PubMed Health⌕ Search

Biomedical subjects

Nicholas Marinakis

Publications and source records attributed to Nicholas Marinakis.

3 recordsLinked to original sources

Changes in aortic root function after valve replacement in patients with aortic stenosis.

BACKGROUND: Aortic elastic properties are compromised in various states that induce functional and histological changes in the aortic wall. Aortic stenosis is frequent and often requires replacement of the stenotic valve. The purpose of this study was to examine the effect of aortic valve replacement on the aortic root function. METHODS: 31 patients, mean+/-SD age 67.2+/-9.1 years with severe aortic stenosis, who underwent aortic valve replacement with a bileaflet mechanical prosthesis, were studied. Aortic root function indices such as aortic cross-sectional compliance (CSC), aortic root distensibility (ARD), and aortic stiffness index (ASI) were calculated with the use of M-mode echocardiography in three sessions: one preoperatively (pre-op), one on day 7 postoperatively (early post-op), and one 6 months postoperatively (late post-op). RESULTS: Aortic root function deteriorated early post-op (p<0.001 for all) and returned towards pre-op levels late post-op (p=NS for all). CSC changed from 2.84+/-1.98 to 1.37+/-0.92, and 2.30+/-1.11 cm2/mmHg, ARD from 2.21+/-5.60 to 1.01+/-0.67, and 1.79+/-0.96 cm2/dyne, and ASI from 9.72+/-5.60 to 24.65+/-19.10, and 11.51+/-7.85, respectively. Correlations were found between early changes in some aortic root indices and the degree of aortic stenosis, denoting that aortic function deteriorated less in more severe cases of aortic stenosis. None of the late changes were related to aortic valve or left ventricular indices. CONCLUSIONS: Aortic valve replacement with a mechanical valve results in a significant but transient impairment of aortic distensibility.

Aged↗

Successful thrombolysis of a partially obstructed bileaflet prosthetic heart valve in the mitral position.

We describe the case of a woman who presented with dyspnea of abrupt onset and who had recently undergone replacement of the mitral valve with a bileaflet mechanical prosthesis. Transthoracic echocardiographic examination with spectral Doppler recording of transvalvular blood flow revealed a velocity spectrum consistent with obstruction. Transesophageal echocardiography demonstrated partial obstruction of the prosthetic valve due to immobilization of 1 hemidisc in the closed position. This immobilization was apparently caused by a small mass whose appearance was consistent with that of a thrombus. The patient was successfully treated by intravenous administration of a thrombolytic agent. This case demonstrates the value of transesophageal echocardiography in the selection of candidates for thrombolytic treatment in cases of thrombosis of a left-sided valve prosthesis.

Aged↗

Embolic stroke after "cured" prosthetic aortic valve endocarditis.

The authors report on the case of a patient with infective endocarditis of a prosthetic valve in the aortic position, after receiving percutaneous transluminal coronary angioplasty. Transesophageal echocardiography provided valuable information about the existence and size of vegetations at the time of initial diagnosis and during followup. Despite successful treatment resulting in good control of the infection and a significant reduction of vegetation size, the patient still suffered a major cerebral embolic event early after hospital discharge.

Aged↗