PubMed Health⌕ Search

Biomedical subjects

Narinder P Sidhu

Publications and source records attributed to Narinder P Sidhu.

2 recordsLinked to original sources

The effects of intrafraction motion on dose homogeneity in a breast phantom with physical wedges, enhanced dynamic wedges, and ssIMRT.

PURPOSE: This study attempts to compare how breathing motion affects intact-breast cancer patients between three different treatment techniques and to determine the degree of improvement on dose homogeneity when implementing gating therapy. METHODS AND MATERIALS: A breast phantom and respiratory simulator were designed to simulate respiratory motion to a first-order approximation. Film was used as a dosimeter, and static dosimetry data were used as a control for comparison. Three velocities of the breast phantom were studied, and gating therapy was introduced for each data set. Dose area histograms (DAHs) were calculated for a breast and a "lung" planning target area (PTA), and Normalized Agreement Test (NAT) indices were calculated in reference to the static case. RESULTS: Deviations from the static case were highest if the collimator speed was of the same magnitude as the speed of the target. In general, gating therapy improved dose uniformity to the breast PTA by up to 14% and reduced dose to the "lung" PTA by up to 24%. With step-and-shoot intensity-modulated radiation therapy (ssIMRT), gating the beam may compromise dose coverage of the breast PTA if the timing interval of the gate is too large. Gating the beam decreased NAT indices by 9 for physical wedges, by 16 for enhanced dynamic wedges, and by 6 for ssIMRT. CONCLUSIONS: Both the phantom and respiratory simulator are adequate for showing differences in dose distributions for all three treatment modalities. Gating therapy improves dose homogeneity to the PTAs and decreases the dose delivered to areas below the posterior border of the beams.

Breast↗

A 3D technique for simulation of irregular electron treatment fields using a digital camera.

Cerrobend inserts, which define electron field apertures, are manufactured at our institution using perspex templates. Contours are reproduced manually on these templates at the simulator from the field outlines drawn on the skin or mask of a patient. A previously reported technique for simulation of electron treatment fields uses a digital camera to eliminate the need for such templates. However, avoidance of the image distortions introduced by non-flat surfaces on which the electron field outlines were drawn could only be achieved by limiting the application of this technique to surfaces which were flat or near flat. We present a technique that employs a digital camera and allows simulation of electron treatment fields contoured on an anatomical surface of an arbitrary three-dimensional (3D) shape, such as that of the neck, extremities, face, or breast. The procedure is fast, accurate, and easy to perform.

Computer Simulation↗