PubMed Health⌕ Search

Biomedical subjects

Neil A Thacker

Publications and source records attributed to Neil A Thacker.

5 recordsLinked to original sources

Robust quantification of short echo time 1H magnetic resonance spectra using the Padé approximant.

Accurate quantification of in vivo short echo time spectra is hampered by the presence of overlapping peaks and a significant baseline. In this work the Padé approximant in conjunction with Monte Carlo simulation is used to extract peak areas from short echo time 1H spectra. We exploit the fact that the Padé approximant is known to model broad non-Lorentzian signals as arbitrary sums of Lorentzian components to separate baseline components from sharper metabolite signals by combining the Padé approximant with Monte Carlo simulation. The simulation results demonstrate that the Padé approximant-Monte Carlo hybrid analysis is able to separate the metabolite signals from the baseline, while a least squares fitting of a time domain model may result in significant bias of the peak area estimations. For the in vivo data the estimates of the peak areas using the Padé approximant and AMARES compare well, with the exception of the NAA peak at 2.02 ppm. We suggest that the discrepancy may be due to the baseline contamination as supported by the simulation results; however, without an in vivo gold standard this remains difficult to demonstrate.

Adult↗

Effects of intramolecular dipolar coupling on the isotropic-nematic phase transition of a hard spherocylinder fluid.

The thermodynamics of a simple model, containing the minimum set of features required to provide liquid crystal-like phase behavior and the dipolar coupling observable in the NMR spectrum of orientationally ordered fluids, are presented within the framework of Onsager theory. The model comprises a fluid of hard spherocylinders with a pair of embedded freely rotating magnetic dipoles. The behavior of the isotropic-nematic phase transition is explored as a function magnetic field strength and of the relative orientation between the nematic director and the external magnetic field. When the field and director are aligned the phase diagram is similar to those predicted for a hard rod fluid in flow fields, electric fields, and magnetic fields, with the field promoting orientational order in the fluid and the isotropic-nematic phase transition being replaced by a paranematic-nematic phase transition. In contrast, when the field and director are perpendicular, the field destabilizes the nematic phase and the phase transition is shifted to higher densities. The variation of the mean magnetic moment and the dipolar coupling are examined as a function of the orientational structure of the fluid. The model is used to support the hypothesis that dipolar couplings observed in the spectra of human leg muscle originate from nematic-like liquid crystal phases in relatively small metabolite molecules. The fitted theoretical predictions of the dependence of the dipolar coupling on the orientation of the field with respect to the nematic director are shown to provide a good description of the experimental data.

Journal Article↗

Robust tissue boundary detection for cerebral cortical thickness estimation.

This paper presents an algorithm for determining regional cerebral grey matter cortical thickness from magnetic resonance scans. In particular, the modification of a gradient-based edge detector into an iso-grey-level boundary detector for reliably determining the low-contrast grey-white matter interface is described and discussed. The reproducibility of the algorithm over 31 gyral regions is assessed using repeat scans of four subjects, and a technique for correcting the misplacement of the grey-white matter boundary is shown to significantly reduce the systematic error on the reproducibility.

Adult↗

Dementing disorders: volumetric measurement of cerebrospinal fluid to distinguish normal from pathologic findings -- feasibility study.

The authors describe a magnetic resonance (MR) imaging technique to quantify the severity and distribution of cerebral atrophy by using automated volumetric analysis of the distribution of cerebrospinal fluid. The MR imaging technique demonstrated high diagnostic sensitivity and specificity in a group of healthy subjects and patients with dementing diseases. The authors conclude that this approach provides valuable clinical information that is complementary to information acquired with standard diagnostic practices.

Age Factors↗

Using Bayesian tissue classification to improve the accuracy of vestibular schwannoma volume and growth measurement.

BACKGROUND AND PURPOSE: True 3D measurements of tumor volume are time-consuming and subject to errors that are particularly pronounced in cases of small tumors. These problems complicate the routine clinical assessment of tumor growth rates. We examined the accuracy of currently available methods of size and growth measurement of vestibular schwannomas compared with that of a novel fast partial volume tissue classification algorithm. METHODS: Sixty-three patients with unilateral sporadic vestibular schwannomas underwent imaging. Thirty-eight of these patients underwent imaging two or more times at approximately 12-month intervals. Contrast-enhanced 3D T1-weighted images were used for all measurements. An experienced radiologist performed standard size estimations, including maximal diameter, elliptical area, perimeter, manually segmented area, intensity thresholded seeding volume, and manually segmented volume. A method for calculating volume was also used, incorporating Bayesian probability statistics to estimate partial volume effects. Manually segmented volume was obtained as a baseline standard measure. A computer-generated phantom exhibiting the intensity and partial volume characteristics of brain tissue, CSF, and intracanalicular vestibular schwannoma tissue was used to measure absolute accuracy of the standard technique and Bayesian partial volume segmentation. RESULTS: The Bayesian partial volume segmentation method showed the highest correlation (R(2) = 0.994) with the standard method, whereas the commonly used method of maximal diameter measurement showed poor correlation (R(2) = 0.732). Accuracy of Bayesian segmentation was shown to be more than twice that of manual segmentation, with an absolute accuracy of 5% (cf, 13%) and a remeasurement accuracy of 70 mm(3) (cf, 150 mm(3)). For the 38 patients who underwent imaging twice, definite tumor growth was shown for 12, potential growth for seven, no growth for 17, and definite shrinkage for two. CONCLUSION: Commonly used methods such as maximal diameter measurements do not provide adequate statistical accuracy with which to monitor tumor growth in patients with small vestibular schwannomas. Bayesian partial volume segmentation provides a more accurate and rapid method of volume and growth estimation. These differences in measurement accuracy translated into a significant improvement in clinical assessment, allowing identification of tumor growth in 10 of 12 cases that appeared to be static in size when manual segmentation techniques are used. The technique is quick to perform and suitable for use in routine clinical practice.

Adult↗