Phasic diastolic coronary narrowings.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to Neeraj Jolly.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Three-dimensional (3D) echocardiography (3DE) provides unique orientations of the mitral valve (MV) not obtainable by routine 2-dimensional echocardiography. However, this modality has not been adopted in routine clinical practice because of its cumbersome and time-consuming process. The recent introduction of a full matrix-array transducer has enabled online real-time 3DE (RT3DE) and rendering. This study was designed to: (1) determine the clinical use of RT3DE in patients with MV pathology and in a control group selected for their good acoustic windows (protocol I); and (2) to investigate the feasibility of imaging the MV apparatus in a large group of consecutively imaged patients to determine the acoustic window or perspective from which the MV leaflets, commissures, and orifice are best visualized (protocol II). In protocol I, 65 patients were selected based on MV pathology and good 2-dimensional echocardiography image quality. Protocol II included 150 patients who were consecutively imaged using RT3DE. Images were viewed online (protocol I) and offline on a digital review station (protocol II). RT3DE visualization of the MV apparatus was graded based on the percentage of leaflet dropout and definition. In protocol I, 78% of patients had adequate 3D MV reconstructions with complete visualization of the anterior mitral leaflet (AML) in 84% versus the posterior mitral leaflet (PML) in 77%. The mitral leaflets, commissures, and MV orifice were well seen in 98%; however, the submitral apparatus was only observed in 76% of the patients. RT3DE: (1) correctly identified the prolapsed/flailed scallop in 6 of 8 patients; (2) obtained en face orientation of the MV orifice in 9 of 11 patients with mitral stenosis, allowing accurate measurements of the orifice area and evaluation of the immediate effects of balloon mitral valvuloplasty; and (3) allowed postoperative evaluation of MV repair and the integrity of the struts of a bioprosthetic leaflet. In protocol II, 70% of patients had adequate RT3DE with complete visualization of the AML noted in 55% versus 51% for PML. The mitral leaflets, commissures, and MV orifice were observed in 69%. Irrespective of acquisition window, the AML was best seen from a ventricular perspective. In contrast, the PML was optimally examined from a parasternal window. Both the medial and lateral commissures were equally assessed from either imaging window. In conclusion, RT3DE of the MV is feasible in a large majority of patients. Using different MV acquisitions RT3DE provides important clinical information such as: (1) identification of a prolapsed/flail scallop; (2) measurement of stenotic valve areas; (3) evaluation of MV leaflet integrity postrepair; and (4) identification of a MV perforation. In general the AML is better visualized than the PML. The parasternal window is the optimal approach to visualize both AML and PMLs.
The current treatment of massive pulmonary embolism (PE) has been either thrombolysis or surgical embolectomy. Percutaneous rheolytic thrombectomy, however, has emerged as an alternative treatment in patients with contraindications to thrombolysis. This case illustrates the usefulness of the AngioJet(R) thrombectomy catheter in patients with contraindications to thrombolytics. Three-dimensional computed tomography imaging demonstrated the effectiveness of treatment in this patient with massive PE.
Myocardial bridges, with resultant systolic compression of the coronary artery, are common inborn anomalies that generally have a benign course. Diastolic compression of the coronary artery, however, is a rare finding that is believed to be an acquired lesion. It can be hypothesized that during diastole, when left ventricular filling occurs, the coronary artery is compressed against epicardial scar tissue or a noncompliant pericardium. This can then lead to diminished intracoronary blood flow. We present a case of functionally significant diastolic coronary artery compression in a cardiac transplant recipient who was successfully treated with intracoronary stent placement.
Explore the source record for details and available documents.
Sinus of Valsalva aneurysms are rare congenital anomalies. When they rupture, they can lead to the development of biventricular failure as a result of systemic-pulmonary shunting. Surgical repair has been the traditional treatment for these aneurysms. We present a case of a 54 year old man in whom a ruptured sinus of Valsalva aneurysm was successfully closed using a catheter-based approach with the Amplatzer Duct Occluder.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Percutaneous suture closure for femoral artery hemostasis has gained broad use over the last few years since its introduction. The appeal of suture closure is the immediate and definitive hemostasis that it achieves, even in anticoagulated patients. Described is the use of the Perclose Techstar XL 6Fr suture closure device for the management of brachial artery puncture after diagnostic and therapeutic catheterization. A 6Fr Perclose Techstar device was used for hemostasis during ten procedures in eight patients. In addition, 6Fr and 7Fr sheaths were used. Hemostasis was achieved in all but one patient, in whom hemostasis was not achieved and surgical repair was necessary. The Perclose Techstar device is useful for selected patients for achieving brachial arterial puncture site hemostasis. The large excursion of the foot of the new closer device may not be as applicable in arteries as small as the brachial artery. Patients who are obese may be best suited for this approach.