PubMed Health⌕ Search

Biomedical subjects

Neelam Tyagi

Publications and source records attributed to Neelam Tyagi.

4 recordsLinked to original sources

A proposed alternative to phase-space recycling using the adaptive kernel density estimator method.

We have implemented a nonparametric density estimation technique, the adaptive kernel density estimator (AKDE), to generate additional phase space (PS) variables in the vicinity of simulated PS points in Monte Carlo linear accelerator simulation. The method involves the placement of kernels at simulated PS points that have a "window width" that depends on the density of simulated PS points. This method has been tested on known one-dimensional (1-D) and two-dimensional (2-D) probability density functions (PDFs) and has been used to sample (photons only) from PS files generated from accelerator simulations. The original simulated PS vector (x, y, u, v, E) was reduced to a rotationally invariant PS vector (r, theta, alpha, E) that takes advantage of the azimuthal symmetry (phi) above the collimating jaws. The new PS vector (r', theta', alpha', E') is sampled in the vicinity of the sampled PS vector (r, theta, alpha, E). The first step in assessing the accuracy of the method was a correlation analysis among the AKDE generated PS variables compared with correlations among the original PS variables. "In-air" particle fluence distributions between AKDE samples and the original PS distribution showed agreement within 2% (-8.8% to 6.8%) across the entire phase space plane. Central axis energy distributions and angular distributions agreed on average to within 1.5% (range = -1.5% to 6.6%) and 0.1% (range = 0 to 3.0%), respectively. Dose profiles were calculated for field sizes 3 x 3 cm2, 10 x 10 cm2, and 30 x 30 cm2 for AKDE and compared against calculations performed with PS recycling. AKDE calculated depth doses and profiles were within 2% and 2%/1 mm, respectively, of those computed using PS recycling.

Algorithms↗

Implementation of the DPM Monte Carlo code on a parallel architecture for treatment planning applications.

We have parallelized the Dose Planning Method (DPM), a Monte Carlo code optimized for radiotherapy class problems, on distributed-memory processor architectures using the Message Passing Interface (MPI). Parallelization has been investigated on a variety of parallel computing architectures at the University of Michigan-Center for Advanced Computing, with respect to efficiency and speedup as a function of the number of processors. We have integrated the parallel pseudo random number generator from the Scalable Parallel Pseudo-Random Number Generator (SPRNG) library to run with the parallel DPM. The Intel cluster consisting of 800 MHz Intel Pentium III processor shows an almost linear speedup up to 32 processors for simulating 1 x 10(8) or more particles. The speedup results are nearly linear on an Athlon cluster (up to 24 processors based on availability) which consists of 1.8 GHz+ Advanced Micro Devices (AMD) Athlon processors on increasing the problem size up to 8 x 10(8) histories. For a smaller number of histories (1 x 10(8)) the reduction of efficiency with the Athlon cluster (down to 83.9% with 24 processors) occurs because the processing time required to simulate 1 x 10(8) histories is less than the time associated with interprocessor communication. A similar trend was seen with the Opteron Cluster (consisting of 1400 MHz, 64-bit AMD Opteron processors) on increasing the problem size. Because of the 64-bit architecture Opteron processors are capable of storing and processing instructions at a faster rate and hence are faster as compared to the 32-bit Athlon processors. We have validated our implementation with an in-phantom dose calculation study using a parallel pencil monoenergetic electron beam of 20 MeV energy. The phantom consists of layers of water, lung, bone, aluminum, and titanium. The agreement in the central axis depth dose curves and profiles at different depths shows that the serial and parallel codes are equivalent in accuracy.

Algorithms↗

Photon beam relative dose validation of the DPM Monte Carlo code in lung-equivalent media.

Validation experiments have been conducted using 6 and 15 MV photons in inhomogeneous (water/lung/water) media to benchmark the accuracy of the DPM Monte Carlo code for photon beam dose calculations. Small field sizes (down to 2 x 2 cm2) and low-density media were chosen for this investigation because the intent was to test the DPM code under conditions where lateral electronic disequilibrium effects are emphasized. The treatment head components of a Varian 21EX linear accelerator, including the jaws (defining field sizes of 2 x 2, 3 x 3 and 10 x 10 cm2), were simulated using the BEAMnrc code. The phase space files were integrated within the DPM code system, and central axis depth dose and profile calculations were compared against diode measurements in a homogeneous water phantom in order to validate the phase space. Results of the homogeneous phantom study indicated that the relative differences between DPM calculations and measurements were within +/- 1% (based on the rms deviation) for the depth dose curves; relative profile dose differences were on average within +/- 1%/1 mm. Depth dose and profile measurements were carried out using an ion-chamber and film, within an inhomogeneous phantom consisting of a 6 cm slab of lung-equivalent material embedded within solid water. For the inhomogeneous phantom experiment, DPM depth dose calculations were within +/- 1% (based on the rms deviation) of measurements; relative profile differences at depths within and beyond the lung were, on average, within +/- 2% in the inner and outer beam regions, and within 1-2 mm distance-to-agreement within the penumbral region. Relative point differences on the order of 2-3% were within the estimated experimental uncertainties. This work demonstrates that the DPM Monte Carlo code is capable of accurate photon beam dose calculations in situations where lateral electron disequilibrium effects are pronounced.

Algorithms↗

A fluence convolution method to account for respiratory motion in three-dimensional dose calculations of the liver: a Monte Carlo study.

We describe the implementation of a fluence convolution method to account for the influence of superior-inferior (SI) respiratory induced motion on a Monte Carlo-based dose calculation of a tumor located in the liver. This method involves convolving the static fluence map with a function describing the SI motion of the liver-the motion function has been previously derived from measurements of diaphragm movement observed under fluoroscopy. Significant differences are noted between fluence-convolved and static dose distributions in an example clinical treatment plan; hot and cold spots (on the order of 25%) are observed in the fluence-convolved plan at the superior and inferior borders of the liver, respectively. This study illustrates that the fluence convolution method can be incorporated into Monte Carlo dose calculation algorithms to account for some of the effects of patient breathing during radiotherapy treatment planning, thus leading to more accurate dose calculations.

Algorithms↗