PubMed Health⌕ Search

Biomedical subjects

Neal K Bangerter

Publications and source records attributed to Neal K Bangerter.

3 recordsLinked to original sources

Dual-acquisition phase-sensitive fat-water separation using balanced steady-state free precession.

Balanced steady-state free precession (SSFP) sequences use fully re-focussed gradient waveforms to achieve a high signal and useful image contrast in short scan times. Despite these strengths, the clinical feasibility of balanced SSFP is still limited both by bright fat signal and by the signal voids that result from off-resonance effects such as field or susceptibility variations. A new method, dual-acquisition phase-sensitive SSFP, combines the signals from two standard balanced SSFP acquisitions to separate fat and water while simultaneously reducing the signal voids. The acquisitions are added in quadrature and then phase corrected using a simple algorithm before fat and water can be identified simply by the sign of the signal. This method is especially useful for applications at high field, where the RF power deposition, spatial resolution requirements and gradient strength limit the minimum repetition times. Finally, dual-acquisition phase-sensitive SSFP can be combined with other magnetization preparation schemes to produce specific image contrast in addition to separating fat and water signals.

Adipose Tissue↗

Fluid-attenuated inversion-recovery SSFP imaging.

PURPOSE: To describe and evaluate a fast, fluid-suppressed 2D multislice steady-state free precession (SSFP) neuroimaging sequence. MATERIALS AND METHODS: We developed a fast fluid-attenuated inversion-recovery SSFP sequence for use in neuroimaging. The inversion time (TI) was optimized to yield good cerebrospinal fluid (CSF) suppression while conserving white matter (WM)/lesion contrast across a broad range of flip angles. Multiple SSFP acquisitions were combined using the sum-of-squares (SOS) method to maximize SNR efficiency while minimizing SSFP banding artifacts. We compared our fluid-attenuated inversion-recovery (FLAIR) SSFP sequence with FLAIR fast spin-echo (FSE) in both normal subjects and a volunteer with multiple sclerosis. SNR measurements were performed to ascertain the SNR efficiency of each sequence. RESULTS: Our FLAIR SSFP sequence demonstrated excellent CSF suppression and good gray matter (GM)/WM contrast. Coverage of the entire brain (5-mm slices, 24-cm FOV, 256 x 192 matrix) was achieved with FLAIR SSFP in less than half the scan time of a corresponding FLAIR FSE sequence with similar SNR, yielding improvements of more than 50% in SNR efficiency. Axial scans of a volunteer with multiple sclerosis show clearly visible plaques and very good visualization of brain parenchyma. CONCLUSION: We have demonstrated the feasibility of a very fast fluid-suppressed neuroimaging technique using SSFP.

Algorithms↗

Analysis of multiple-acquisition SSFP.

Refocused steady-state free precession (SSFP) is limited by its high sensitivity to local field variation, particularly at high field strengths or the long repetition times (TRs) necessary for high resolution. Several methods have been proposed to reduce SSFP banding artifact by combining multiple phase-cycled SSFP acquisitions, each differing in how individual signal magnitudes and phases are combined. These include maximum-intensity SSFP (MI-SSFP) and complex-sum SSFP (CS-SSFP). The reduction in SSFP banding is accompanied by a loss in signal-to-noise ratio (SNR) efficiency. In this work a general framework for analyzing banding artifact reduction, contrast, and SNR of any multiple-acquisition SSFP combination method is presented. A new sum-of-squares method is proposed, and a comparison is performed between each of the combination schemes. The sum-of-squares SSFP technique (SOS-SSFP) delivers both robust banding artifact reduction and higher SNR efficiency than other multiple-acquisition techniques, while preserving SSFP contrast.

Artifacts↗