At least 55 records · Page 3Linked to original sources

Retinal embolization of bicuspid aortic valve calcification.

We report the case of a 36-year-old man with calcified bicuspid aorta. Aortic disease was diagnosed after retinal embolism, which caused loss of vision affecting the left eye. Doppler examination did not identify carotid stenosis. Transthoracic echocardiography showed thickness and calcification of two leaflets, moderate aortic regurgitation, high normal left ventricular diastolic dimensions, and high normal interventricular septum thickness. Parasternal long-axis view in the systolic frame showed dilated left ventricular outflow tract, dilated ascending aorta, and calcification and thickening of aortic leaflets, causing an echo-lucent area, in the diastolic frame. It also showed the eccentric position of the closed valve leaflets, short axis in the diastolic frame, and the absence of the typical "Y" letter sign, tracked by the three leaflets (septal, right coronary, and left coronary) in the normal tricuspid aortic valve. On long-axis parasternal acquisition, we note high normal interventricular septum thickness and high normal diastolic diameter. Color Doppler analysis from the apical five-chamber view showed aortic regurgitation; regurgitant jet area was about 44% of the outflow tract, so aortic regurgitation was classified as moderate. Pulsed Doppler showed a high normal value of peak aortic velocity. Transesophageal echocardiography was performed, but no further findings were identified. We think that the likely retinal embolism sources were the aortic calcified leaflets, even if the aortic valve was not stenotic and with no signs of endocarditis. However, because we cannot exclude other potential causes, we put the patient on anticoagulant therapy. Furthermore, aortic valve replacement was not advised.

Adult↗

Definitive diagnosis of cor triatriatum with common atrium by three-dimensional transesophageal echocardiography in an adult.

We describe an adult patient, in whom three-dimensional transesophageal echocardiography was able to make a definitive diagnosis of cor triatriatum associated with common atrium. The lesion mimicked a classical partial atrio-ventricular septal defect on both transthoracic and transesophageal two-dimensional echocardiography. We found only two cases in the literature describing the existence of cor triatriatum with common atrium, none diagnosed by echocardiography.

Cor Triatriatum↗

Transpharyngeal ultrasound detection of carotid body paraganglioma.

We report a patient in whom a right carotid body paraganglioma was delineated using a transpharyngeal approach during a transesophageal echocardiographic (TEE) study. Color Doppler-guided pulsed-Doppler interrogation of the right internal carotid artery in the tumor region, revealed high maximum systolic and maximum diastolic velocities of 1.5 m/s and 1.0 m/s, respectively, suggestive of tumor compression.

Carotid Artery, Internal↗

Transesophageal and transpharyngeal ultrasound demonstration of reversed diastolic flow in aortic arch branches and neck vessels in severe aortic regurgitation.

In the current study, we describe an adult patient with torrential aortic regurgitation due to an aortic dissection flap interfering with aortic cusp motion, in whom a transesophageal echocardiogram with the probe positioned in the upper esophagus and transpharyngeal ultrasound examination demonstrated prominent reversed flow throughout diastole in the left subclavian, left vertebral, left common carotid, and left internal carotid arteries. Another unique finding was the demonstration of aortic valve leaflets held in the fully opened position in diastole by the dissection flap as it prolapsed into the left ventricular outflow tract, dramatically documenting the mechanism of torrential aortic regurgitation in this patient.

Aortic Dissection↗

Live three-dimensional transthoracic echocardiographic assessment of anomalous origin of left coronary artery from the pulmonary artery.

We describe live three-dimensional transthoracic echocardiographic (3DTTE) findings in a 52-year-old female who had previously undergone an aortopulmonary tunnel operation for anomalous origin of the left coronary artery (ACA) from the pulmonary artery. Three-dimensional transthoracic echocardiography clearly delineated the origin of the ACA from the posterolateral aspect of the main pulmonary artery just above the pulmonary valve, the surgically created tunnel, as well as a small defect in the tunnel near the aortic end communicating with the pulmonary artery.

Abnormalities, Multiple↗

Live three-dimensional transthoracic echocardiographic assessment of left ventricular hydatid cyst.

We report an adult patient in whom live three-dimensional transthoracic echocardiography (3DTTE) complemented two-dimensional transthoracic echocardiography (2DTTE) in making a definitive diagnosis of a hydatid cyst located in the left ventricular cavity. The parent hydatid cyst, as well as the daughter cysts, contained within it could be delineated by both 2DTTE and live 3DTTE. However, the tertiary or granddaughter cysts originating from the daughter cysts as well as great-granddaughter cysts budding from tertiary cysts could be visualized only when the live 3DTTE data sets were cropped and sectioned sequentially using multiple cutting planes. In addition, apparent intrinsic mobility of some of the tertiary cysts implying viability was detected only by 3DTTE.

Adult↗

Morphological assessment of left ventricular thrombus by live three-dimensional transthoracic echocardiography.

We report the usefulness of live three-dimensional transthoracic echocardiography (3DTTE) in the morphological assessment of a left ventricular thrombus. Using live 3DTTE, the thrombus could be easily viewed end-on and from the sides. In addition, by cropping the 3D images sequentially in transverse (horizontal or short axis), longitudinal (vertical or long axis), frontal, and oblique planes, the degree and extent of lysis within the thrombus, which represents an integral part of the clot-resolution process, could be comprehensively assessed. The site of attachment of the thrombus in the left ventricular apex and its morphology could also be fully evaluated in three dimensions by live 3DTTE.

Adult↗

Usefulness of live three-dimensional transthoracic echocardiography in the characterization of atrial septal defects in adults.

In this report we present 12 adult patients in whom surgical or percutaneous intervention was considered for repair of atrial septal defect (ASD). Location, size, and surrounding atrial anatomy of the ASD were assessed prior to intervention in all patients with standard and live three-dimensional transthoracic echocardiography (3D TTE). In the four patients in whom intraoperative three-dimensional transesophageal echocardiographic reconstruction (3D TEE) was done, 3D TTE measurements of maximum dimension, maximum circumference, and maximum area of ASD agreed well with 3D TEE. In the seven patients who underwent transcatheter closure device insertion, live 3D TTE measurements of maximum dimension, maximum circumference, and maximum area of ASD agreed well with the sizing balloon. Additionally, since the sizing balloon measures a stretched diameter and area, a live 3D TTE stretched ASD diameter and area (derived from the actual live 3D TTE maximum circumference) were calculated and demonstrated improved agreement with the sizing balloon measurements. In all patients, > or =5 mm of atrial tissue was visualized surrounding the ASD. Further, with the addition of contrast enhancement, characterization of a small patent foramen ovale (<5 mm) was possible in one patient. Live 3D TTE accurately defined ASD location, size, and surrounding atrial anatomy in all patients studied by us. ASD characterization by live 3D TTE agreed well with 3D TEE and sizing balloon measurements.

Adolescent↗

Quantification of mitral regurgitation by live three-dimensional transthoracic echocardiographic measurements of vena contracta area.

We evaluated 44 consecutive patients who underwent standard two-dimensional (2D) and live three-dimensional (3D) transthoracic echocardiography (TTE), as well as left heart catheterization with left ventriculography. Mitral regurgitant vena contracta area (VCA) was obtained by 3D TTE by systematic and sequential cropping of the acquired 3D TTE data set. Assessment of mitral regurgitation (MR) by ventriculography was compared to measurements of VCA by 3D TTE and to 2D TTE measurements of MR jet area to left atrial area (RJA/LAA), RJA alone, vena contracta width (VCW), and calculated VCA. VCA from 3D TTE closely correlated with angiographic grading (rs=0.88) with very little overlap. VCA of <0.2 cm2 correlated with mild MR, 0.2-0.4 cm2 with moderate MR, and >0.4 cm2 with severe MR by angiography. Ventriculographic grading also correlated well with 2D TTE measurements of RJA/LAA (rs=0.79) and RJA alone (rs=0.76) but with more overlap. Assessment of VCW and calculated VCA by 2D TTE agreed least with ventriculography (rs=0.51 and rs=0.55, respectively). Live 3D TTE color Doppler measurements of VCA can be used for quantitative assessment of MR and is comparable to assessment by ventriculography.

Adult↗

Real-time three-dimensional myocardial contrast echocardiography in assessment of myocardial perfusion defects.

BACKGROUND: Both real-time three-dimensional echocardiography (RT3DE) and myocardial contrast echocardiography (MCE) are novel imaging techniques. The purpose of this study was to confirm the feasibility and accuracy of RT3DE combined with MCE for quantitative evaluation of myocardial perfusion defects. METHODS: Thirteen dogs underwent ligation of the left anterior descending artery (LAD, n = 6) or distal branch of the left circumflex artery (LCX, n = 7) under general anaesthesia. Three to four ml of a perfluoropropane (C3F8) microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with a commercially available Philips SONOS-7500 ultrasound system. After removal of the dog hearts, Evans blue dye was injected via the left and right coronary arteries to stain the myocardium at risk. In vitro anatomic measurements of myocardial mass after removal of the animals' hearts were used as controls. RESULTS: Left ventricular (LV) mass determined by RT3DE ranged 36.7 - 68.9 g [mean, (54.6 +/- 9.6) g] before coronary artery ligation, and correlated highly (r = 0.99) with in vitro measurement of LV mass [range, 38.9 - 71.1 g; mean, (55.6 +/- 9.3) g]. There was no significant difference between RT3DE and in vitro measurements of LV mass [range, 36.7 - 68.9 g; mean, (51.3 +/- 12.5) g. Or range, 38.9 - 71.1 g; mean, (53.7 +/- 12.3) g, respectively] and under-perfused mass [range, 0 - 21.4 g; mean, (12.0 +/- 6.9) g. Or range, 0 - 19.8 g; mean, (10.8 +/- 6.3) g, respectively] after the LAD ligation (P > 0.05). Likewise, no significant difference was present between RT3DE and in vitro measurements of LV mass [range, 50.1 - 65.4 g; mean, (57.5 +/- 5.9) g. Or range, 51.5 - 65.8 g; mean, (57.3 +/- 6.4) g, respectively] and under-perfused mass [range, 0 - 25.6 g; mean, (13.3 +/- 9.6) g. Or range, 0 - 22.7 g; mean, (12.8 +/- 8.1) g, respectively] after the LCX ligation (P > 0.05). For all the animals with coronary ligation, LV mass measured by RT3DE ranged 35.9 - 68.6 g [mean, (54.8 +/- 10.0) g] and there was no significant difference between RT3DE and in vitro measurements of LV mass and under-perfused mass (P > 0.05, r = 0.99). Further, the under-perfused mass derived from RT3DE [range, 0 - 25.6 g; mean, (12.7 +/- 8.2) g] correlated strongly with the in vitro measurements [range, 0 - 22.7 g; mean, (11.9 +/- 7.2) g] (r = 0.96). CONCLUSION: RT3DE with MCE is a rapid and accurate method for estimating LV myocardial mass and quantifying perfusion defects.

Animals↗

Hemodynamic evaluation of normally functioning Sulzer Carbomedics prosthetic valves.

The Sulzer Carbomedics prosthetic heart valve (CP) is a commonly used mechanical valve in clinical practice. In the present study, we used conventional and color Doppler echocardiography to assess the hemodynamics of normally functioning CP in the aortic (n = 73) and mitral (n = 127) positions. Our findings demonstrate no significant correlation of Doppler-measured peak and mean pressure gradients and effective orifice area with implanted valve size and actual orifice areas, measured directly by the manufacturer for CPs in both the mitral and aortic positions. However, it is still useful to measure effective orifice area by Doppler because a value in the normal or nonstenotic range points to an unobstructed prosthesis in the aortic or mitral position, in the absence of poor left ventricular ejection fraction. A value in the stenotic range could mean a normally functioning or obstructed prosthesis and, therefore, may need further investigation, such as assessment of valve leaflet motion by transthoracic or transesophageal echocardiography or fluoroscopy. Valve regurgitation as evaluated by color Doppler flow mapping was mild in practically all CPs in the aortic position, and in the majority of CPs in the mitral position.

Aortic Valve↗