The analytical methods for model drugs were applied to pharmacokinetics of atenolol and sulpiride in rats.

Animals↗

Comonomer-unit compositions, physical properties and biodegradability of bacterial copolyhydroxyalkanoates.

The comonomer-unit compositions and their distribution of as-produced bacterial copolyesters, including poly(3-hydroxybutyrate-co-3-hydroxyvalerate), poly(3-hydroxy-butyrate-co-3-hydroxypropionate), poly(3-hydroxybutyrate-co-3-hydroxyhexanoate) and poly(3-hydroxybutyrate-co-4-hydroxybutyrate) are described in this paper. Each copolyester sample can be comonomer-unit compositionally fractionated into several fractions, indicating that the original copolymers are mixtures of copolymers with different comonomer-unit compositions. The effects of comonomer-unit compositional distribution on thermal properties, crystallization, biodegradability and solid-state phase behavior are investigated using comonomer compositionally fractionated copolymers.

Bacteria↗

Direct analysis of drugs in plasma by column-switching liquid chromatography-mass spectrometry using a methylcellulose-immobilized reversed-phase pretreatment column.

A novel methylcellulose-immobilized reversed-phase pretreatment column (MC-ODS) for column switching liquid chromatography-mass spectrometry (LC-MS) was investigated to improve recovery and durability. Pretreatment and analytical conditions were optimized so that high throughput and high selectivity was ensured during mass spectrometric analysis. Analytical runs, including deproteinization and gradient LC analysis, were conducted in a 6-min cycle. As a consequence, recoveries for test drugs (metoprolol, propranolol, lidocaine, dibucaine, bupivacaine) were greater than 90% and more than 300 plasma samples spiked with target compounds were directly injected and measured without compromising MS detection or system performance.

Acetonitriles↗

Isolation of a diterpenoid substance with potent neuroprotective activity from fetal calf serum.

Excess activation of glutamate receptors and production of free radicals including nitric oxide may result in severe and irreversible damage to the mammalian central nervous system (CNS), but endogenous defense systems that protect neurons from these insults are poorly understood. Here, we purified and isolated a neuroprotective substance, which has been named "serofendic acid," from a lipophilic fraction of FCS based on the ability to protect rat primary cortical neurons against nitric oxide cytotoxicity. Mass spectrometry and NMR spectroscopy revealed the chemical structure of serofendic acid (15-hydroxy-17-methylsulfinylatisan-19-oic acid) as a sulfur-containing atisane-type diterpenoid, which is unique among known endogenous substances. Synthetic serofendic acid exhibited potent protective actions on cortical neurons against cytotoxicity of a nitric oxide donor as well as of glutamate, although it did not show appreciable influences on glutamate receptor-mediated responses in these neurons. Electron spin resonance analysis demonstrated that serofendic acid had no direct scavenging activity on nitric oxide radicals but was capable of inhibiting the generation of hydroxyl radical, a presumed "executor" radical in the nitric oxide-mediated neurotoxic cascade. These findings suggest that serofendic acid is a low-molecular-weight bioactive factor that promotes survival of CNS neurons, probably through the attenuation of free radical-mediated insults.

Animals↗

Drug-plasma protein binding assay by electrokinetic chromatography-frontal analysis.

We developed a rapid, microscale and reliable analytical method for binding of drugs to plasma proteins using capillary electrophoresis (CE) with ionic cyclodextrins (CD) combined with frontal analysis. These CDs were used as pseudostationary phases of electrokinetic chromatography (EKC). The CD-modified EKC (CDEKC) approach allowed us to separate anionic drugs from plasma proteins, whereas CZE could not separate these drugs from plasma proteins because they had a similar mobility like plasma proteins. CDs uniquely interact with these drugs but not with plasma proteins. Therefore, CDEKC could be coupled with frontal analysis to measure the binding of anionic drugs to plasma proteins. The binding values obtained by CDEKC were highly consistent with those determined by the ultrafiltration method. Our CDEKC approach should expand the applicability of CE to protein binding analysis.

Blood Proteins↗

Improvement of dissolution and oral absorption of ER-34122, a poorly water-soluble dual 5-lipoxygenase/cyclooxygenase inhibitor with anti-inflammatory activity by preparing solid dispersion.

Several formulation approaches were attempted to improve the dissolution and the oral absorption of ER-34122, which is a novel dual 5-lipoxygenase/cyclooxygenase inhibitor with potent anti-inflammatory activity. The solid dispersion of ER-34122 with hydroxypropylmethylcellulose (TC-5RW), which is an inert solid carrier, resulted in a significant improvement in the dissolution rate of ER-34122. The solid dispersion was prepared by a solvent evaporation method using ethanol and water. The solid-state characteristics of the solid dispersion, the corresponding physical mixture, and ER-34122 alone were investigated by X-ray powder diffraction, Fourier transform infrared spectroscopy (FTIR), and an automated controlled-atmosphere microbalance. The X-ray powder diffraction patterns suggest that the solid dispersion exists in a totally amorphous state and the others exist in a crystalline state. The FTIR spectra results suggest that ER-34122 can interact with TC-5RW through intermolecular hydrogen bonding in the solid dispersion. This interaction may cause a stabilization of ER-34122 in the higher-energy, faster-dissolving amorphous state. The dissolution rate of ER-34122 from the solid dispersion was significantly greater than that from the physical mixture or the pure drug. Furthermore, when orally administrated to beagle dogs, ER-34122 showed about a 100-fold increase in both maximum concentration (C(max)) and area under the curve of concentration versus time (AUC) compared with the pure drug. Consequently, it was determined that the solid dispersion technique with TC-5RW provides a promising way to increase the dissolution rate and the oral absorption of poorly water-soluble drugs such as ER-34122.

Absorption↗

A rapid method for pKa determination of drugs using pressure-assisted capillary electrophoresis with photodiode array detection in drug discovery.

We developed a rapid screening method for determination of pK(a) of candidate drugs by pressure-assisted capillary electrophoresis (CE) coupled with a photodiode array detector. Application of pressure during CE analysis allowed completion of one CE run in less than 1 min, and the obtained pH-metric mobility shifts as well as pH-metric UV spectrum were analyzed by a nonlinear regression fitting software to determine pK(a) values. The difference between pK(a) values by this method and by other conventional methods is within 0.25 units for 82 ionic functional groups of 77 drugs. The pK(a) values of 96 compounds in dimethylsulfoxide solution on a 96-well microplate could be measured in 1 day. Our method provides rapid and accurate determination of pK(a) value.

Donepezil↗

Highly robust stainless steel tips as microelectrospray emitters.

Tapered stainless steel spray tips for sheathless microelectrospray ionization (microESI) have been developed. The fabrication procedure for the tapered stainless steel tips was optimized using an electropolishing technique followed by removal of the burr. Using the tip as the microESI emitter, a stable ESI spray was obtained at a flow rate of 20 nL/min. The sensitivity of the microESI system was almost two orders greater than that of the conventional ion spray system. The tip was highly stable, and was successfully used for over 1000 h. Moreover, these stainless steel tips were suitable for use with sheathless capillary electrophoresis/mass spectrometry (CE/MS) and capillary liquid chromatography/mass spectrometry (LC/MS) for routine analysis in proteomic and pharmaceutical applications.

Chromatography, Liquid↗