Functionalized magnetic micro- and nanoparticles: optimization and application to micro-chip tryptic digestion.

The preparation of an easily replaceable protease microreactor for micro-chip application is described. Magnetic particles coated with poly(N-isopropylacrylamide), polystyrene, poly(2-hydroxyethyl methacrylate-co-ethylene dimethacrylate), poly(glycidyl methacrylate), [(2-amino-ethyl)hydroxymethylen]biphosphonic acid, or alginic acid with immobilized trypsin were utilized for heterogeneous digestion. The properties were optimized, with the constraint of allowing immobilization in a microchannel by a magnetic field gradient. To obtain the highest digestion efficiency, sub-micrometer spheres were organized by an inhomogeneous external magnetic field perpendicularly to the direction of the channel. Kinetic parameters of the enzyme reactor immobilized in micro-chip capillary (micro-chip immobilized magnetic enzyme reactor (IMER)) were determined. The capability of the proteolytic reactor was demonstrated by five model (glyco)proteins ranging in molecular mass from 4.3 to 150 kDa. Digestion efficiency of proteins in various conformations was investigated using SDS-PAGE, HPCE, RP-HPLC, and MS. The compatibility of the micro-chip IMER system with total and limited proteolysis of high-molecular-weight (glyco)proteins was confirmed. It opens the route to automated, high-throughput proteomic micro-chip devices.

Amyloid beta-Peptides↗

In-capillary non-covalent labeling of insulin and one gastrointestinal peptide for their analyses by capillary electrophoresis with laser-induced fluorescence detection.

The potential of the commercially available dye sypro orange for in-capillary derivatization was evaluated for the detection of insulin and one gastrointestinal peptide (Arg-Arg-gastrin) by capillary electrophoresis with laser induced fluorescence (CE-LIF). The fluorescent emission intensity (lambda(ex) = 488 nm, lambda(em) = 610 nm) of this probe is very low in aqueous medium, and increases strongly in less polar solvent, e.g. methanol. The hydrophobic character of the two analyzed peptides is too low to induce sufficient interaction with the fluorescent probe for good sensitivity when the latter is alone in the background electrolyte. Thus, the potential of several neutral, zwitterionic, cationic and anionic surfactants to favor probe/peptide interactions has been evaluated. It was demonstrated that a borate buffer (pH 8.5) containing tetradecyltrimethylammonium bromide (TTAB) in sub-micellar conditions can be considered as the most suitable buffer for insulin CE-LIF analysis. In addition, the method showed a good linearity between insulin concentration and the peak area of the labeled insulin, allowing quantitative measurements. The sensitivity achieved so far is comparable with that achieved with UV absorption detection, but even at this level it is interesting for microchip analysis, in which fluorescence detection is much more commonly available than UV absorption detection.

Electrophoresis, Capillary↗

Use of self assembled magnetic beads for on-chip protein digestion.

The use of grafted trypsin magnetic beads in a microchip for performing protein digestion is described. The PDMS device uses strong magnets to create a magnetic field parallel to the flow with a strong gradient pointing through the center of the chip channel. This allows for the formation of a low-hydrodynamic resistance plug of magnetic trypsin beads that serves as a matrix for protein digestion. This device represents an inexpensive way of fabricating a multi open-tubular-like column with an appropriate pore size for proteins. Kinetics studies of the hydrolysis of a model peptide show a 100-fold increase in digestion speed obtained by the microsystem when compared to a batch wise system. This system also offers the great advantage of easy replacement, as the bead matrix is easily washed out and replaced. High performance and reproducibility for digesting recombinant human growth hormone are confirmed by analysing the digest products in both CE and MALDI-TOF MS. Similar sequence coverage (of about 44%) is obtained from MS analysis of products after 10 minutes on-chip and 4 h with soluble trypsin in bulk.

Dimethylpolysiloxanes↗

Non-markovian transport of DNA in microfluidic post arrays.

We present an analytically solvable model for the transport of long DNA through microfluidic arrays of posts. The motion is a repetitive three-part cycle: (i) collision with the post and extension of the arms; (ii) rope-over-pulley post disengagement; and (iii) a random period of uniform translation before the next collision. This cycle, inspired by geometration, is a nonseparable (Scher-Lax) continuous-time random walk on a lattice defined by the posts. Upon adopting a simple model for the transition probability density on the lattice, we analytically compute the mean DNA velocity and dispersivity in the long-time limit without any adjustable parameters. The results compare favorably with the limited amount of experimental data on separations in self-assembled arrays of magnetic beads. The Scher-Lax formalism provides a template for incorporating more sophisticated microscale models.

Bacteriophage T4↗

Motion of single long DNA molecules through arrays of magnetic columns.

We present a videomicroscopy study of T4 DNA (169 kbp) in microfluidic arrays of posts formed by the self-assembly of magnetic beads. We observe DNA moving through an area of 10 000 microm(2), typically containing 100-600 posts. We determine the distribution of the contact times with the posts and the distribution of passage times across the field of view for hundreds of DNA per experiment. The contact time is well approximated by a Poisson process, scaling like the inverse of the field strength, independent of the density of the array. The distribution of passage times allows us to estimate the mean velocity and dispersivity of the DNA during its motion over distances long compared to our field of view. We compare these values with those computed from a lattice Monte Carlo model and geometration theory. We find reasonable quantitative agreement between the lattice Monte Carlo model and experiment, with the error increasing with increasing post density. The deviation between theory and experiment is attributed to the high mobility of DNA after disengaging from the posts, which leads to a difference between the contact time and the total time lost by colliding. Classical geometration theory furnishes surprisingly good agreement for the dispersivity, while geometration theory with a mean free path significantly overestimates the dispersivity.

Bacteriophage T4↗

Utilization of newly developed immobilized enzyme reactors for preparation and study of immunoglobulin G fragments.

The newly developed immobilized enzyme reactors (IMERs) with proteolytic enzymes chymotrypsin, trypsin or papain were used for specific fragmentation of high molecular-mass and heterogeneous glycoproteins immunoglobulin G (IgG) and crystallizable fragment of IgG (Fc). The efficiency of splitting or digestion were controlled by RP-HPLC. The specificity of digestion by trypsin reactor was controlled by MS. IMERs (trypsin immobilized on magnetic microparticles focused in a channel of magnetically active microfluidic device) was used for digestion of the whole IgG molecule. The sufficient conditions for IgG digestion in microfluidic device (flow rate, ratio S:E, pH, temperature) were optimized. It was confirmed that the combination of IMERs with microfluidic device enables efficient digestion of highly heterogeneous glycoproteins such as IgG in extremely short time and minimal reaction volume.

Amino Acid Sequence↗

Quantitative microfluidic separation of DNA in self-assembled magnetic matrixes.

We present an experimental study of the microfluidic electrophoresis of long DNA in self-assembling matrixes of magnetic bead columns. Results are presented for the rapid separation of lambda-phage, 2lambda-DNA, and bacteriophage T4 DNA, where separation resolutions greater than 2 between lambda and T4 are achieved in times as short as 150 s. The use of a computer-piloted flow control system and injection results in high reproducibility between separations. We compare the experimentally measured mobility and dispersion with an exactly solvable lattice Monte Carlo model. The theory predicts that the mean velocity scales linearly with the field, the band broadening scales with the inverse of the field, and the resolution is independent of the field for intermediate fields-all of which are in accord with the experimental results. Moreover, reasonable quantitative agreement is achieved for band broadening for longer DNA (2lambda and T4) when the average postengagement time is measured experimentally. This work demonstrates the possibility of achieving fast microfluidic separation of large DNA on a routine basis.