PubMed Health⌕ Search

Biomedical subjects

Naresh C Bhavaraju

Publications and source records attributed to Naresh C Bhavaraju.

2 recordsLinked to original sources

Analog seizure detection and performance evaluation.

Epilepsy is the most prevalent neurological disorder affecting both adults and children. Over two-and-one-half million individuals in the United States have epilepsy and 25% of them do not respond to drugs. A significant focus of current research efforts is the development of a fully implantable device for real-time seizure detection and automated warning and blockage of seizures. The purpose of this paper is to describe and demonstrate the feasibility of incorporating a novel tool, the percentile tracking filter into a successful, validated seizure detection algorithm to create an analog seizure detection device. We demonstrate, in a small-scale study, that the performance of this analog implementation is statistically similar to a digital implementation of a previously described and successfully validated seizure digital algorithm. This analog implementation can be realized into an application specific integrated circuit that is suitable for a fully implantable device for seizure monitoring, warning and treatment, which is likely to consume very little power, a feature of practical value.

Algorithms↗

Automated seizure abatement in humans using electrical stimulation.

The need for novel, efficacious, antiseizure therapies is widely acknowledged. This study investigates in humans the feasibility, safety, and efficacy of high-frequency electrical stimulation (HFES; 100-500 Hz) triggered by automated seizure detections. Eight patients were enrolled in this study, which consisted of a control and an experimental phase. HFES was delivered directly to the epileptogenic zone (local closed-loop) in four patients and indirectly, through anterior thalami (remote closed-loop), to the other four patients for every other automated seizure detection made by a validated algorithm. Interphase (control vs experimental phase) and intraphase (stimulated vs nonstimulated) comparisons of clinical seizure rate and relative severity (clinical and electrographic) were performed, and differences were assessed using effect size. Patients were deemed "responders" if seizure rate was reduced by at least 50%; the remaining patients were deemed "nonresponders." All patients completed the study; rescue medications were not required. There were 1,491 HFESs (0.2% triggered after-discharges). Mean change in seizure rate in the local closed-loop group was -55.5% (-100 to +36.8%); three of four responders had a mean change of -86% (-100 to -58.8%). In the remote closed-loop, the mean change of seizure rate was -40.8% (-72.9 to +1.4%); two of four responders had a mean change of -74.3% (-75.6 to -72.9%). Mean effect size was zero in the local closed-loop (responders: beneficial and medium to large in magnitude) and negligible in the remote closed-loop group (responders: beneficial and medium to large). HFES effects on epileptogenic tissue were immediate and also outlasted the stimulation period. This study demonstrates the feasibility and short-term safety of automated HFES for seizure blockage, and also raises the possibility that it may be beneficial in pharmaco-resistant epilepsies.

Adolescent↗