PubMed Health⌕ Search

Biomedical subjects

Nicola De Zanche

Publications and source records attributed to Nicola De Zanche.

4 recordsLinked to original sources

Potential and feasibility of parallel MRI at high field.

This survey focuses on the fusion of two major lines of recent progress in MRI methodology: parallel imaging with receiver coil arrays and the transition to high and ultra-high field strength for human applications. As discussed in this paper, combining the two developments has vast potential due to multiple specific synergies. First, parallel acquisition and high field are highly complementary in terms of their individual advantages and downsides. As a consequence, the joint approach generally offers enhanced flexibility in the design of scanning strategies. Second, increasing resonance frequency changes the electrodynamics of the MR signal in such a way that parallel imaging becomes more effective in large objects. The underlying conceptual and theoretical considerations are reviewed in detail. In further sections, technical challenges and practical aspects are discussed. The feasibility of parallel MRI at ultra-high field is illustrated by current results of parallel human MRI at 7 T.

Algorithms↗

Analytical approach to noncircular section birdcage coil design: verification with a Cassinian oval coil.

A general analytical framework is presented for the design of birdcage radiofrequency resonators on cylindrical formers having arbitrary cross-sectional shape. The primary objective of such shapes would be to improve the sensitivity of the NMR experiment to noncircular regions of the human anatomy while maintaining field homogeneity and quadrature polarization comparable to those of standard circular birdcage coils. The shape of the corresponding radiofrequency screen, which is required to decouple the coil from the rest of the NMR system and which is key to the performance, is also provided by this methodology. The theory was tested by constructing a 3-T, quadrature, proton coil on a shape conforming to the anthropomorphic mean of the human head, namely, the oval of Cassini. Both bench tests (Q) and in vivo spectral and imaging comparisons of the Cassinian coil with an equivalently dimensioned and constructed circular birdcage coil, respectively, predicted and demonstrated in vivo an improvement in SNR of approximately 24% over the circular section coil. The experimental RF field homogeneity and quadrature performance were comparable for both coil geometries, with the circular coil being marginally superior.

Equipment Design↗

Parallel imaging performance as a function of field strength--an experimental investigation using electrodynamic scaling.

In this work, the dependence of parallel MRI performance on main magnetic field strength is experimentally investigated. Using the general framework of electrodynamic scaling, the B0-dependent behavior of the relevant radiofrequency fields at a single physical field strength of 7 T is studied. In the chosen implementation this is accomplished by adjusting the permittivity and conductivity of a homogeneous spherical phantom. With different mixing ratios of decane, ethanol, purified water, N-methylformamide, and sodium chloride, field strengths in the range of 1.5 to 11.5 T are mimicked. Based on sensitivity maps of an eight-coil receiver array, the field-dependent performance of parallel imaging is assessed in terms of the geometry factor g, which reflects noise enhancement in parallel imaging reconstruction. At low field strengths the SNR penalty was nearly independent of B0 and favorably low for 1D reduction factors up to between 3 and 4. At higher field strengths the transition between favorable and prohibitive parallel imaging conditions was found to shift toward higher feasible reduction factors. These findings are in good agreement with previous theoretical predictions. From this agreement it is concluded that parallel MRI at high B0 benefits specifically from onsetting far-field behavior of the involved radiofrequency fields.

Electromagnetic Fields↗

Sensitivity calculations and comparisons for shielded elliptical and circular birdcage coils.

An analytical framework is presented which justifies the use of a confocal elliptical shield (previously adopted on empirical or numerical grounds) to limit the spatial extent of the radiofrequency (RF) field produced by an elliptical birdcage coil, while concurrently minimizing field inhomogeneities. From this analytical capability it is further shown that the relative linear mode geometric sensitivities depend only on the shield dimensions and can be readily evaluated, thus providing an upper bound to the improvement in signal-to-noise ratio (SNR) of the damped elliptical birdcage over a circular coil of similar dimensions. The mismatch in the linear mode sensitivities can also be evaluated, and a method for the design of an appropriate feed configuration that ensures quadrature operation is given.

Artifacts↗