Characterization of benign and malignant solid breast masses: comparison of conventional US and tissue harmonic imaging.

PURPOSE: To prospectively compare the diagnostic performance of radiologists by using conventional ultrasonography (US) and tissue harmonic imaging for the differentiation of benign from malignant solid breast masses, with histologic results used as the reference standard. MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained from all patients. Images were obtained with conventional US and tissue harmonic imaging in 88 patients (age range, 25-67 years; mean age, 45 years) with 91 solid breast masses (30 cancers and 61 benign lesions) before excisional or needle biopsy. Three experienced radiologists, who did not perform the examinations, independently analyzed the US findings and provided a level of suspicion to indicate the probability of malignancy. Results were evaluated by using kappa statistics and receiver operating characteristic (ROC) analyses. RESULTS: Regarding the descriptions of US findings, echogenicity (kappa=0.205) was the most discordant between conventional US and tissue harmonic imaging, followed by margin (kappa=0.495), lesion boundary (kappa=0.495), calcifications (kappa=0.537), posterior acoustic transmission (kappa=0.546), echotexture (kappa=0.586), shape (kappa=0.591), and orientation (kappa=0.594). The area under the ROC curve (Az) for conventional US and tissue harmonic imaging was 0.84 and 0.79, respectively, for reader 1; 0.88 and 0.85, respectively, for reader 2; and 0.91 and 0.89, respectively, for reader 3. The overall Az value for the three readers was 0.88 for conventional US and 0.84 for tissue harmonic imaging (95% confidence interval: -0.0950, 0.1646; P=.595). CONCLUSION: The performance of the radiologists with respect to the characterization of solid breast masses as benign or malignant was not significantly improved with tissue harmonic imaging.

Adult↗

Lymph node metastasis: ultrasmall superparamagnetic iron oxide-enhanced MR imaging versus PET/CT in a rabbit model.

PURPOSE: To prospectively compare the diagnostic accuracy of ultrasmall superparamagnetic iron oxide (USPIO)-enhanced magnetic resonance (MR) imaging and integrated positron emission tomography-computed tomography (PET/CT) for the depiction of lymph node metastasis in an animal model, with histologic findings as the reference standard. MATERIALS AND METHODS: This experiment was approved by the local animal care committee. VX2 carcinoma was implanted into the thighs of 11 rabbits 4 weeks before the imaging study. T2- and T2*-weighted MR examinations were performed 24 hours after USPIO administration, followed by integrated PET/CT. USPIO-enhanced MR imaging and PET/CT analysis for the evaluation of the presence of metastasis in iliac lymph nodes were performed independently by two radiologists and two nuclear medicine physicians, respectively, without histopathologic knowledge. Results were evaluated by using receiver operating characteristic (ROC) analysis, and sensitivities and specificities were compared by using a Z test. RESULTS: Metastases were histopathologically confirmed in 22 of 62 iliac lymph nodes. USPIO-enhanced MR imaging showed a significantly greater area under the ROC curve than did PET/CT (0.984 vs 0.852; P=.023). The respective sensitivity and specificity for the detection of lymph node metastasis were 91% (20 of 22) and 95% (38 of 40) for USPIO-enhanced MR imaging and 64% (14 of 22) and 98% (39 of 40) for PET/CT. In terms of sensitivity, a significant difference was found between USPIO-enhanced MR imaging and PET/CT, particularly for nodal metastasis of less than 5 mm (86% [six of seven] vs 0% [zero of seven]; P=.031), whereas the specificity of the two imaging modalities was similar (P=.226). CONCLUSION: USPIO-enhanced MR imaging results in higher diagnostic accuracy for depicting lymph node metastasis than does PET/CT.

Animals↗

Differentiating benign from malignant solid breast masses: comparison of two-dimensional and three-dimensional US.

PURPOSE: To compare prospectively obtained static two-dimensional (2D) and three-dimensional (3D) ultrasonographic (US) images in the diagnostic performance of radiologists with respect to the differentiation of benign from malignant solid breast masses with histopathologic examination as the reference standard. MATERIALS AND METHODS: This study had institutional review board approval, and patient informed consent was obtained. Conventional 2D and 3D US images were obtained from 141 patients (age range, 25-71 years; mean age, 46 years) with 150 solid breast masses (60 cancers and 90 benign lesions) before excisonal or needle biopsy. Four radiologists who had not performed the examinations independently reviewed 2D US images and stored 3D US data and provided a level of suspicion concerning probability of malignancy. The sensitivity, specificity, and negative predictive values of 2D images were compared with those of 3D US images. RESULTS: For all readers, 3D US images were the same as or better than 2D US images in terms of sensitivity (100% vs 100% for reader 1; 100% vs 98% for reader 2; 98% vs 93% for reader 3; 93% vs 92% for reader 4), specificity (58% vs 56% for reader 1; 51% vs 46% for reader 2; 83% vs 72% for reader 3; 86% vs 84% for reader 4), and negative predictive values (100% vs 100% for reader 1; 100% vs 98% for reader 2; 99% vs 94% for reader 3; 95% vs 94% for reader 4). These differences, however, were not statistically significant (P > .05). CONCLUSION: The performance of the radiologists with respect to the characterization of solid breast masses with static 2D US images was similar to that with 3D US data.

Adult↗

Computer-aided detection in digital mammography: comparison of craniocaudal, mediolateral oblique, and mediolateral views.

PURPOSE: To retrospectively compare the sensitivity of a computer-aided detection (CAD) system for depicting breast cancer in three digital mammographic views. MATERIALS AND METHODS: This study was conducted with institutional review board approval; informed consent was waived. A commercially available CAD system was applied to the craniocaudal, mediolateral oblique, and mediolateral digital mammographic views of 83 women (mean age, 48 years; range, 30-66 years) with 83 histologically proved breast cancers. Findings were 59 masses and 41 microcalcifications (17 lesions showed both findings; 42 lesions, mass only; and 24 lesions, microcalcification only). The paired t test was used to analyze sensitivity of the CAD system for the detection of cancer in these three mammographic views and in combinations of the views. RESULTS: The sensitivities of the CAD system were 92% (76 of 83) in the craniocaudal view, 83% (69 of 83) in the mediolateral oblique view, and 86% (71 of 83) in the mediolateral view; the differences were not significant (P = .07-.62). Sensitivity increased to 96% (80 of 83) in the craniocaudal plus mediolateral oblique views and to 99% (82 of 83) in the craniocaudal plus mediolateral oblique plus mediolateral views. For masses, the sensitivity of the CAD system was 76% (45 of 59) in the craniocaudal view and 75% (44 of 59) in the mediolateral oblique view and increased to 93% (55 of 59) when mediolateral oblique and craniocaudal views were combined (P < .001). For microcalcifications, sensitivity was 98% (40 of 41) in the craniocaudal view and 95% (39 of 41) in the mediolateral oblique view, and this increased to 100% (41 of 41) when the mediolateral oblique and craniocaudal views were combined (P = .31). CONCLUSION: The sensitivities of the CAD system were not significantly different among these three digital mammographic views. Sensitivity for depicting masses was significantly increased (P < .001) when the craniocaudal view was added to the mediolateral oblique view.

Adult↗

A surgically confirmed case of breast sparganosis showing characteristic mammography and ultrasonography findings.

A case of breast sparganosis was confirmed by surgical excision of a worm (fragmented into 5 pieces) in a 59-year-old Korean woman suffering from a palpable mass in the left breast. Mammography and ultrasonography characteristically revealed the presence of several well-defined, isodense and hypoechoic tubular masses, in the upper quadrant of the left breast, each mass consisting of a continuous cord- or worm-like structure. During surgery, a long segment of an actively moving sparganum of Spirometra sp. and 4 small fragments of the same worm, giving a total length of 20.3 cm, were extracted from the upper outer quadrant of the left breast and the axillary region. The infection source remains unclear, because the patient denied ingesting any snake or frog meat or drinking untreated water.

Breast Diseases↗

Diffractive ultrasound in the evaluation of solid breast masses: preliminary results.

PURPOSE: We sought to evaluate diffractive ultrasound (US) in the characterization of solid breast masses. MATERIALS AND METHODS: Forty-eight patients with solid breast masses (24 malignant and 24 benign) observed at conventional US underwent targeted diffractive US before needle biopsy or surgery. The process of locating the lesion was performed with knowledge of the mammography and conventional US. On diffractive US, imaging features, including shape, brightness, echotexture, margin, and boundary echo were analyzed and odds ratio (OR) were calculated to show how the risk of malignancy was altered by the presence of a given finding. RESULTS: Of the 48 solid breast masses seen on conventional US, 46 (96%) were seen at diffractive US. Diffractive US features suggestive of malignancy were irregular shape (OR 11.5), sono-opacity (OR 204), spiculated margin (OR 17.0), and absent boundary echo (OR 11.5) or thick rim (OR 5.5), whereas those of benignancy were round shape (OR 0.03), sonotransmission (OR 0.07) or isodensity (OR 0.01), well-defined margin (OR 0.03), and thin capsule (OR 0.03; P < 0.05). CONCLUSION: The finding of a sono-opaque mass on diffractive US was highly sensitive for malignancy. Further improvement of diffractive US equipment is needed to increase image quality and to permit inclusion of the axillary tail and deep portions of the breast.

Adult↗

Differentiation of benign from malignant solid breast masses: conventional US versus spatial compound imaging.

PURPOSE: To compare prospectively the diagnostic performance of radiologists who used conventional ultrasonography (US) with that of radiologists who used spatial compound imaging for the differentiation of benign from malignant solid breast masses. MATERIALS AND METHODS: The study was approved by the institutional review board, and informed consent was obtained. Before excisional or needle biopsy was performed, conventional US and spatial compound images were obtained in 67 patients (age range, 25-67 years; mean age, 45 years) with 75 solid breast masses (21 cancers and 54 benign lesions). Three experienced radiologists who did not perform the examinations independently analyzed US findings and indicated the probability of malignancy. Results were evaluated with kappa statistics and receiver operating characteristic (ROC) analysis. RESULTS: For US findings, the presence of calcifications was the most discordant feature (kappa = 0.372) between conventional US and spatial compound imaging, followed by echotexture (kappa = 0.439), boundary echo (kappa = 0.496), orientation (kappa = 0.518), echogenicity (kappa = 0.523), shape (kappa = 0.526), margin (kappa = 0.569), and posterior acoustic transmission (kappa = 0.669). The area under the ROC curve for conventional US was 0.79 for reader 1, 0.88 for reader 2, and 0.82 for reader 3, and the area under the ROC curve for spatial compound imaging was 0.85 for reader 1, 0.88 for reader 2, and 0.89 for reader 3. The partial area index for conventional US was 0.29 for reader 1, 0.69 for reader 2, and 0.39 for reader 3, and the partial area index for spatial compound imaging was 0.29 for reader 1, 0.65 for reader 2, and 0.39 for reader 3. The difference between the diagnostic performances of the two techniques was not significant (P > .05). CONCLUSION: The performance of the radiologists with respect to the characterization of solid breast masses was not significantly improved with spatial compound imaging.

Adult↗

Characteristic imaging features of breast fibroadenomas in women given cyclosporin A after renal transplantation.

PURPOSE: This retrospective study was conducted to determine the characteristic imaging and histopathologic features of breast fibroadenomas in kidney-transplant recipients given chronic cyclosporin A immunosuppressive therapy after the transplantation and to compare these characteristics with those from a control group. METHODS: From January 1, 1990, through December 31, 1999, 486 women underwent renal transplantation at our institution. All patients subsequently received immunosuppressive therapy with cyclosporin A and prednisolone. Ten (2%) of these women had developed breast fibroadenomas during this chemotherapy. We compared the data obtained on this group's fibroadenomas with those obtained from those in the control group, which comprised 100 women with fibroadenomas but who had never undergone organ transplantation or immunosuppressive therapy. RESULTS: Twenty-two fibroadenomas developed in the 10 transplant recipients. Eight of those 10 had multiple lesions, and 7 were affected bilaterally. The mean diameter of the fibroadenomas was 4.2 +/- 2.5 cm. Mammographically, the lesions were round or oval high-density masses with well-circumscribed margins and no calcification or spiculation. Sonographically, the lesions were relatively highly echogenic and had a lower ratio of the longitudinal to the anteroposterior diameter (L /AP) than did those in the control group. Histopathologically, the features of these lesions were generally typical of fibroadenomas, but some were more typical of malignant lesions. Among the 100 control patients, 146 fibroadenomas developed; 33 women had multiple lesions, and 12 were affected bilaterally. Their fibroadenomas had a mean diameter of 2.1 +/- 1.5 cm, and the imaging features of these lesions were typical of fibroadenomas. CONCLUSIONS: The fibroadenomas that developed in kidney-transplant recipients given chronic cyclosporin A and prednisolone immunosuppressive therapy had a tendency to be multiple, bilateral, and larger than those that developed in the control patients. These fibroadenomas also exhibited some imaging features that differed from those of typical fibroadenomas that develop in women who have not undergone organ transplantation or immunosuppressive therapy.

Adolescent↗

The effect of supraclavicular lymph node irradiation upon the thyroid gland in the post-operative breast carcinoma patients.

To identify the effect of post-operative irradiation to the thyroid gland in patients with breast carcinoma. Seventy seven patients with partial or total mastectomized breast carcinoma who received routine irradiation therapy (Hockey stick method: supraclavicular, internal mammary lymph nodes, and chest wall irradiation with 5,040 rads, divided into 30 treatments) were reviewed in terms of their ipsilateral thyroid gland response. All patients had the bilateral thyroid sizes measured annually by ultrasonography before and after radiation therapy. In the one-year follow-up group (n=77), 32 patients (41.5%) demonstrated decreased ipsilateral thyroid gland size after Hockey Stick irradiation therapy (p=0.428), in the two-year follow-up group (n=37), 26 patients (70.3%) demonstrated decreased gland size after Hockey Stick irradiation (p=0.001), and in the three-year follow-up group (n=21), 15 patients (71.4%) showed a decreased thyroid gland size (p=0.005). Most the patients with breast carcinoma (32/77 at the one-year follow-up, 26/37 at the two-year follow-up, and 15/21 at the three-year follow-up) after post-operative Hockey Stick irradiation therapy showed reduced ipsilateral thyroid gland size. Routine en face treatment of the supraclavicular lymph nodes, using the Hockey Stick method, should be reconsidered.

Breast Neoplasms↗

Sclerosing lobular hyperplasia: sonographic pathologic correlation.

The objective was to evaluate the sonographic findings of sclerosing lobular hyperplasia (SLH) of the breast and to correlate the sonographic findings and the pathologic features. This study consisted of 9 patients with pathologically proven sclerosing lobular hyperplasia who had undergone a preoperative imaging study. We retrospectively reviewed 9 ultrasonograms and 6 mammograms. In each patient mammographic findings including, shape and margin, and ultrasonographic findings including the size, length-to-anteroposterior ratio, shape, margin, internal echo pattern, and the presence and location of internal echogenic septum, were evaluated. Histopathologic correlations focused on characteristic imaging findings. Of the 6 mammograms, 4 cases showed a lobular (3 of 6) or an oval shaped mass (1 of 6) with a partly obscured margin (4 of 6). The remaining 2 cases showed heterogeneously dense breast without visible mass. Ultrasonograms showed a lobular (5 of 9) or an oval (4 of 9) shaped mass with a circumscribed margin (9 of 9). The mean length/anteroposterior ratio was 1.98. Intratumoral echogenic septum was present in 8 cases. Six cases had a peripherally arising septum. Histopathologic review revealed that this septum was correlated to interlobular sclerosis. A peripherally arising intratumoral echogenic septum on ultrasonography seen in SLH might be explained by the interlobular sclerosis.

Adult↗

Ductographic findings of breast cancer.

Ductography has become the gold standard for the evaluation of patients exhibiting pathologic nipple discharges. In nine patients (age range, 29-67 years; median age, 51 years) with invasive (n=5) or intraductal (n=4) cancer, ductographic findings were recorded, then correlated with mammographic and sonographic findings. Common ductographic findings included complete ductal obstruction, multiple irregular filling defects in the nondilated peripheral ducts, ductal wall irregularities, periductal contrast extravasation, and ductal displacement. Faint microcalcifications or ill-defined masses, which were not opacified by contrast material, were often discovered adjacent to ductal abnormalities. Mammographically and sonographically occult diffusely spreading intraductal cancers often manifested as pathologic nipple discharge. In such cases, meticulous ductographic examinations and interpretations were crucial in order not to miss breast cancers.

Adult↗

Sonographically guided core biopsy of the breast: comparison of 14-gauge automated gun and 11-gauge directional vacuum-assisted biopsy methods.

OBJECTIVE: To compare the outcomes of 14-gauge automated biopsy and 11-gauge vacuum-assisted biopsy for the sonographically guided core biopsies of breast lesions. MATERIALS AND METHODS: We retrospectively reviewed all sonographically guided core biopsies performed from January 2002 to February 2004. The sonographically guided core biopsies were performed with using a 14-gauge automated gun on 562 breast lesions or with using an 11-gauge vacuum-assisted device on 417 lesions. The histologic findings were compared with the surgical, imaging and follow-up findings. The histologic underestimation rate, the repeat biopsy rate and the false negative rates were compared between the two groups. RESULTS: A repeat biopsy was performed on 49 benign lesions because of the core biopsy results of the high-risk lesions (n = 24), the imaging-histologic discordance (n = 5), and the imaging findings showing disease progression (n = 20). The total underestimation rates, according to the biopsy device, were 55% (12/22) for the 14-gauge automated gun biopsies and 36% (8/22) for the 11-gauge vacuum-assisted device (p = 0.226). The atypical ductal hyperplasia (ADH) underestimation (i.e., atypical ductal hyperplasia at core biopsy and carcinoma at surgery) was 58% (7/12) for the 14-gauge automated gun biopsies and 20% (1/5) for the 11-gauge vacuum-assisted biopsies. The ductal carcinoma in situ (DCIS) underestimation rate (i.e., ductal carcinoma in situ upon core biopsy and invasive carcinoma found at surgery) was 50% (5/10) for the 14-gauge automated gun biopsies and 41% (7/17) for the 11-gauge vacuum-assisted biopsies. The repeat biopsy rates were 6% (33/562) for the 14-gauge automated gun biopsies and 3.5% (16/417) for the 11-gauge vacuum-assisted biopsies. Only 5 (0.5%) of the 979 core biopsies were believed to have missed the malignant lesions. The false-negative rate was 3% (4 of 128 cancers) for the 14-gauge automated gun biopsies and 1% (1 of 69 cancers) for the 11-gauge vacuum-assisted biopsies. CONCLUSION: The outcomes of the sonographically guided core biopsies performed with the 11-gauge vacuum-assisted device were better than those outcomes of the biopsies performed with the 14-gauge automated gun in terms of underestimation, rebiopsy and the false negative rate, although these differences were not statistically significant.

Adolescent↗