PubMed Health⌕ Search

Biomedical subjects

Narendra B Dahotre

Publications and source records attributed to Narendra B Dahotre.

5 recordsLinked to original sources

Corrosion degradation and prevention by surface modification of biometallic materials.

Metals, in addition to ceramics and polymers, are important class of materials considered for replacement of non-functional parts in the body. Stainless steel 316, titanium and titanium alloys, Co-Cr, and nitinol shape memory alloys are the most frequently used metallic materials. These alloys are prone to corrosion in various extents. This review briefly discusses the important biomaterials, their properties, and the physiological environment to which these materials are exposed. Corrosion performance of currently used metallic materials has been assessed and threat to the biocompatibility from corrosion products/metal ions is discussed. The possible preventive measures to improve corrosion resistance by surface modification and to increase the bioactivity of the metallic surfaces have also been discussed. Importance of the formation of oxide layers on the metal surface, another aspect of corrosion process, has been correlated with the host response. The gap areas and future direction of research are also outlined in the paper.

Alloys↗

Laser induced hierarchical calcium phosphate structures.

The surface properties of biomedical implant materials control the dynamic interactions at tissue-implant interfaces. At such interfaces, if the nanoscale features influence protein interactions, those of the microscale and mesoscale aid cell orientation and provide tissue integration, respectively. It seems imperative that the synthetic materials expected to replace natural hard tissues are engineered to mimic the complexity of their hierarchical assembly. However, the current surface engineering approaches are single scaled. It is demonstrated that using laser surface engineering a controlled multiscale surface can be synthesized for bioactive functions. A systematic organization of bioactive calcium phosphate coating with multiphase composition on Ti-alloy substrate ranging from nano- to mesoscale has been achieved by effectively controlling the thermo physical interactions during laser processing. The morphology of the coating consisted of a periodic arrangement of Ti-rich and Ca-P-deficient star-like phases uniformly distributed inside a Ca-P-rich self-assembled cellular structure with the presence of CaO, alpha-tricalcium phosphate, CaTiO(3), TiO(2) and Ti phase in the coating matrix. The cellular structures ranged in diameter from 2.5 microm to 10 microm as an assembly of cuboid shaped particles of dimensions of approximately 200 nm x 1 microm. The multiscale texture also included nanoscale particles that are the precursors for many of these phases. The rapid cooling associated with the laser processing resulted in formation, organization and controlling dimensions of the Ca-P-rich glassy phase into a micron scale cellular morphology and submicron scale clusters of CaTiO(3) phase inside the cellular structures. The self-assembly of the coating into multiscale structure was influenced by chemical and physical interactions among the multiphases that evolved during laser processing.

Biocompatible Materials↗

Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.

Laser surface melting (LSM) of Ti-6Al-4V is performed in argon to improve its properties, such as microstructure, corrosion, and wear for biomedical applications. Corrosion behavior is investigated by conducting electrochemical polarization experiments in simulated body fluid (Ringer's solution) at 37 C. Wear properties are evaluated in Ringer's solution using pin-on-disc apparatus at a slow speed. Untreated Ti-6Al-4V contains alpha+beta phase. After laser surface melting, it transforms to acicular alpha embedded in the prior beta matrix. Grain growth in the range of 65-89 microm with increase in laser power from 800 to 1500 W due to increase in associated temperature is observed. The hardness of as-laserprocessed Ti-6Al-4V alloy is more (275-297 HV) than that of the untreated alloy (254 HV). Passivation currents are significantly reduced to < 4.3 microA/cm2 after laser treatment compared to untreated Ti-6Al-4V (approximately 12 microA/cm2). The wear resistance of laser-treated Ti-6Al-4V in simulated body fluid is enhanced compared to that of the untreated one. It is the highest for the one that is processed at a laser power of 800 W. Typical micro-cutting features of abrasive wear is the prominent mechanism of wear in both untreated and as-laser-treated Ti-6Al-4V. Fragmentation of wear debris assisted by microcracking was responsible for mass loss during the wear of untreated Ti-6Al-4V in Ringer's solution.

Alloys↗

Laser induced multi-scale textured zirconia coating on Ti-6Al-4V.

A textured coating of zirconia on Ti-6Al-4V alloy was produced using pulsed laser based processing technique. Scanning electron microscope observations coupled with fractal analysis revealed the multi-scale nature of the textured coating. Both stylus based profilometric measurements and fractal analysis indicated non-linear nature of the relationship between laser processing speed at constant pulse frequency (10 kHz) and roughness of the textured coating. The textured coatings produced with all the three processing speeds (40, 160, 290 cm/min) were fractal over certain length scales. Processing at 40 cm/min resulted in structures that are fractal across a large number of length scales where as higher processing speeds resulted in fractality over fewer length scales. The processing speed influenced the zirconia content in the coating and the phase transformation within Ti-matrix of the coating. Within the coating, while zirconia content decreased the amount of retained beta-Ti increased with increase in processing speed. Such physical and chemical transformations are desired in a titanium bio-implant for effective contact with protein, cells and tissues at various length scales and its effective chemical performance in bio-environment.

Alloys↗

Review paper: surface modification for bioimplants: the role of laser surface engineering.

Often hard implants undergo detachment from the host tissue due to inadequate biocompatibility and poor osteointegration. Changing surface chemistry and physical topography of the surface influences biocompatibility. At present, the understanding of biocompatibility of both virgin and modified surfaces of bioimplant materials is limited and a great deal of research is being dedicated to this aspect. In view of this, the current review casts new light on research related to the surface modification of biomaterials, especially materials for prosthetic applications. A brief overview of the major surface modification techniques has been presented, followed by an in-depth discussion on laser surface modifications that have been explored so far along with those that hold tremendous potential for bioimplant applications.

Biocompatible Materials↗