Monitoring glaucomatous visual field progression: the effect of a novel spatial filter.

PURPOSE: To assess the impact of a novel visual field spatial filtering technique on the detection of glaucomatous progression. METHODS: One hundred ninety-eight ocular hypertensive (OHT) and 21 control subjects were examined prospectively (1994-2001) with regular full-threshold Humphrey visual field (VF) testing. VF progression was assessed by point-wise linear regression (PLR) of sensitivity/time in Progressor for Windows software modified to include a novel spatial filter. Standard progression criteria (slope > -1 dB/year, P < 0.01) were applied to both "raw" (unfiltered) and "filtered" VF series. Three-omitting confirmatory VF criteria were also applied to unfiltered VF series. Specificity was estimated as the proportion of progressing control subjects and as the proportion of significantly improving subjects (both OHT and control) at the end of the study period. RESULTS: Applying standard PLR, specificity was estimated at 91.8% to 97.5% using unfiltered standard PLR, compared with 93.5% to 98.4% using filtered standard PLR and 95.4% to 99.3% using unfiltered three-omitting PLR. The rate of identified VF progression in the OHT cohort was 32.3% with unfiltered standard PLR, 28.7% with filtered standard PLR, and 18.6% with unfiltered three-omitting PLR. There was no significant difference in time to detected progression between filtered and unfiltered standard PLR. CONCLUSIONS: The use of confirmatory tests resulted in improved specificity using unfiltered data; however, application of the spatial filter resulted in similar specificity but with a higher rate of detected progression. This filter may therefore be useful in the monitoring of glaucomatous progression as it may reduce the dependence on confirmatory testing, although it has yet to be applied to longitudinal SITA data.

Adult↗

Optic disc and visual field progression in ocular hypertensive subjects: detection rates, specificity, and agreement.

PURPOSE: To examine the detection rates, specificity, and agreement between visual field (VF) progression and Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, GmbH, Heidelberg, Germany) rim area (RA) progression in subjects with ocular hypertension (OHT). METHODS: One hundred ninety-eight OHT and 21 control subjects were examined prospectively (1994-2001) with regular Humphrey VF (Carl Zeiss Meditec, Inc., Dublin, CA) and HRT testing. Point-wise linear regression (PLR) of sensitivity/time was used to assess VF progression, using standard and three-omitting (less stringent and stringent) criteria. The change in HRT-detected progression was assessed by linear regression of sectoral RA/time, defined as slope>1%/year, with significance level tailored according to series variability. Less stringent and stringent criteria were tested. Specificity was estimated by the proportions of control subjects with disease progression and significantly improving subjects (all). Agreement between disc and field progression in the subjects with OHT was assessed with specificities matched for both VF and HRT. RESULTS: Specificity for VF PLR was estimated to be 85.7% to 95.4% when standard criteria were used, and for RA/time to be 88.1% to 90.5% with the less-stringent criteria. In this comparison, 21.2% progressed by RA alone and 20.2% by VF alone, and 12.1% progressed by both RA and VF. Specificity was estimated to be 95.2% to 98.2% for both VF PLR and RA/time, using the three-omitting criteria and the stringent RA/time criteria, respectively. In this comparison, 8.6% progressed by RA alone, 15.1% by VF alone, and 3.5% by both RA and VF. CONCLUSIONS: A relatively high frequency of detected disease progression was observed with either method, with progression by VF occurring at least as frequently as progression by RA. Poor agreement between RA and VF progression was observed regardless of the specificity of the progression criteria. The results indicate that, in patients with ocular hypertension, monitoring of both VF and optic disc is necessary, as agreement between optic disc and VF progression is the exception rather than the rule.

Adult↗

Structure and function in glaucoma: The relationship between a functional visual field map and an anatomic retinal map.

PURPOSE: To examine the relationship between an anatomic map relating the retinal nerve fiber layer (RNFL) distribution to the optic nerve head and a functional map derived from the interpoint correlation of raw sensitivities in visual field (VF) testing. METHODS: Previously, interpoint correlations were generated for all possible pairs of VF test points in a dataset of 98,821 Humphrey VF test results taken from the Moorfields Eye Hospital archive. The relationship between these correlations and the physical distance between the VF test point pairs was evaluated by Pearson's correlation coefficient and multiple regression analysis. The distance between the pairs of VF test points was calculated in two ways. First, the anatomic map was used to estimate the angular distance at the optic nerve head (ONH), between the RNFL bundles corresponding to the VF test points in each pair (ONHd). Second, the retinal distance between pairs of test points was calculated from the Humphrey VF template (RETd). A best-fit model for predicting functional correlation (FC) from ONHd and RETd was constructed and used to formulate a filter incorporating the anatomic-functional correlation data. RESULTS: All scatterplots showed a negative association between interpoint retinal sensitivity correlation values and distance between points: ONHd (R2 = 0.60) and RETd (R2 = 0.33). The raw sensitivity correlation values could be predicted from a multiple regression model using ONHd, RETd, and a combined interaction of ONHd and RETd (R2 = 0.75, P < 0.00001). The construction of a new filter was based on the equation FC = 0.9325 - (0.0029 . ONHd) - (0.0077 . RETd) + (0.0001 . ONHd . RETd). CONCLUSIONS: A good level of association was observed between the strength of correlation between points in the VF and the relative location of those test points in the peripheral retina and in corresponding RNFL bundles at the ONH. These results help to validate the relationship between structure and function and may be of use in the further refinement of physiologically derived VF filters to reduce measurement noise.

Glaucoma, Open-Angle↗

Measurement variability in Heidelberg Retina Tomograph imaging of neuroretinal rim area.

PURPOSE: To investigate the optimal frequency of imaging during follow-up to detect glaucoma progression by characterizing variability (noise) in neuroretinal rim area (RA) measured by Heidelberg Retina Tomograph (HRT; Heidelberg Engineering, Heidelberg, Germany). METHODS: RA noise was estimated from patient data and characterized by fitting theoretical distributions to the observed data. Multilevel regression was used to determine factors that significantly affect noise. Computer simulations of disease progression were performed by adding noise generated from the distribution derived from the observed data to the average rate of loss in RA estimated from longitudinal data. Rates of detection of disease progression were investigated for various progression rates, follow-up periods, and rates of imaging. RESULTS: Noise was not normally distributed and was best characterized by the hyperbolic distribution, which fit averages well while allowing for extreme values. Noise was greatly influenced by image quality, but age did not have a significant effect. Rates of detection improved for more frequent imaging, better quality images, and faster rates of disease progression. CONCLUSIONS: Noise in HRT measurement of RA is well characterized by the hyperbolic distribution. Sensitivity of detection improves with more frequent testing, but if consistently poor-quality images are yielded for a patient, the probability of detection is low. Results from this work could be used to tailor individual follow-up patterns for patients with different rates of RA loss and image quality, especially in a clinical trial setting.

Cross-Sectional Studies↗

A new statistical approach for quantifying change in series of retinal and optic nerve head topography images.

PURPOSE: To describe and evaluate new statistical techniques for detecting topographic changes in series of retinal and optic nerve head images acquired by scanning laser tomography (Heidelberg Retinal Tomograph [HRT]; Heidelberg Engineering, Heidelberg, Germany). METHODS: Proven quantitative techniques, collectively referred to as statistic image mapping (SIM), are widely used in neuroimaging. These techniques are applied to HRT images. A pixel-by-pixel analysis of topographic height over time yields a statistic image that is generated by using permutation testing, derives significance limits for change wholly from the patient's own data, and removes the need for reference data sets. These novel techniques were compared to the Topographic Change Analysis (TCA super-pixel analysis) available in the current HRT software, by means of an extensive series of computer experiments. The SIM and TCA techniques were further tested and compared to linear regression of rim area (RA) against time, in real longitudinal HRT series of eyes of 20 normal subjects and 30 ocular hypertensive (OHT) patients that were known to have converted to glaucoma, on the basis of visual field criteria. RESULTS: Computer simulation indicated that SIM has better diagnostic precision at detecting change. In the real longitudinal series, SIM flagged false-positive structural progression in two (10%) of normal subjects, whereas TCA identified three (15%), and linear regression of RA against time identified two (10%). SIM identified 22 (73%) of the OHT converters as having structural progression, whereas the TCA and linear regression of RA against time each identified 16 (53%) over the course of the follow-up. CONCLUSIONS: SIM has better diagnostic precision in detecting change in series of HRT images when compared to current quantitative techniques. The clinical utility of these techniques will be established on further longitudinal data sets.

Adult↗

Vertical diplopia following peribulbar anesthesia: the role of hyaluronidase.

PURPOSE: To estimate the incidence of vertical diplopia following peribulbar anesthesia in otherwise uncomplicated cataract surgery and to establish whether the use of hyaluronidase in the peribulbar injection mixture affected the likelihood of this complication. METHODS: Nine hundred forty consecutive phacoemulsification procedures using peribulbar anesthesia were retrospectively reviewed to identify cases of postoperative vertical diplopia. Case notes were reviewed to establish the nature and timing of the onset of diplopia, the anesthetic technique, and whether hyaluronidase was used. The patterns of progression as demonstrated by serial Hess charts were compared. RESULTS: There were 6 cases of vertical diplopia (incidence, 0.64%). All showed an immediate postoperative hypertropia in the injected eye changing during a 4- to 6-week period to hypotropia with restriction of upgaze. All applications of anesthesia were administered by consultant anesthetists, associate specialists, or residents under their direct supervision using 25-mm, 25-gauge needles with 2% lidocaine. Hyaluronidase was included in the injection mixture for 435 (46%) of the cases and was not included for 505 (54%) of the cases. All 6 cases of vertical diplopia occurred in the group in which hyaluronidase was not used, which has a significant association (chi-square test, 5.22; P = .023). CONCLUSION: Hyaluronidase should be included in peribulbar anesthetics to reduce the risk of postoperative vertical diplopia.

Aged↗