PubMed Health⌕ Search

Biomedical subjects

Niall Patton

Publications and source records attributed to Niall Patton.

At least 19 recordsLinked to original sources

OSCA: a comprehensive open-access system of analysis of posterior capsular opacification.

BACKGROUND: This paper presents and tests a comprehensive computerised system of analysis of digital images of posterior capsule opacification (PCO). It updates and expands significantly on a previous presentation to include facilities for selecting user defined central areas and for registering and subsequent merging of images for artefact removal. Also, the program is compiled and thus eliminates the need for specialised additional software. The system is referred to in this paper as the open-access systematic capsule assessment (OSCA). The system is designed to be evidence based, objective and openly available, improving on current systems of analysis. METHODS: Principal features of the OSCA system of analysis are discussed. Flash artefacts are automatically located in two PCO images and the images merged to produce a composite free from these artefacts. For this to be possible the second image has to be manipulated with a registration technique to bring it into alignment with the first. Further image processing and analysis steps use a location-sensitive entropy based texture analysis of PCO. Validity of measuring PCO progression of the whole new system is assessed along with visual significance of scores. Reliability of the system is assessed. RESULTS: Analysis of PCO by the system shows ability to detect early progression of PCO, as well as detection of more visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is demonstrated. CONCLUSION: This system of PCO analysis is evidence-based, objective and clinically useful. It incorporates flash detection and removal as well as location sensitive texture analysis. It provides features and benefits not previously available to most researchers or clinicians. Substantial evidence is provided for this system's validity and reliability.

Cataract↗

Asymmetry of retinal arteriolar branch widths at junctions affects ability of formulae to predict trunk arteriolar widths.

PURPOSE: To describe a revised formula for the estimation of retinal trunk arteriole widths from their respective arteriolar branch widths that improves the summarizing of retinal arteriolar diameters. METHODS: A group of young, healthy individuals underwent retinal photography and arteriolar and venular branching points were identified. Vessel widths of the vessel trunks and their branches were determined. The relationship between the branching coefficient (BC; quotient of the area of the branch and trunk vessels) and the asymmetry index (AI) of the vessel branches was explored. The result was used to formulate a new BC. To test the new BC, a second group of young, healthy individuals also underwent retinal photography. Arteriolar branching points were identified, and the trunk and branch arteriolar widths were recorded. This "revised" BC was compared against the gold standard of the BC as a constant value (1.28), as well as a theoretical formula for the BC that includes the angle between the two vessel branches. RESULTS: The BC of arterioles (but not venules) related to the AI (R = 0.275, P = 0.0001; BC arterioles = 0.78 +/- 0.63 . AI). In the second group, the mean arteriolar trunk diameter was 15.56 pixels. The linear regression model for the arteriolar BC was superior to the BC constant of 1.28 (mean difference between estimated and calculated trunk vessel width was 2.16 vs. 2.23 pixels, respectively). The model based on the angle between the branch arterioles was the least accurate (3.43 pixels). CONCLUSIONS: A revised formula has been devised for the arteriolar BC using a linear regression model that incorporates its relationship to the AI. Further studies using this refined formula to calculate the BC are needed to determine whether it improves the ability to detect smaller associations between the retinal vascular network and cardiovascular disease.

Adult↗

Retinal image analysis: concepts, applications and potential.

As digital imaging and computing power increasingly develop, so too does the potential to use these technologies in ophthalmology. Image processing, analysis and computer vision techniques are increasing in prominence in all fields of medical science, and are especially pertinent to modern ophthalmology, as it is heavily dependent on visually oriented signs. The retinal microvasculature is unique in that it is the only part of the human circulation that can be directly visualised non-invasively in vivo, readily photographed and subject to digital image analysis. Exciting developments in image processing relevant to ophthalmology over the past 15 years includes the progress being made towards developing automated diagnostic systems for conditions, such as diabetic retinopathy, age-related macular degeneration and retinopathy of prematurity. These diagnostic systems offer the potential to be used in large-scale screening programs, with the potential for significant resource savings, as well as being free from observer bias and fatigue. In addition, quantitative measurements of retinal vascular topography using digital image analysis from retinal photography have been used as research tools to better understand the relationship between the retinal microvasculature and cardiovascular disease. Furthermore, advances in electronic media transmission increase the relevance of using image processing in 'teleophthalmology' as an aid in clinical decision-making, with particular relevance to large rural-based communities. In this review, we outline the principles upon which retinal digital image analysis is based. We discuss current techniques used to automatically detect landmark features of the fundus, such as the optic disc, fovea and blood vessels. We review the use of image analysis in the automated diagnosis of pathology (with particular reference to diabetic retinopathy). We also review its role in defining and performing quantitative measurements of vascular topography, how these entities are based on 'optimisation' principles and how they have helped to describe the relationship between systemic cardiovascular disease and retinal vascular changes. We also review the potential future use of fundal image analysis in telemedicine.

Animals↗

Effect of axial length on retinal vascular network geometry.

PURPOSE: To explore the association between axial length and retinal vascular network geometry (arteriovenous diameter ratio [AVR], arteriolar branching angles, and junctional exponents). DESIGN: Prospective, cross-sectional study. METHODS: Patients were recruited from a pseudophakic population that had preexisting axial length measurements. Mean arterial blood pressure and previous medical history were recorded. Fundal photographs were taken. Digital image analysis was used to determine the AVR, mean arteriolar bifurcation angle, and junctional exponent for each subject. RESULTS: In total, 52 subjects were analyzed. Axial length had no association with AVR (R = -0.01, P = .941), mean angles at arteriolar bifurcations (R = -.134, P = .342), or junctional exponents (R = .003, P = .982). However, increased axial length was associated with a trend for lower measured retinal venular and arteriolar diameters (R = -.28, P = .04 and R = -.23, P = .10, respectively). Junctional exponents correlated with both the AVR (R = .32, P = .019) and vascular bifurcation angles (omega) (R = .317, P = .022). CONCLUSIONS: Increased axial length is associated with narrowing of both arteriolar and venular diameters, but not on the AVR, or vessel junctions. Future studies exploring the influence of systemic disease on retinal vascular topography do not need to consider axial length as a potential confounding variable when utilizing measures such as AVR or vessel junctions. Vascular arteriolar junctional exponents may serve as a good measure of overall altered retinal vascular geometry in cardiovascular disease.

Adult↗

A freely accessible, evidence based, objective system of analysis of posterior capsular opacification; evidence for its validity and reliability.

BACKGROUND: The aim of this study was to develop a system of computerised analysis of digital images of posterior capsule opacification (PCO) that is evidence based, objective and freely available. The paper will present evidence for the reliability and validity of the developed system. METHODS: The system of PCO analysis was developed considering current published evidence on visual significance of PCO and additional investigative analysis of PCO images. Details of the image processing and analysis steps are discussed and a final system that measures an entropy score weighted toward proximity to central areas is described. In order to assess validity, the systems ability to measure PCO progression is assessed along with the visual significance of its final computerised scores. Reliability of the system is also assessed. RESULTS: The final system runs successfully and is simple to use. Analyses of PCO by the system show an ability to detect early progression of PCO as well as detection of visually significant PCO. Images with no clinical PCO produce very low scores in the analysis. Reliability of the system of analysis is shown to be satisfactory. CONCLUSION: This paper presents a system of PCO analysis that is evidence based, objective and clinically useful. Substantial evidence is provided for its validity and reliability.

Access to Information↗

Measurement validity in ophthalmology.

Measurements in ophthalmic research may be of parameters such as visual functions, quality of life or physical measures and can involve different types of instruments such as questionnaires and mechanical, chemical or electronic devices. Whatever the mode of measurement, however, all these devices require sufficient evidence for validity before inferences can be made on the basis of their findings. This article explores the nature and often overlooked importance of validity and explains some of the terminology involved. It discusses the main forms that ophthalmologists should be aware of before they can assess whether the instruments, old and new, are providing results upon which inferences can be made with any level of confidence. The literature search involved use of Medline, PubMed and Ovid as well as referenced papers in journals and books. Searches were comprehensive and international. Foreign texts were translated.

Data Collection↗

Retinal vascular image analysis as a potential screening tool for cerebrovascular disease: a rationale based on homology between cerebral and retinal microvasculatures.

The retinal and cerebral microvasculatures share many morphological and physiological properties. Assessment of the cerebral microvasculature requires highly specialized and expensive techniques. The potential for using non-invasive clinical assessment of the retinal microvasculature as a marker of the state of the cerebrovasculature offers clear advantages, owing to the ease with which the retinal vasculature can be directly visualized in vivo and photographed due to its essential two-dimensional nature. The use of retinal digital image analysis is becoming increasingly common, and offers new techniques to analyse different aspects of retinal vascular topography, including retinal vascular widths, geometrical attributes at vessel bifurcations and vessel tracking. Being predominantly automated and objective, these techniques offer an exciting opportunity to study the potential to identify retinal microvascular abnormalities as markers of cerebrovascular pathology. In this review, we describe the anatomical and physiological homology between the retinal and cerebral microvasculatures. We review the evidence that retinal microvascular changes occur in cerebrovascular disease and review current retinal image analysis tools that may allow us to use different aspects of the retinal microvasculature as potential markers for the state of the cerebral microvasculature.

Aging↗

Sub-Tenon's anesthetic administration for cataract surgery: how much stays in?

UNLABELLED: We performed a prospective, randomized trial assessing the "remaining" volume of anesthetic solution that stays within the sub-Tenon's space after administration of 2 different volumes: 3 mL and 5 mL. The remaining volume correlated with motor block (r = 0.72; P < 0.001). The volume lost through the incision as a percentage of total volume injected was similar in both groups, suggesting sub-Tenon's space is not limited to a finite injected volume less than 5 mL and may be capable of receiving larger volumes of anesthetic to improve motor block. IMPLICATIONS: The volume of anesthetic solution remaining within sub-Tenon's space correlates with motor block. The amount of volume lost as a percentage of total administered is independent of the volume injected, suggesting sub-Tenon's space is not limited to a finite injected volume less than 5 mL and may be capable of receiving larger volumes of anesthetic to improve motor block.

Aged↗

Methods of assessment of patients for Nd:YAG laser capsulotomy that correlate with final visual improvement.

BACKGROUND: This paper attempts to clarify the usefulness of various simple pre-operative measures in estimating the potential for a visually successful capsulotomy. METHODS: 24 patients attending for capsulotomy had pre-operative measures of glare with BAT tester, visibility of posterior pole and grading of posterior capsular pearls and fibrosis seen at slit lamp. Visual function was measured before and after standardised capsulotomy. Correlations of the various preoperative measures with eventual visual function improvements were calculated. RESULTS: Pearls at slit lamp and poor posterior pole visualisation were all correlated with improvements in visual acuity and contrast sensitivity after capsulotomy. Amount of fibrosis visible at slit lamp and glare assessment were not correlated with vision improvements after laser. CONCLUSION: Of the various measures that are taken prior to Nd : YAG capsulotomy, some correlate with eventual visual improvement but for others no clinical utility was found. Practitioners should note these findings as they are especially of use in more questionable or high-risk cases to help determine whether referral for PCO treatment by Nd: YAG capsulotomy is likely to benefit the patient.

Aged↗

Does a small central Nd:YAG posterior capsulotomy improve peripheral fundal visualisation for the vitreoretinal surgeon?

BACKGROUND: To evaluate the effect of Nd:YAG capsulotomy for posterior capsular opacification (PCO) on visualisation of the peripheral fundus with scleral indentation. METHODS: Patients undergoing Nd:YAG capsulotomy for PCO were examined pre- and four weeks post- Nd:YAG capsulotomy. In order to give a quantitative measure of visualisation of the peripheral retina, a novel scalar measurement was developed. Changes in the degree of visualisation following Nd:YAG capsulotomy were calculated. RESULTS: There was a significant improvement in fundal visualisation of the retinal periphery with scleral indentation following Nd:YAG capsulotomy (p = 0.001). CONCLUSION: Peripheral fundal visualisation with scleral indentation improves following a small central Nd:YAG capsulotomy. This finding is important in relation to the detection of peripheral pseudophakic retinal breaks, particularly in those patients deemed at high risk following Nd:YAG capsulotomy.

Aged↗

Pupillary anomaly masquerading as a glaucomatous visual field defect: a case report.

BACKGROUND: Patients are often referred to ophthalmologists with focal visual field defects on routine testing, possibly related to a potential diagnosis of glaucoma. However, examination of the individual patient's ocular characteristics as well as facial characteristics may often reveal a cause of the visual field defect. CASE PRESENTATION: We describe a patient who was found to have a superior visual field defect on routine testing by the optician. Repeat perimetry with pharmacological dilatation of the pupil revealed that the cause of the field defect was related to an eccentric inferiorly displaced pupil, secondary to trauma some years previously. DISCUSSION: Individual patient characteristics, including both ocular, as well as facial, need to be considered, when interpreting any visual field defect.

Aged↗

Effect of the Honan intraocular pressure reducer in sub-Tenon's anesthesia.

PURPOSE: To ascertain whether the Honan intraocular pressure reducer (HIPR) has an effect on the preoperative intraocular pressure (IOP), surgeon's assessment of anesthesia, and patients' analgesic experience when sub-Tenon's anesthesia is used for routine cataract surgery. SETTING: Princess Alexandra Eye Pavilion, Edinburgh, Scotland. METHOD: Forty-five eyes of 45 patients having routine phacoemulsification cataract surgery were randomized to receive 10 minutes of ocular compression using the HIPR or no compression after administration of sub-Tenon's anesthesia. The IOP was measured immediately before and immediately and 10 minutes after sub-Tenon's anesthesia administration using a standard technique. One surgeon who was masked to the randomization process performed all injections and completed a questionnaire on aspects of the anesthetic block. Patients scored their level of analgesia during surgery. RESULTS: The mean rise in IOP immediately after administration of sub-Tenon's anesthesia was 1.39 mm Hg +/- 3.91 (SD) (95% confidence interval +0.22 to 2.57; P =.021). In the 22 patients who received compression, there was a mean IOP reduction of 4.20 +/- 2.74 mm Hg at 10 minutes. The mean difference between the compression and no-compression groups at 10 minutes was 4.99 mm Hg (P<.0001). There was no difference in the surgeon's scores for any aspect of the sub-Tenon's anesthesia (P>.05). All patients reported good levels of analgesia. CONCLUSIONS: There was a significant reduction in IOP after compression using the HIPR. However, the rise in IOP after administration of sub-Tenon's anesthesia was small and the use of the HIPR did not make a significant difference in the effectiveness of the anesthesia to the surgeon or patients.

Aged↗