PubMed Health⌕ Search

Biomedical subjects

Neal F Viemeister

Publications and source records attributed to Neal F Viemeister.

9 recordsLinked to original sources

Discrimination of depth of sinusoidal amplitude modulation with and without roved carrier levels.

Thresholds for the discrimination of the depth of sinusoidal amplitude modulation with a broadband noise carrier were measured for three listeners in a two-alternative, forced-choice task for modulation frequencies of 8, 32, and 128 Hz. Thresholds were measured with the spectrum level of the carrier fixed at 20 dB across all trials and, separately, with the carrier spectrum level roved randomly over a 20-dB range (10-30 dB) in each interval. Mean thresholds were equal or slightly lower (but not significantly so) for the fixed conditions relative to the roved conditions, and the differences between thresholds were too small to be explained by assuming that listeners compared instantaneous intensity at corresponding phases of the modulation cycle (for example, in the troughs). Rather, it appears that listeners discriminated modulation depth by extracting an estimate of the modulation depth within each interval that was independent of the overall level. Consequently, models of envelope extraction must include normalization of the envelope fluctuations to the envelope dc.

Acoustic Stimulation↗

Discrimination of interaural phase differences in the envelopes of sinusoidally amplitude-modulated 4-kHz tones as a function of modulation depth.

Psychometric functions were measured for the discrimination of the interaural phase difference (IPD) of the envelope of a sinusoidally amplitude-modulated (SAM) 4-kHz pure tone for modulation frequencies of 128 and 300 Hz and modulation depths (m) of 0.2, 0.6, 0.9, and 1.0. Contrary to recent modeling assumptions, it was found that a constant change in normalized interaural envelope correlation, with or without additional model stages to simulate peripheral auditory processing, did not produce a constant level of performance. Rather, in some cases, performance could range from chance to near perfect across modulation depths for a given change in normalized interaural envelope correlation. This was also true for the maximum change in normalized interaural envelope correlation computed across the cross-correlation functions for the stimuli to be discriminated. The change in the interaural time difference (ITD) computed from the IPD accounted for discriminability across modulation depths better than the change in normalized interaural envelope correlation, although ITD could not account for all the data, particularly those for lower values of m.

Acoustic Stimulation↗

Monaural and interaural temporal modulation transfer functions measured with 5-kHz carriers.

Temporal modulation transfer functions (TMTFs) were measured for detection of monaural sinusoidal amplitude modulation and dynamically varying interaural level differences for a single set of listeners. For the interaural TMTFs, thresholds are the modulation depths at which listeners can just discriminate interaural envelope-phase differences of 0 and 180 degrees. A 5-kHz pure tone and narrowband noises, 30- and 300-Hz wide centered at 5 kHz, were used as carriers. In the interaural conditions, the noise carriers were either diotic or interaurally uncorrelated. The interaural TMTFs with tonal and diotic noise carriers exhibited a low-pass characteristic but the cutoff frequencies changed nonmonotonically with increasing bandwidth. The interaural TMTFs for the tonal carrier began rolling off approximately a half-octave lower than the tonal monaural TMTF (approximately 80 Hz vs approximately 120 Hz). Monaural TMTFs obtained with noise carriers showed effects attributable to masking of the signal modulation by intrinsic fluctuations of the carrier. In the interaural task with dichotic noise carriers, similar masking due to the interaural carrier fluctuations was observed. Although the mechanisms responsible for differences between the monaural and interaural TMTFs are unknown, the lower binaural TMTF cutoff frequency suggests that binaural processing exhibits greater temporal limitation than monaural processing.

Acoustic Stimulation↗

Forward masking of amplitude modulation: basic characteristics.

In this study we demonstrate an effect for amplitude modulation (AM) that is analogous to forward making of audio frequencies, i.e., the modulation threshold for detection of AM (signal) is raised by preceding AM (masker). In the study we focused on the basic characteristics of the forward-masking effect. Functions representing recovery from AM forward masking measured with a 150- ms 40- Hz masker AM and a 50- ms signal AM of the same rate imposed on the same broadband-noise carrier, showed an exponential decay of forward masking with increasing delay from masker offset. Thresholds remained elevated by more than 2 dB over an interval of at least 150 ms following the masker. Masked-threshold patterns, measured with a fixed signal rate (20, 40, and 80 Hz) and a variable masker rate, showed tuning of the AM forward-masking effect. The tuning was approximately constant across signal modulation rates used and consistent with the idea of modulation-rate selective channels. Combining two equally effective forward maskers of different frequencies did not lead to an increase in forward masking relative to that produced by either component alone. Overall, the results are consistent with modulation-rate selective neural channels that adapt and recover from the adaptation relatively quickly.

Acoustic Stimulation↗

Comparing monaural and interaural temporal windows: effects of a temporal fringe on sensitivity to intensity differences.

In an effort to provide a unifying framework for understanding monaural and binaural processing of intensity differences, an experiment was performed to assess whether temporal weighting functions estimated in two-interval monaural intensity-discrimination tasks could account for data in single-interval interaural intensity-discrimination tasks. In both tasks, stimuli consisted of a 50-ms burst of noise with a 5-ms probe segment at temporal positions ranging between the onset and offset of the overall stimulus. During the probe segment, one monaural interval or binaural channel of each trial contained an intensity increment and the other contained a decrement. Listeners were instructed to choose the interval/channel containing the increment. The pattern of monaural thresholds was roughly symmetrical (an inverted U) across temporal position of the probe but interaural thresholds were substantially higher for a brief time interval following stimulus onset. A two-sided exponential temporal window fit to the monaural data accounted for the interaural data well when combined with a post-onset-weighting function that described greatest weighting of binaural information at stimulus onset. A second experiment showed that the specific procedure used in measuring fringed interaural-intensity-difference-discrimination thresholds affects thresholds as a function of fringe duration and influences the form of the best-fitting post-onset-weighting function.

Acoustic Stimulation↗

Monaural and interaural intensity discrimination: level effects and the "binaural advantage".

This study examined whether the level effects seen in monaural intensity discrimination (Weber's law and the "near miss") in a two-interval task are also observed in discrimination of interaural intensity differences (IIDs) in a single-interval task. Both tasks were performed for various standard levels of 4-kHz pure tones and broadband noise. The Weber functions (10 log deltaI/I versus I in dB) in the monaural and binaural conditions were parallel. For noise, the Weber functions had slopes close to zero (Weber's law) while the Weber functions for the tones had a mean slope of -0.089 (near miss). The near miss for the monaural and binaural tasks with tones was eliminated when a high-pass masker was gated with the listening intervals. The near-miss was also observed for 250- and 1000-Hz tones in the binaural task despite overall decreased sensitivity to changes in IID at 1000 Hz. The binaural thresholds showed a small (about 2-dB) advantage over monaural thresholds only in the broadband noise conditions. More important, however, is the fact that the level effects seen monaurally are also seen binaurally. This suggests that the basic mechanisms responsible for Weber's law and the near miss are common to monaural and binaural processing.

Acoustic Stimulation↗

Intensity discrimination and increment detection in cochlear-implant users.

Intensity difference limens (DLs) were measured in users of the Nucleus 22 and Clarion v1.2 cochlear implants and in normal-hearing listeners to better understand mechanisms of intensity discrimination in electric and acoustic hearing and to evaluate the possible role of neural adaptation. Intensity DLs were measured for three modes of presentation: gated (intensity increments gated synchronously with the pedestal), fringe (intensity increments delayed 250 or 650 ms relative to the onset of the pedestal), and continuous (intensity increments occur in the presence of a pedestal that is played throughout the experimental run). Stimuli for cochlear-implant listeners were trains of biphasic pulses; stimuli for normal-hearing listeners were a 1-kHz tone and a wideband noise. Clarion cochlear-implant listeners showed level-dependent effects of presentation mode. At low pedestal levels, gated thresholds were generally similar to thresholds obtained in the fringe and continuous conditions. At higher pedestal levels, however, the fringe and continuous conditions produced smaller intensity DLs than the gated condition, similar to the gated-continuous difference in intensity DLs observed in acoustic hearing. Nucleus cochlear-implant listeners did not show consistent threshold differences for the gated and fringe conditions, and were not tested in the continuous condition. It is not clear why a difference between gated and fringe thresholds occurred for the Clarion but not the Nucleus subjects. Normal-hearing listeners showed improved thresholds for the continuous condition relative to the gated condition, but the effect was larger for the 1-kHz tonal carrier than for the noise carrier. Findings suggest that adaptation occurring central to the inner hair cell synapse mediates the gated-continuous difference observed in Clarion cochlear-implant listeners and may also contribute to the gated-continuous difference in acoustic hearing.

Acoustic Stimulation↗

Suprathreshold effects of adaptation produced by amplitude modulation.

This work extends the study of adaptation to amplitude modulation (AM) to the perception of highly detectable modulation. A fixed-level matching procedure was used to find perceptually equivalent modulation depths for 16-Hz modulation imposed on a 1-kHz standard and a 4-kHz comparison. The modulation depths in the two stimuli were compared before and after a 10-min exposure to a 1-kHz tone (adaptor) 100% modulated in amplitude at different rates. For modulation depths of 63% (20 log m = -4) and smaller, the perceived modulation depth was reduced after exposure to the adaptor that was modulated at the same rate as the standard. The size of this reduction expressed as a difference between the post- and pre-exposure AM depths was similar to the increase in AM-detection threshold observed after adaptation. Postexposure suprathreshold modulation depth was not appreciably reduced when the modulation depth of the standard was large (approached 100%). A much smaller or no reduction in the perceived modulation depth was also observed when the modulation rates of the adaptor and the standard tone were different. The tuning of the observed effect of the adaptor appears to be much sharper than the tuning shown by modulation-masking results.

Adaptation, Physiological↗