PubMed Health⌕ Search

Biomedical subjects

Naoko Inadama

Publications and source records attributed to Naoko Inadama.

3 recordsLinked to original sources

Transaxial system models for jPET-D4 image reconstruction.

A high-performance brain PET scanner, jPET-D4, which provides four-layer depth-of-interaction (DOI) information, is being developed to achieve not only high spatial resolution, but also high scanner sensitivity. One technical issue to be dealt with is the data dimensions which increase in proportion to the square of the number of DOI layers. It is, therefore, difficult to apply algebraic or statistical image reconstruction methods directly to DOI-PET, though they improve image quality through accurate system modelling. The process that requires the most computational time and storage space is the calculation of the huge number of system matrix elements. The DOI compression (DOIC) method, which we have previously proposed, reduces data dimensions by a factor of 1/5. In this paper, we propose a transaxial imaging system model optimized for jPET-D4 with the DOIC method. The proposed model assumes that detector response functions (DRFs) are uniform along line-of-responses (LORs). Then each element of the system matrix is calculated as the summed intersection lengths between a pixel and sub-LORs weighted by a value from the DRF look-up-table. 2D numerical simulation results showed that the proposed model cut the calculation time by a factor of several hundred while keeping image quality, compared with the accurate system model. A 3D image reconstruction with the on-the-fly calculation of the system matrix is within the practical limitations by incorporating the proposed model and the DOIC method with one-pass accelerated iterative methods.

Brain↗

[2D imaging simulations of a small animal PET scanner with DOI measurement: jPET-RD.].

We present a preliminary study on the design of a high sensitivity small animal DOI-PET scanner: jPET-RD (for Rodents with DOI detectors), which will contribute to molecular imaging. The 4-layer DOI block detector for the jPET-RD that consists of scintillation crystals (1.4 mm x 1.4 mm x 4.5 mm) and a flat panel position-sensitive photomultiplier tube (52 mm x 52 mm) was previously proposed. In this paper, we investigate imaging performance of the jPET-RD through numerical simulations. The scanner has a hexagonal geometry with a small diameter and a large axial aperture. Therefore DOI information is expected to improve resolution uniformity in the whole field of view (FOV). We simulate the scanner for various parameters of the number of DOI channels and the crystal length. Simulated data are reconstructed using the maximum likelihood expectation maximization with accurate system modeling. The trade-off results between background noise and spatial resolution show that only shortening the length of crystal does not improve the trade-off at all, and that 4-layer DOI information improves uniformity of spatial resolution in the whole FOV. Excellent performance of the jPET-RD can be expected based on the numerical simulation results.

Animals↗

[Computer simulation of DOI-PET detector (1) -analysis of DOI discrimination accuracy in a detector block-].

A detector proposed by Murayama et al. for detection of depth-of-interaction (DOI) in PET consists of three-dimensionally arranged crystal elements with proper optical reflectors and is coupled to an array of photomultiplier tubes. This detector has a great advantage in easiness and cost in fabrication. We implemented a simulator of this detector that allows us to find appropriate values of parameters such as optical properties of crystal or detector unit geometry before making detectors. The simulator is based on the Monte Carlo method that traces the migration of optical photons generated by interaction of a gamma ray with crystal. First, the simulator performance was validated by comparing with the experimental data obtained with some prototype detectors. Then, on some parameters including refractive index of inter-crystal material, reflectance of optical reflector and detector geometry, appropriate values were investigated for accurate discrimination of crystal element of interaction.

Computer Simulation↗