PubMed Health⌕ Search

Biomedical subjects

Nicholas M Selby

Publications and source records attributed to Nicholas M Selby.

8 recordsLinked to original sources

The haemodynamic and metabolic effects of hypertonic-glucose and amino-acid-based peritoneal dialysis fluids.

BACKGROUND: Continuous ambulatory peritoneal dialysis (CAPD) may exert significant effects on systemic haemodynamics. We have previously demonstrated that hypertonic glucose solutions are associated with higher blood pressure (BP) due to a rise in stroke volume (SV) and cardiac output (CO). However, the mechanisms underlying these changes have not been established. METHODS: Ten non-diabetic CAPD patients entered a randomized crossover study (eight completed) to compare conventional glucose-based fluid, biocompatible pH-neutral glucose-based fluid and 1.1% amino acid solution (lactate-buffered but completely free of glucose degradation products). BP and haemodynamic variables were measured using continuous arterial pulse wave analysis, and serial plasma glucose and insulin concentrations were collected. Left ventricular (LV) diameters were measured at the start and end of each dwell period using M-mode echocardiography. RESULTS: BP was similar during 1.36% glucose and 1.1% amino acid dwells, but was significantly higher during 3.86% glucose dwells with both conventional and biocompatible fluids (P < 0.001). This was associated with a significantly higher SV and CO (P < 0.001), although the haemodynamic response differed between conventional and biocompatible 3.86% solutions. Plasma glucose and insulin levels did not differ from baseline during 1.36% and amino acid dwells, but increased significantly during 3.86% glucose dwells. Despite a significantly higher ultrafiltration volume with 3.86% glucose, LV diameters were similar throughout. CONCLUSIONS: In conclusion, we have confirmed our previous findings demonstrating higher BP and adverse haemodynamics during 3.86% glucose dwells. These changes are associated with hyperglycaemia and hyperinsulinaemia, but are not related to differences in cardiac filling.

Adult↗

A systematic review of the clinical effects of reducing dialysate fluid temperature.

BACKGROUND: Intradialytic hypotension (IDH) is a frequent complication of haemodialysis. Reducing the temperature of the dialysis fluid is a simple therapeutic strategy but is relatively underused. This may be due to concerns regarding its effects on symptoms and dialysis adequacy. We performed a systematic review of the literature to examine the effects of cool dialysis on intradialytic blood pressure, and to assess its safety in terms of thermal symptoms and small solute clearance. METHODS: We searched the Cochrane Central Register of Controlled Trials, Medline, Embase, Cumulative Index to Nursing and Allied Health Literature, databases of ongoing trials, the contents of four major renal journals as well as hand-searching reference lists. We included all prospective randomized studies that compared any technique of reducing dialysate temperature with standard bicarbonate dialysis. These techniques included an empirical, fixed reduction of dialysate temperature or use of a biofeedback temperature-control device (BTM) to deliver isothermic dialysis or programmed patient cooling. RESULTS: A total of 22 studies comprising 408 patients were included (16 studies examined a fixed empirical temperature reduction and six examined BTM). All studies were of crossover design and relatively short duration. IDH occurred 7.1 (95% CI, 5.3-8.9) times less frequently with cool dialysis (both fixed reduction and BTM). Post-dialysis mean arterial pressure was higher with cool-temperature dialysis by 11.3 mmHg (95% CI, 7.7-15.0). No studies reported that cool dialysis led to a reduction in dialysis adequacy as assessed by urea clearance. The frequency and severity of thermal-related symptoms were generally reported inadequately. CONCLUSIONS: Reducing the temperature of the dialysate is an effective intervention to reduce the frequency of IDH and does not adversely affect dialysis adequacy. This applies to the fixed reduction of dialysate temperature and BTM. It remains unclear as to what extent cool-temperature dialysis causes intolerable cold symptoms during dialysis. There are no trials comparing fixed empirical temperature reduction with BTM, and no trials examining the long-term effects of cool dialysis on patient outcomes.

Blood↗

Patients receiving maintenance dialysis have more severe functionally significant skeletal muscle wasting than patients with dialysis-independent chronic kidney disease.

BACKGROUND: Chronic renal replacement therapy patients exhibit reduction in skeletal muscle function as a result of a combination of metabolic effects and muscle fibre size reduction. The aim of this study was to compare muscle mass with function in patients with chronic kidney disease (CKD) at stages 4 and 5 on haemodialysis (HD) and peritoneal dialysis (PD), and investigate the associations of muscle wasting in a cross-sectional cohort. METHODS: We studied 134 patients (60 HD, 28 PD and 46 CKD 4). The three groups were well matched for age, sex, diabetes and dialysis vintage. Cross-sectional area (CSA) of muscle and fat was measured from a standardized multi-slice CT scan of a 6 cm long section of thigh. CSA of soft tissue was taken from appropriate fat and muscle densities. Functional assessment was by the sit-to-stand 60 test, assessing both the number of sit-to-stands possible under controlled conditions in 60 s (STS 60), and the time taken to perform five sit-to-stand movements (STS 5). Data were collected on a wide range of potential determinants of muscle CSA. RESULTS: There were no significant differences in haemoglobin between males or females or between any of the groups studied. Serum phosphate and calcium-phosphate product were higher in HD patients as compared to CKD4 patients, but there were no differences in these variables when comparing PD patients with either CKD4 or HD patients. Muscle CSA correlated well with objective functional assessments in males (STS 60 R = 0.52, P<0.0001) and females (R = 0.41, P = 0.004), and STS performance was reduced in dialysed patients as compared with CKD 4. Univariate analysis demonstrated that muscle CSA was associated with serum albumin concentration (R = 0.49, P<0.0001), age (R = -0.35, P = 0.005) and C-reactive protein (R = -0.34, P = 0.004). Creatinine clearance, dialysis adequacy, dialysis vintage and time-averaged serum bicarbonate, calcium and phosphate concentrations were not correlated with muscle CSA. CONCLUSION: In conclusion, patients with dialysis-treated CKD 5 exhibited more functionally significant muscle wasting than patients with CKD 4. This may be amenable to modification with targeted exercise or amelioration of factors associated with observed differences in muscle mass.

Adipose Tissue↗

Occurrence of regional left ventricular dysfunction in patients undergoing standard and biofeedback dialysis.

BACKGROUND: Cardiac failure and cardiovascular death are extremely prevalent in dialysis patients. Recurrent subclinical myocardial ischemia is important in the genesis of heart failure in nondialysis patients. We examined whether this phenomenon occurs in response to the stress of hemodialysis (HD). METHODS: Eight patients prone to intradialytic hypotension were recruited for a randomized crossover study to compare the development of left ventricular regional wall motion abnormalities during standard (HD) and biofeedback dialysis. Patients underwent serial echocardiography with quantitative analysis to assess ejection fraction and regional left ventricular systolic function during both types of dialysis. Blood pressure and hemodynamic variables also were measured by using continuous pulse wave analysis. RESULTS: Forty-two new regional wall motion abnormalities developed in all 8 patients during HD compared with 23 regional wall motion abnormalities that developed in 7 patients during biofeedback dialysis (odds ratio, 1.8; 95% confidence interval, 1.1 to 3.0). The majority of regional wall motion abnormalities showed improvement in function by 30 minutes postdialysis. Overall mean regional function was significantly more impaired during HD (P = 0.022). At peak stress, ejection fraction (measured by percentage of change from baseline) was significantly lower during HD (P = 0.043). Blood pressure was higher during biofeedback dialysis, with significantly fewer episodes of hypotension (odds ratio, 2.0; 95% confidence interval, 1.01 to 4.4). Significantly smaller decreases in stroke volume and cardiac output and a greater increment in pulse rate were observed during biofeedback dialysis. CONCLUSION: This study shows that reversible left ventricular wall motion abnormalities develop during dialysis with ultrafiltration. We also show that this phenomenon can be ameliorated by the improved hemodynamic stability of biofeedback dialysis and therefore is a potential target for intervention.

Aged↗

Hypertonic glucose-based peritoneal dialysate is associated with higher blood pressure and adverse haemodynamics as compared with icodextrin.

BACKGROUND: Little is known about the haemodynamic effects of continuous ambulatory peritoneal dialysis (CAPD) despite its widespread use in the management of end-stage renal failure. We undertook a study to delineate the haemodynamic effects of CAPD using glucose-containing fluids (1.36 and 3.86% glucose) and icodextrin. METHODS: Eight CAPD patients were recruited for a prospective crossover study. Patients attended for two investigatory days (in random order). CAPD was carried out using 1.36% followed by 3.86% glucose (buffered with lactate/bicarbonate, Physioneal) on one study day and 1.36% glucose followed by 7.5% icodextrin (Extraneal) on the other day. Dwell times were 150 min. Blood pressure (BP) and a full range of haemodynamic variables including pulse (HR), stroke volume (SV), cardiac output (CO) and total peripheral resistance (TPR) were measured non-invasively using continuous arterial pulse wave analysis. RESULTS: BP was significantly higher during 3.86% glucose dwells as compared with 1.36% glucose or icodextrin dwells (P<0.0001). TPR during all three dwells was similar; the higher blood pressure was due to an increased HR, SV and, therefore, CO during 3.86% glucose dwells. The higher blood pressure during the 3.86% glucose dwells was present despite the highest ultrafiltration volume and sodium removal. CONCLUSION: This study demonstrates large magnitude haemodynamic changes in response to CAPD. In addition to the well-recognized adverse effects on blood glucose and long-term peritoneal membrane viability, CAPD fluids containing high glucose concentrations may also exert undesirable effects on systemic haemodynamics, with potential long-term consequences for patient outcomes.

Aged↗

Effects of acetate-free double-chamber hemodiafiltration and standard dialysis on systemic hemodynamics and troponin T levels.

Using acetate as a buffer during hemodialysis is recognized to predispose to intradialytic hypotension; however, bicarbonate-based dialysis is not acetate free. Paired hemodiafiltration (PHF) is a novel online acetate-free technique. We investigated whether PHF is capable of abrogating the changes in systemic hemodynamics and troponin T (cTnT) seen with conventional hemodialysis. Twelve patients entered a randomized crossover study. Blood pressure (BP) and a full range of hemodynamic variables were measured throughout PHF and standard dialysis using continuous pulse wave analysis. We also measured predialysis cTnT in 54 stable and unstable dialysis patients. BP was lower during PHF but without increased instability. Stoke volume and cardiac output declined progressively during both treatments but to a much lesser extent during PHF (p = 0.003, p < 0.0001 respectively), whereas peripheral resistance rose to a larger degree during hemodialysis (p < 0.0001). cTnT levels were lower before PHF as compared with hemodialysis (p = 0.023), with levels falling after PHF and rising after hemodialysis (p < 0.0001). In the supplementary patient group, predialysis median serum cTnT was higher in the unstable patients (p = 0.0001). This study demonstrates that PHF (without exposure to acetate) is associated with less deterioration in systemic hemodynamics, maintenance of BP, and less suppression of myocardial contractility as compared with bicarbonate dialysis.

Acetates↗

Automated peritoneal dialysis has significant effects on systemic hemodynamics.

OBJECTIVES: Maintenance of residual renal function (RRF) is an important determinant of outcome in peritoneal dialysis patients. It remains contentious as to whether automated peritoneal dialysis (APD) leads to an increased rate of decline of RRF compared with continuous ambulatory peritoneal dialysis (CAPD). We studied whether APD was associated with significant systemic hemodynamic changes that may play a role in the accelerated loss of RRF. METHODS: As a follow-on from a previous study, 8 well-established CAPD patients underwent a 4-hour APD treatment consisting of 3 drain/fill cycles using 2 x 2.5 L 1.36% glucose and 1 x 3.86% glucose dialysate. Each dwell phase lasted 76 minutes. Blood pressure (BP) and a full range of hemodynamic variables, including pulse (HR), stroke volume (SV), cardiac output (CO), and total peripheral resistance (TPR), were measured noninvasively using continuous arterial pulse wave analysis. RESULTS: BP fell during 2 of the 3 drain/fill periods when dialysate was drained from the peritoneal cavity, but then rose upon instillation of dialysate fluid. The fall in BP was associated with a fall in TPR, matched by an inadequate rise in SV and CO. Over the entire study period, TPR progressively rose to +53.4% above baseline (p = 0.032). Both SV and CO fell over the same period, to -21.1% (p = 0.060) and -22.4% from baseline (p = 0.037) respectively. This did not result in any significant difference between start and end BP. CONCLUSIONS: This study demonstrates that APD is associated with significant systemic hemodynamic effects. The increased number of drain/fill cycles compared to CAPD, or the progressive rise in TPR and reduction in CO (possibly due to a cooling effect), may potentially be factors that adversely affect RRF in APD patients.

Aged↗