PubMed Health⌕ Search

Biomedical subjects

Nathan W Levin

Publications and source records attributed to Nathan W Levin.

At least 19 recordsLinked to original sources

Breath ethane in dialysis patients and control subjects.

Oxidant stress may play a role in the accelerated pathology of patients on dialysis, especially in the development of cardiovascular disease, which is a frequent condition in end-stage renal disease (ESRD) patients. Measurement of hydrocarbons can be employed to assess oxidant stress since breath hydrocarbons have been directly traced to in vivo breakdown of lipid hydroperoxides. We undertook to measure ethane, a major breath hydrocarbon, in 15 control subjects, 13 patients on peritoneal dialysis (PD), and 35 patients on hemodialysis (HD). Within the HD group, we separately examined 12 diabetic and 23 nondiabetic patients. Breath samples were collected after patients had breathed purified air for 4 min, and ethane content was measured by GC and expressed as pmoles/kg-body weight-minute (pmol/kg-min). As the data for the hemodialysis patients appeared skewed, nonparametric statistical techniques were employed to analyze these data, which are reported as median and interquartile range (IQR). Ethane levels were similar in 15 control subjects (median, 2.50 pmol [1.38-3.30]/kg-min] and 13 PD patients (median, 2.51 pmol [1.57-3.17]/kg-min). Breath ethane was significantly elevated in a portion (18 of 35 patients, 52%) of the HD patients (median, 6.16 pmol [4.46-8.88]/kg-min) (p <.001 vs. control, Mann-Whitney U test). Two of the diabetic HD patients showed extremely high values of breath ethane. Breath ethane was not altered by a single hemodialysis session, suggesting that long-term metabolic processes contribute to its elevation. Measurement of breath ethane may provide insight into severity of oxidant stress and metabolic disturbances, and provide guidance for optimal therapy and prevention of pathology in patients on long-term hemodialysis.

Adult↗

Measurement of intraperitoneal volume by segmental bioimpedance analysis during peritoneal dialysis.

BACKGROUND: Currently, ultrafiltration during peritoneal dialysis is determined from direct measurement of weight differences between the initial filling and final draining volumes. A new technique based on segmental bioimpedance analysis (SBIA) has been developed to accurately measure intraperitoneal volume continuously during peritoneal dialysis. METHODS: Twenty-two peritoneal dialysis patients were studied in a supine position during peritoneal dialysis consisting of 4 tidal exchanges (TPD). For bioimpedance measurements, 4 electrodes were placed, 1 on each hand and foot, to inject an alternating current. Sensing electrodes were placed on the lower ribs and the buttocks on both sides of the body. Calibration of the SBIA method was performed by first filling a known volume of dialysate to establish the relationship between change in resistance and a known fluid volume in the peritoneal cavity. The increase of fluid volume in the peritoneal cavity during dwell time was considered to be equal to net ultrafiltration volume occurring during this period. These measurements were compared with those obtained by the difference in weight between the total filling and draining volumes. RESULTS: The change in intraperitoneal volumes measured by differences in weight (0.39 +/- 0.29 L) did not differ significantly from those established from SBIA (0.41 +/- 0.31 L). Bland-Altman analysis yielded limits of agreement of 0.12 L. CONCLUSION: The SBIA technique provides a continuous noninvasive approach to the measurement of changes in intraperitoneal fluid volume.

Adult↗

Impact of albumin synthesis rate and the acute phase response in the dual regulation of fibrinogen levels in hemodialysis patients.

BACKGROUND: Fibrinogen is a risk factor for cardiovascular disease. It also is an acute phase protein (APP) and its plasma concentration increases with inflammation. Fibrinogen synthesis correlates with albumin synthesis in nephrotic patients and in patients with an expanded plasma volume even when serum albumin is normal and there is no inflammatory disease. The relationships among albumin synthesis, the acute phase response and plasma fibrinogen levels in hemodialysis patients are unknown. METHODS: In 74 hemodialysis patients, albumin synthesis, plasma volume (PV) and acute phase proteins (APPs) C-reactive protein (CRP), alpha1 acid glycoprotein (alpha1 AG), ceruloplasmin (Cer), and interleukin 6 (IL-6) were measured in serum and fibrinogen in plasma, and the results analyzed by multiple regression analysis. CRP, IL-6, alpha1 AG, Cer and fibrinogen were measured monthly, which enabled us to determine whether changes in these APPs correlated with the levels of and variability in plasma fibrinogen over time using a longitudinal modeling approach. Length of follow-up for the 74 patients ranged from 3.25 to 67.5 months. RESULTS: Baseline fibrinogen (548.6 +/- 106. 4 mg/dL) was significantly greater than levels reported for normal adults and correlated positively with albumin synthesis (P < 0.001), age (P < 0.001) and log CRP (P = 0.002) and negatively with PV (P < 0.001). Longitudinally, fibrinogen varied positively with long-lived APPs, Cer and alpha1 AG, as well as the short-lived APP, CRP. CONCLUSION: Plasma fibrinogen concentration is high in HD patients and directly correlates with increased albumin synthesis rates and the serum levels of APPs. Fibrinogen levels also correlate negatively with PV. Fibrinogen levels vary over time in synchrony with levels of other long-lived APPs, supporting the hypothesis that fibrinogen is regulated in part as a component of the acute phase response and in part by factors that increase albumin synthesis.

Acute-Phase Reaction↗

Methods and reproducibility of measurement of resistivity in the calf using regional bioimpedance analysis.

UNLABELLED: The usefulness of regional bioimpedance analysis (RBIA) in determining the dry weight in dialysis patients is currently being investigated. The aim of this study was to evaluate the reproducibility of measurement of resistivity in the calf. METHODS: Twenty-five normal subjects and 10 patients undergoing regular hemodialysis were studied. Four electrodes inserted into a blood pressure cuff were placed on the calf. Bioimpedance was continuously measured over 3- to 5-min periods (Xitron Hydra). After a resting period of 1 min, cuff pressure was increased to above the systolic blood pressure (SBP) for a few seconds to expel excess ECF fluid and then deflated. The effect on recordings of moving the electrodes 2 cm higher and then 2 cm lower than the normal position was studied in 8 normal subjects. In a second study of reproducibility, post-dialysis measurements were made twice in 10 patients who maintained the same post-dialysis target weight throughout the study period. RESULTS: The mean resting resistivity rho(0) in normal subjects was 532.6 +/- 95 omega.cm rising to 583.9 +/- 99.7 omega.cm when cuff pressure was applied rho(p). The average values of rho(0) and rho(p) in patients post-dialysis were 489 +/- 74 and 537 +/- 77 respectively showing that there were no significant differences in rho(0) and rho(p) between normal subjects and patients post-dialysis. The mean values of change in resistivity when the electrodes were shifted between the lowest and highest positions on the calf were -3.66 +/- 4.45 and -1.44 +/- 3.82%, respectively. Repeat measurement of resistivity in patients post-dialysis varied by 2.04 +/- 2.29% while post-dialysis body weight varied by 0.17 +/- 0.47%. CONCLUSION: In this study, resistivity measurement by RBIA at the calf showed similar levels of fluid loading in patients post-dialysis as in normal subjects. This study also showed that change in electrode position resulted in a mean change in resistivity of <5% and repeated measurements showed a change in resistivity <3% while body weight changes were <0.2%. This technique appears to have an acceptable level of reproducibility for its application to the assessment of patient hydration.

Adult↗

Sorbents in acute renal failure and the systemic inflammatory response syndrome.

Renal replacement therapy in acute renal failure is currently focused on the use of modifications of dialysis (continuous arteriovenous hemofiltration and hemodiafiltration) to remove middle molecular weight toxins, consisting of small proteins, and cytokines involved in the systemic inflammatory response syndrome (SIRS). Conventional high-flux dialyzers are not efficient at removing these molecules, prompting the investigation of sorbents to augment or replace dialysis. Sorbents have been developed to modulate SIRS by targeting cytokines such as IL-1, IL-6, IL-10, IL-18 and TNF, among others. Extensive pre-clinical studies are underway to demonstrate the clinical utility and safety of either adding sorbent hemoadsorption devices to hemodialysis, or the use of such devices alone in SIRS, sepsis, acute renal failure, cardiopulmonary bypass and end-stage renal disease.

Acute Kidney Injury↗

Slow continuous intracorporeal plasmapheresis for acute fluid overload.

Intermittent dialysis is still the predominant treatment for acute or chronic renal insufficiency in the USA despite increasing evidence that slower and longer fluid management therapies are more beneficial to the patient. We have investigated the use of slow continuous intracorporeal plasmapheresis (SCIP) as a more efficient and hemodynamically stable alternative means of treating acute fluid overload. In this paper we discuss preliminary observations on the safety of SCIP catheter insertion, fluid removal, extraction and pathology in Yorkshire pigs. SCIP catheters removed plasma for extracorporeal plasma water removal without significant gross or histopathological changes. Blood chemistry and cell counts remained stable during therapy. Toxicological studies indicated no pyrogenicity, hemolysis, cytotoxicity, acute systemic toxicity, delayed-type hypersensitivity, or blood recalcification coagulation inhibition. Intracutaneous extracts caused only mild irritation. SCIP therapy appears to be safe for use in the removal of plasma and plasma water from experimental animals.

Acute Disease↗

A kinetic model of inorganic phosphorus mass balance in hemodialysis therapy.

BACKGROUND: There is growing evidence that inorganic phosphorus (iP) accumulation in tissues (dTiP/dt) is a risk factor for cardiac death in hemodialysis therapy (HD). The factors controlling iP mass balance in HD are dietary intake (GiP), removal by binders (JbiP) and removal by dialysis (JdiP). If iP accumulation is to be minimized, it will be necessary to regularly monitor and optimize GiP, JbiP and JdiP in individual patients. We have developed a kinetic model (iPKM) designed to monitor these three parameters of iP mass balance in individual patients and report here preliminary evaluation of the model in 23 HD patients. METHODS: GiP was calculated from PCR measured with urea kinetics; JdiP was calculated from the product of dialyzer plasma water clearance (K(pwiP)) and time average plasma iP concentration (TACiP) and treatment time (t); a new iP concentration parameter (nTAC(iP), the TACiP normalized to predialysis CoiP) was devised and shown to be a highly predictable function of the form nTAC(iP) = 1 - alpha(1 - exp[-betaK(pwiP). t/ViP]), where the coefficients alpha and beta are calculated for each patient from 2 measure values for nTAC(iP), K(pwiP).t/ViP early and late in dialysis; we measured 8-10 serial values for nTAC(iP), K(pwiP). t/ViP over a single dialysis in 23 patients; the expression derived for iP mass balance is DeltaTiP = 12(PCR) - [K(pwiP)(t) (N/7)][CoiP(1 - alpha(1 - exp[-beta(Kt/ViP)]))] - k(b).Nb. RESULTS: Calculated nTAC(iP) = 1.01(measured nTAC(iP)), r = 0.98, n = 213; calculated JdiP = 0.66(measured total dialysate iP) + 358, n = 23, r = 0.88, p < 0.001. Evaluation of 10 daily HD patients (DD) and 13 3 times weekly patients with the model predicted the number of binders required very well and showed that the much higher binder requirement observed in these DD patients was due to much higher NPCR (1.3 vs. 0.96). CONCLUSION: These results are very encouraging that it may be possible to monitor the individual effects of diet, dialysis and binders in HD and thus optimize these parameters of iP mass balance and reduce phosphate accumulation in tissues.

Death↗

Daily dialysis: the long and the short of it.

There is considerable enthusiasm for daily hemodialysis despite the increased time commitment required of patients because of reported improvements in patient well-being, appetite and blood pressure control. To date, this therapy has been largely empirical and has been defined primarily by treatment time (t) and categorized as short daily hemodialysis (SDHD) with t about 2 h and long nocturnal hemodialysis (LNHD) with t 8-9 h. It is the authors' view that studies comparing clinical outcome with SDHD and LNHD to conventional hemodialysis (CHD) must have dialysis dosage well defined if they are to provide generalizable results. There is a broad range and overlap in the magnitude of solute removal in reported studies of SDHD, LNHD and CHD, which is illustrated here through kinetic consideration of four solutes: (1) urea; (2) inorganic phosphorus (iP); (3) beta(2)-microglobulin (beta(2)M) and (4) Na/water. The following observations can be made: (1) Patient subjective reports of increased appetite and protein intake may correlate poorly with kinetic calculation of protein catabolic rate. (2) A model of iP mass balance was developed and indicates that iP removal with CHD is inadequate; current SDHD is also inadequate to highly excessive depending on the dose of dialysis. (3) beta(2)M removal with SDHD is virtually the same as reported for LNHD, reflecting major differences in dialyzer membranes used. (4) The decrease in predialysis overhydration is a predictable function of the number of dialyses per week and may be one of the most important benefits of more frequent dialysis. (5) The standard K(t)/V (stdK(t)/V) provides a uniform method of dose calculation but the therapy prescription should also include consideration of the other solutes evaluated above.

Day Care, Medical↗

Effect of dialysis dose and membrane flux in maintenance hemodialysis.

BACKGROUND: The effects of the dose of dialysis and the level of flux of the dialyzer membrane on mortality and morbidity among patients undergoing maintenance hemodialysis are uncertain. METHODS: We undertook a randomized clinical trial in 1846 patients undergoing thrice-weekly dialysis, using a two-by-two factorial design to assign patients randomly to a standard or high dose of dialysis and to a low-flux or high-flux dialyzer. RESULTS: In the standard-dose group, the mean (+/-SD) urea-reduction ratio was 66.3+/-2.5 percent, the single-pool Kt/V was 1.32+/-0.09, and the equilibrated Kt/V was 1.16+/-0.08; in the high-dose group, the values were 75.2+/-2.5 percent, 1.71+/-0.11, and 1.53+/-0.09, respectively. Flux, estimated on the basis of beta2-microglobulin clearance, was 3+/-7 ml per minute in the low-flux group and 34+/-11 ml per minute in the high-flux group. The primary outcome, death from any cause, was not significantly influenced by the dose or flux assignment: the relative risk of death in the high-dose group as compared with the standard-dose group was 0.96 (95 percent confidence interval, 0.84 to 1.10; P=0.53), and the relative risk of death in the high-flux group as compared with the low-flux group was 0.92 (95 percent confidence interval, 0.81 to 1.05; P=0.23). The main secondary outcomes (first hospitalization for cardiac causes or death from any cause, first hospitalization for infection or death from any cause, first 15 percent decrease in the serum albumin level or death from any cause, and all hospitalizations not related to vascular access) also did not differ significantly between either the dose groups or the flux groups. Possible benefits of the dose or flux interventions were suggested in two of seven prespecified subgroups of patients. CONCLUSIONS: Patients undergoing hemodialysis thrice weekly appear to have no major benefit from a higher dialysis dose than that recommended by current U.S. guidelines or from the use of a high-flux membrane.

Adult↗

Relationships among inflammation nutrition and physiologic mechanisms establishing albumin levels in hemodialysis patients.

BACKGROUND: Serum albumin concentration is a balance among its synthesis rate, fractional catabolic rate (FCR), distribution, dilution in the plasma pool and external loss. The physiologic bases for establishing the level of serum albumin in hemodialysis patients have not been defined despite the association of hypoalbuminemia with excess mortality. Albumin concentration is associated with the levels of several acute phase proteins (APPs), C-reactive protein (CRP), alpha1 acid glycoprotein (alpha1 AG), or ceruloplasmin, and with nutritional markers, such as normalized protein catabolic rate (nPCR). METHODS: To establish the relationship among parameters that regulate albumin levels and markers of nutrition and inflammation, we injected [125I]-albumin, into 64 hemodialysis patients enrolled in the HEMO study to measure albumin distribution, synthesis and FCR. These variables were related to the levels of acute phase proteins (APPs), nPCR, body mass index (BMI), external albumin loss as well as demographic variables. Albumin distribution, synthesis and FCR were calculated from kinetic modeling, as was the initial plasma volume (PV). Serum albumin, transferrin, CRP, ceruloplasmin and alpha1 AG were measured weekly. Dialysate was collected during one dialysis each week to measure albumin loss. Results were analyzed by multiple linear regression. RESULTS: Albumin concentration correlated with its synthesis rate and FCR, but not with PV or its distribution between the vascular and extravascular pools. Albumin concentration also correlated with nPCR and alpha1 AG. However, albumin synthesis was directly related most strongly to PV and BMI (or nPCR), but not to levels of APPs. By contrast, albumin FCR correlated positively with both alpha1 AG and ceruloplasmin. CONCLUSION: Albumin concentration in dialysis patients changes with inflammation and nutritional status through their effects on albumin catabolism and synthesis, respectively. Within the range of albumin levels in these patients, nutritional variables primarily affected albumin synthesis while inflammation caused hypoalbuminemia by increasing albumin FCR. Albumin synthesis also increased in proportion to PV. The result of this is that PV expansion does not contribute to hypoalbuminemia.

Adult↗

Relationship between volume status and blood pressure during chronic hemodialysis.

BACKGROUND: The relationship between volume status and blood pressure (BP) in chronic hemodialysis (HD) patients remains incompletely understood. Specifically, the effect of interdialytic fluid accumulation (or intradialytic fluid removal) on BP is controversial. METHODS: We determined the association of the intradialytic decrease in body weight (as an indicator of interdialytic fluid gain) and the intradialytic decrease in plasma volume (as an indicator of postdialysis volume status) with predialysis and postdialysis BP in a cross-sectional analysis of a subset of patients (N=468) from the Hemodialysis (HEMO) Study. Fifty-five percent of patients were female, 62% were black, 43% were diabetic and 72% were prescribed antihypertensive medications. Dry weight was defined as the postdialysis body weight below which the patient developed symptomatic hypotension or muscle cramps in the absence of edema. The intradialytic decrease in plasma volume was calculated from predialysis and postdialysis total plasma protein concentrations and was expressed as a percentage of the plasma volume at the beginning of HD. RESULTS: Predialysis systolic and diastolic BP values were 153.1 +/- 24.7 (mean +/- SD) and 81.7 +/- 14.8 mm Hg, respectively; postdialysis systolic and diastolic BP values were 136.6 +/- 22.7 and 73.9 +/- 13.6 mm Hg, respectively. As a result of HD, body weight was reduced by 3.1 +/- 1.3 kg and plasma volume was contracted by 10.1 +/- 9.5%. Multiple linear regression analyses showed that each kg reduction in body weight during HD was associated with a 2.95 mm Hg (P=0.004) and a 1.65 mm Hg (P=NS) higher predialysis and postdialysis systolic BP, respectively. In contrast, each 5% greater contraction of plasma volume during HD was associated with a 1.50 mm Hg (P=0.026) and a 2.56 mm Hg (P < 0.001) lower predialysis and postdialysis systolic BP, respectively. The effects of intradialytic decreases in body weight and plasma volume were greater on systolic BP than on diastolic BP. CONCLUSIONS: HD treatment generally reduces BP, and these reductions in BP are associated with intradialytic decreases in both body weight and plasma volume. The absolute predialysis and postdialysis BP levels are influenced differently by acute intradialytic decreases in body weight and acute intradialytic decreases in plasma volume; these parameters provide different information regarding volume status and may be dissociated from each other. Therefore, evaluation of volume status in chronic HD patients requires, at minimum, assessments of both interdialytic fluid accumulation (or the intradialytic decrease in body weight) and postdialysis volume overload.

Adult↗

Cost-quality trade-offs in dialysis care: a national survey of dialysis facility administrators.

Dialysis facilities face important trade-offs between cost and quality under constrained capitated reimbursement. How management at dialysis facilities makes decisions affecting cost and quality of care and views opportunities and threats is unknown. We conducted a national survey of dialysis facility administrators. We asked administrators what changes they would make in response to increases or decreases in reimbursement, their views on linking dialysis care payment to quality-of-care measures, and their views on providing patients with treatment options and outcomes information. One hundred fifty-seven of 280 dialysis facility administrators (56%) responded. If dialysis reimbursement were to increase by 20%, the five most common responses were to: improve patient education programs (62% of respondents), improve facility amenities (42%), purchase new equipment (30%), provide more money for staff salaries (28%), and increase number of nursing staff (21%). Conversely, if dialysis reimbursement were to decrease by 20%, the most common responses were to: limit staff salary (45% of respondents), decrease nursing staff (41%), not replace dialysis equipment (43%), increase dialyzer reuse (37%), and return less to investors (36%). Differences in rank order of responses were observed according to professional training of the administrator and profit status of the facility. Administrators uniformly believe that it is very acceptable to provide facility-specific outcomes data to the public, as well as information on modalities of treatment provided by facilities. However, administrators varied in their views regarding whether reimbursement should be based on quality by using a process-of-care measure, such as the average dose of dialysis, or an outcome-of-care measure, such as case-mix-adjusted mortality rates. We conclude that increases in facility reimbursement generally would be used by dialysis facility administrators for the benefit of patients, whereas decreases (or inflation erosion) in payment rates might compromise staffing. US dialysis administrators support sharing treatment options and outcomes information with patients, but appear to be ambivalent with regard to linking reimbursement to adequacy of dialysis or patient outcomes. These results have important implications regarding proposed changes in the US capitated dialysis payment rate and current efforts to empower consumers of dialysis care.

Adult↗

Heat accumulation with relative blood volume decrease.

BACKGROUND: Both hypovolemia and heat accumulation act as powerful perturbations of blood pressure control. In hemodialysis, hypovolemia and heat accumulation often develop simultaneously, and the question arises of whether and to what extent these perturbations are linked. METHODS: Heat accumulation was measured by the amount of thermal energy (E) removed from a patient during prescribed ultrafiltration under isothermic hemodialysis conditions, ie, constant patient temperature. Measurement and control of temperatures and thermal energies were performed using the blood temperature monitor. Relative blood volume (RBV) was measured using the blood volume monitor. RESULTS: Thirty-eight treatments were analyzed in 12 patients (3 women). During treatments lasting 189 +/- 28 minutes, 5.1% +/- 1.3% of postdialysis body weight were removed from patients by ultrafiltration at a mean rate of 1.1 +/- 0.3 L/h. Blood volumes decreased to 85% +/- 7% of initial values, and 229 +/- 106 kJ of E were removed from patients at a cooling rate (J) of 20 +/- 8 W, corresponding to 28% +/- 11% of estimated energy expenditure (H%). E, J, and H% significantly increased as RBV decreased (P < 0.05). Linear regression analysis between J and RBV showed that approximately 1 W had to be removed from the patient for each percentage of change in blood volume (J = -102.38 + 0.97* RBV; r2 = 0.63). CONCLUSION: Results show that the probability for the effect of heat stress during hemodialysis increases with ultrafiltration-induced blood volume changes. Temperature control is an important aspect of hemodialysis treatment.

Adaptation, Physiological↗

Serum markers of periodontal disease status and inflammation in hemodialysis patients.

BACKGROUND: Hemodialysis (HD) patients face a 25% annual mortality rate, with 50% of reported deaths attributed to cardiovascular disease. All-cause and cardiovascular mortality correlate with such acute-phase proteins as C-reactive protein (CRP). Hepatic CRP synthesis is upregulated by inflammation; however, elevated CRP values frequently are found in the absence of apparent infection or inflammation. Because destructive periodontal diseases have been associated with elevated CRP levels, we questioned whether destructive periodontal diseases could contribute to elevated CRP values in HD populations. METHODS: Sera from 86 consecutive dentate HD patients were assayed for levels of immunoglobulin G (IgG) antibody to six periodontal species by means of an enzyme-linked immunosorbent assay. RESULTS: CRP values for the subject population ranged from less than 6.9 to 159 mg/L (median, 8.2 mg/L). Univariate comparisons between subjects with or without elevated CRP levels (>10 mg/L) showed that CRP level elevation was associated significantly (P < 0.05) with greater doses of human recombinant erythropoietin and lower levels of hemoglobin, serum iron, transferrin saturation (TSat), albumin averaged over the 3 preceding months, total cholesterol, and triglycerides. Log serum IgG antibody levels to Porphyromonas gingivalis also were significantly greater in the group with elevated CRP levels (P = 0.013). Subsequent multivariate logistic regression showed that log serum antibody levels to P gingivalis remained significant (P = 0.02) after controlling for nonperiodontal sources of elevated CRP, hemoglobin, TSat, and triglyceride values. CONCLUSION: These results suggest that elevated levels of IgG antibody to bacterial species associated with destructive periodontal diseases are associated with elevated CRP values in HD populations.

Actinobacillus Infections↗

Online monitoring of cerebral hemodynamics during hemodialysis.

BACKGROUND: Several factors, including anemia, diabetes, and hypertension, potentially could disturb the cerebral autoregulation mechanism in hemodialysis (HD) patients. This study examined the effect of hemodynamic and rheological changes on mean cerebral blood flow (CBF) velocity (MV) during HD. METHODS: Continuous online monitoring of MV and pulsatility index in the middle cerebral artery were performed in 18 HD patients by transcranial Doppler ultrasound during the entire HD period (range, 3 to 4 hours). In addition, blood pressure, hematocrit (Hct), and relative decrease in blood volume were continuously monitored. Blood samples were obtained at the beginning and end of HD to measure hemorheological variables. RESULTS: After HD, Hct increased significantly from 33.6% +/- 5.9% to 41.4% +/- 5.7% (P < 0.001). Blood and plasma viscosity increased significantly from 3.33 +/- 0.77 to 4.36 +/- 1.3 mPa.s (P < 0.001) and from 1.35 +/- 0.29 to 1.54 +/- 0.38 mPa.s (P < 0.001), respectively. The change in MV (DeltaMV) was not significantly different from zero and correlated significantly with change in Hct. During HD, mean arterial pressure (MAP) in 15 patients changed within the normal range (group I), whereas 3 patients developed hypotension (group II) and their MAP decreased from 99 +/- 5 to 60 +/- 8 mm Hg (P < 0.05). In both groups, DeltaMV were not significant. CONCLUSION: Results of this study suggest that CBF does not appear to be diminished significantly during HD.

Aged↗

The Acute Dialysis Quality Initiative--part IV: membranes for CRRT.

The extracorporeal membrane used in a continuous renal replacement therapy (CRRT) for the treatment of a critically ill patient with acute renal failure (ARF) is vitally important for several reasons, including its influence on biocompatibility and filter performance. The clinical relevance of membrane-related biocompatibility markers traditionally used in chronic hemodialysis remains unclear in CRRT. Numerous approaches may be used to assess membrane and filter performance in CRRT, but no specific methodology is accepted widely at present. Although a potential benefit of certain membranes used for CRRT is adsorptive removal of inflammatory mediators, this issue has not been assessed carefully in well-designed clinical trials. These and other issues should be the subject of future clinical research efforts.

Acute Kidney Injury↗