Nickolay V Lavrik

Publications and source records attributed to Nickolay V Lavrik.

3 recordsLinked to original sources

Detection of anthrax simulants with microcalorimetric spectroscopy: Bacillus subtilis and Bacillus cereus spores.

Recent advances in the development of ultrasensitive micromechnical thermal detectors have led to the advent of novel subfemtojoule microcalorimetric spectoscopy (CalSpec). On the basis of principles of photothermal IR spectroscopy combined with efficient thermomechanical transduction, CalSpec provides acquisition of vibrational spectra of microscopic samples and absorbates. We use CalSpec as a method of identifying nanogram quantities of biological micro-organisms. Our studies focus on Bacillus subtilis and Bacillus cereus spores as simulants for Bacillus anthracis spores. Using CalSpec, we measured IR spectra of B. subtilis and B. cereus spores present on surfaces in nanogram quantities (approximately 100-1,000 spores). The spectra acquired in the wavelength range of 690-4000 cm(-1) (2.5-14.5 microm) contain information-rich vibrational signatures that reflect the different ratios of biochemical makeup of the micro-organisms. The distinctive features in the spectra obtained for the two types of microorganism can be used to distinguish between the spores of the Bacillus family. As compared with conventional IR and Fourier-transform IR microscopic spectroscopy techniques, the advantages of the present technique include significantly improved sensitivity (at least a full order of magnitude), absence of expensive IR detectors, and excellent potential for miniaturization.

Anthrax↗

Studies of the optical properties of metal-pliable polymer composite materials.

Polymer-nano-metallic-particle composites have demonstrated technological potential due to their unique optical and electrical properties. Herein, we report on composites prepared via physical vapor deposition of silver metal onto pliable poly(dimethylsiloxane) (PDMS) polymer. Rapid Ag diffusion and nano-metallic-particle formation in a phase-separated surface layer of the PDMS creates unique sub-surface-based composites whose properties vary based on rate of deposition and average Ag thickness. Additionally, nanometallic-particle spacing can be altered with fair reproducibility and reversibility by physically manipulating the Ag-PDMS composite. The optical properties of the materials are studied by visible wavelength optical extinction spectrometry and surface-enhanced Raman scattering (SERS), including studies performed during physical manipulation. Direct current (DC) conductivity measurements were made during Ag deposition to study percolation conditions for the materials. Depth-profiling was performed by X-ray photoelectron spectrometry. Sample Raman spectral data collected with the composite as a SERS substrate are included. A practical technological characteristic of these composite materials arises from their potential to be molded into functional devices.

Coated Materials, Biocompatible↗

Nanostructured microcantilevers with functionalized cyclodextrin receptor phases: self-assembled monolayers and vapor-deposited films.

It is shown that the performance of microcantilver-based chemical sensors in a liquid environment is affected by altering cantilever surface morphology and receptor phase type and thickness. Self-assembled monolayers of thiolated beta-cyclodextrin (HM-beta-CD) and thin films of vapor-deposited heptakis (2,3-O-diacetyl-6-O-tertbutyl-dimethylsilyl)-beta-cyclodextrin (HDATB-beta-CD) were studied on smooth and nanostructured (dealloyed) gold-coated microcantilever surfaces. The dealloyed surface contains nanometer-sized features that enhance the transduction of molecular recognition events into cantilever response, as well as increase film stability for thicker films. Improvements in the limits of detection of the compound 2,3-dihydroxynaphthalene as great as 2 orders of magnitude have been achieved by manipulating surface morphology and film thickness. The observed response factors for the analytes studied varied from 0.02-604 nm/ppm, as determined by cantilever deflection. In general, calibration plots for the analytes were linear up to several hundred nanometers in cantilever deflections.